background image

www.regulus.eu

HSK PV

HSK PV

EN

Installation and Operation Instructions

THERMAL STORES with stainless-steel DHW tube heat exchanger

 HSK 600 PV, HSK 750 PV, HSK1000 PV, HSK 1700 PV

Summary of Contents for HSK 1000

Page 1: ...www regulus eu HSK PV HSK PV EN Installation and Operation Instructions THERMAL STORES with stainless steel DHW tube heat exchanger HSK 600 PV HSK 750 PV HSK1000 PV HSK 1700 PV ...

Page 2: ...ion 3 1 4 Packaging 3 2 General Information 3 3 Technical Data and Dimensions of HSK PV Model Line 4 4 Operation 12 5 Typical Layout Examples with Thermal Store 12 6 Installation and Commissioning 13 7 Installing Insulation on the Tank 13 8 Maintenance 15 9 Disposal 15 10 Warranty 15 ...

Page 3: ...nsulation shall not be fitted on the tank until it reaches its definite place of installation This is a fleece insulation 100 mm thick with a hard polystyrene surfa ce It is closed by quick locks 1 4 Packaging Thermal stores are delivered standing each screwed to its pallet packed in bubble wrap It is forbidden to transport and or store the thermal stores in a horizontal position 2 General Informa...

Page 4: ...ume 557 l Fluid volume in tank 525 l Fluid volume above the separating plate 235 l Fluid volume below the separating plate 290 l Upper DHW heat exchanger volume 21 l Lower DHW heat exchanger volume 11 l DHW heat exchanger surface area 6 m2 Plocha výměníku TV pod dělicím plechem 3 m2 Max working temperature in Thermal Store 95 C Max working temperature in DHW HE 95 C Max working pressure in Thermal...

Page 5: ...nts E1 Electric heating element for DHW heating G 6 4 F 1150 E2 Electric heating element for space heating G 6 4 F 1890 E3 Electric heating element for space heating G 6 4 F 1890 E4 Electric heating element for PV system G 6 4 F 1310 DHW heating W1 Cold water G 1 M 4 1285 W2 Hot water G 1 M 4 1110 W3 Circulation G 1 M 4 1110 W4 Hot water G 1 M 4 1970 Control and safety C1 Temperature sensor G 1 2 ...

Page 6: ...chnical Data Total tank volume 757 l Fluid volume in tank 725 l Fluid volume above the separating plate 304 l Fluid volume below the separating plate 421 l Upper DHW heat exchanger volume 21 l Lower DHW heat exchanger volume 11 l DHW heat exchanger surface area 6 m2 Plocha výměníku TV pod dělicím plechem 3 m2 Max working temperature in Thermal Store 95 C Max working temperature in DHW HE 95 C Max ...

Page 7: ...nts E1 Electric heating element for DHW heating G 6 4 F 1175 E2 Electric heating element for space heating G 6 4 F 1915 E3 Electric heating element for space heating G 6 4 F 1915 E4 Electric heating element for PV system G 6 4 F 1310 DHW heating W1 Cold water G 1 M 4 1295 W2 Hot water G 1 M 4 1135 W3 Circulation G 1 M 4 1135 W4 Hot water G 1 M 4 1995 Control and safety C1 Temperature sensor G 1 2 ...

Page 8: ...hnical Data Total tank volume 922 l Fluid volume in tank 890 l Fluid volume above the separating plate 314 l Fluid volume below the separating plate 576 l Upper DHW heat exchanger volume 21 l Lower DHW heat exchanger volume 11 l DHW heat exchanger surface area 6 m2 Plocha výměníku TV pod dělicím plechem 3 m2 Max working temperature in Thermal Store 95 C Max working temperature in DHW HE 95 C Max w...

Page 9: ...ents E1 Electric heating element for DHW heating G 6 4 F 1365 E2 Electric heating element for space heating G 6 4 F 1110 E3 Electric heating element for space heating G 6 4 F 1110 E4 Electric heating element for PV system G 6 4 F 1300 DHW heating W1 Cold water G 1 M 4 1300 W2 Hot water G 1 M 4 1360 W3 Circulation G 1 M 4 1360 W4 Hot water G 1 M 4 1220 Control and safety C1 Temperature sensor G 1 2...

Page 10: ...echnical Data Total tank volume 1684 l Fluid volume in tank 1652 l Fluid volume above the separating plate 550 l Fluid volume below the separating plate 1102 l Upper DHW heat exchanger volume 21 l Lower DHW heat exchanger volume 11 l DHW heat exchanger surface area 6 m2 Plocha výměníku TV pod dělicím plechem 3 m2 Max working temperature in Thermal Store 95 C Max working temperature in DHW HE 95 C ...

Page 11: ...ents E1 Electric heating element for DHW heating G 6 4 F 1437 E2 Electric heating element for space heating G 6 4 F 1170 E3 Electric heating element for space heating G 6 4 F 1170 E4 Electric heating element for PV system G 6 4 F 1335 DHW heating W1 Cold water G 1 M 4 1335 W2 Hot water G 1 M 4 1390 W3 Circulation G 1 M 4 1390 W4 Hot water G 1 M 4 1240 Control and safety C1 Temperature sensor G 1 2...

Page 12: ...awn from the outlet point cold water flows into the immersed heat exchanger and heats up by the heating water The thermal store shall be connected to heat sources through connecting threaded fittings Individual connection points are assigned according to the circuits to be connected There is a wide choice of combi nations the following chapter describes just some examples 5 Typical Layout Examples...

Page 13: ... Commissioning The tank shall be filled up together with the heating system respecting valid standards and rules In order to minimize corrosion special additives for heating systems should be used The quality of heating water depends on the quality of filling water at commissioning on the top up water and on the frequency of topping up This has a strong influence on the lifetime of heating systems...

Page 14: ...cover 6 Push on the covering plastic rosettes depending on the size of tappings or put on the flange plug s with insulation 7 Finish the tank installation in compliance with the respective instructions and valid standards and rules Warranty on insulation Warranty shall become null and void if the procedure described in the Installation Manual was not respected the product was used for other purpos...

Page 15: ...osed of in compliance with the valid rules When the product reaches the end of its life it shall not be disposed of as household waste It shall be dropped off at a Local Waste Recycling Center Insulation shall be recycled as plastic and the steel vessel as scrap iron 10 Warranty This product is covered by warranty under conditions specified in this Manual and the respective Warranty Certificate Th...

Page 16: ... 2022 We reserve the right to errors changes and improvements without prior notice REGULUS spol s r o E mail sales regulus eu Web www regulus eu v1 3 07 2022 ...

Reviews: