8
4. Peel off the protective foil from the insulation, apply the self-adhesive annuluses
around the openings for connections. Some annuluses are cut out, these shall be
used in places where openings are close to each other (the annuluses overlap).
5. Fit the assembly with elbow ball valve (code 12690). From this point
on, it is important to stick to the sequence of installation steps
described below!
6. Fit the assembly with ball valve and pressure gauge (code 12689).
7. Do hrdla 1“ pod skupinu s manometrem namontovat zátku (kód 7691).