Precautions of use

Security

Returning 

-

 Make sure that 240V 50 Hz the supply 

voltage  does  not  exceed

 

240VAC-

50Hz.

- If liquid or any object enters the control 

box,  unplug  the  unit  and  have  it 
checked  by  a  qualified  technician 
before returning it o service.

- Prohibition of drilling the control box

The  filtration  cabinet  must  be  in  the 
vicinity  of  the  device  and  be  easy  to 
access.

After  switching  off  the  appliance  with 

the  ON/OFF  switch,  do  not  open  the 
a p p l i a n c e   u n t i l   t h e   l i g h t s   h a v e 
completely extinguished.

Do  not  store  chemical  cans  near  the 

appliance.

-  Retain  the  original  packing  carton 
and  packing  material.  They  will  be 
very useful if you ever need to ship the 
unit.
-  To  ensure  maximum  protection, 
repack  the  unit  as  it  was  factory 
packaged.

- The Bulleur is an electronic device and must 
not be exposed to rain or moisture.
-  The  technical  room  must  be  properly 
ventilated.
-  The  power  supply  must  be  protected 
upstream  by  a  30  mA  differential  circuit-
breaker.
- In order to avoid any risk of electric shock, 
open the cabinet only for its installation or a 
service intervention (to change an electronic 
card) after having cut off the power supply.

Advice

 

R e g u l '   e l e c t r o n i q u e 

designs and manufactures in 

its workshops, in France, all 
i t s   p r o d u c t s   o f   s a l t 

electrolyse,  pH  regulation  and 
regulation of water level.

Warranty

 

- You have just purchased a Regul' 
Electronique,  we  thank  you  for 
your confidence.
-  Unless  otherwise  specified  ,the 
warranty period for our products is 
3  years  from  the  date  of  your 

invoice.
- Excluded from the warranty are any so-called 
wear  parts(fuses,batteries,seals,air  tube, 
valves, pump membranes, etc).
- This guarantee is limited to the supplies of 
our company. It consists in the repair, by our 
care,  and  in  our  workshops,  defects  or 
manufacture  and  matter,  that  the  customer 
must prove.
-  The  equipment  must  be  returned  free  of 
postage.  The  costs  of  removal,  rest  and 
transport  are  excluded  from  the  guarantee.
- In all cases, our responsability is limited to 
the replacement of the defective parts, without 
any compensation or damage and interest can 
be claimed for any damage caused(physical 
etc..).
-  The  guarantee  ceases  when  our  materials 
are modified outside our workshops.
- The warranty does not apply to replacements 
or  repairs  that  result  from  normal  wear  and 
tear  of  equipment,  damage  or  accidents 
resulting from negligence, faulty monitoring or 
maintenance,  improper  installation  or  use 
abnormal devices.
-  In  the  case  of  inadequate  treatments  and 
adjustments  we  cannot  be  held  liable,  in 
particular in the case of corrosion and defects 
due to excessively high operating stresses or 
if the equipment must therefore be operated at 
high speeds too sustained.

 2

Summary of Contents for Bulleur

Page 1: ...DESIGNED AND MANUFACTURED IN FRANCE SINCE 1989 16012019 INSTRUCTIONS INSTALLING Peace of mind Bulleur Water level regulation for overflow pools Bulleur ...

Page 2: ...o d u c t s o f s a l t electrolyse pH regulation and regulation of water level Warranty You have just purchased a Regul Electronique we thank you for your confidence Unless otherwise specified the warranty period for our products is 3 years from the date of your invoice Excluded from the warranty are any so called wear parts fuses batteries seals air tube valves pump membranes etc This guarantee ...

Page 3: ...ng to measure a heigh of water of 2 50 m A measuring rod made up of 3 PVC tubes 20 mm in diameter and 42 cm in length If necessary the measuring rod can be extended by a PVC tube with a diameter of 20mm An intermittent 240 V membrane compressor An electronic board protected by a 200 mA fuse A 315 mA fuse protection of the solenoid control transformer A led flashes to indicate that it is faulty pre...

Page 4: ...4 ...

Page 5: ...raulic installation 10 3 Configuration Menu Configuration 11 4 Calibration of thresholds Schematic diagram 12 Functionality of each threshold 13 Calibration of levels 14 6 Additional displays Additional displays 15 The Configuration menu is used to select the active functions of the Bulleur Le Calibration menu makes it possible to choose the water levels for each threshold Normal displays and indi...

Page 6: ...ions 1 x cap for measuring rod 2 x sleeves of 20 mm to stick 3 x tubes of measuring rods PVC of 20 mm to stick length 420 mm 2 x PVC clips and 2x stainless steel screws fixation of the measuring rod in the buffer tank 25 m bubble tube 4 6 mm 1 x RAINBIRD DV 100 solenoid valve 4 x screws and fixing pins of the control box ...

Page 7: ...d Operating controls button clic clic 2 A 2 sec click to modify a data item A short click to validate click A click to enter the configuration menu p11 to decrease or increase a value The control knob allows by pressing to change the displayed value to enter certain menus and by rotating to modify a stored value Off On to validate a function N1 à x cm to choose a value Solenoid valve Power supply ...

Page 8: ...nting template to facilitate the installation 4 fixing holes make it possible to assemble the assembly Mark the location of the holes using a level 6 mm holes for the provided pegs 1 Installating the device 2x stainless screws 4x35mm Accessories required for wall mounting are supplied 2x anchors diam 6mm Whenever possible use the materials provided they have been chosen for their qualities stainle...

Page 9: ...ontact Disconnect the wire connected to the filter clock contact Connect one of the wires to this contact and then the other by a quick connection on the left wire In contrast to the filtration force for safety reasons it is necessary to be able to stop the filtration in particular when the level is too low M horloge Horloge de Filtration M horloge Horloge de Filtration Connecting the electro valv...

Page 10: ...ull Slight bias cut The tube must descend to the bottom of the cane Connect the 4 x 6 mm tube between the box and measuring rod The tube must go down inside the tube to the bottom of the rod The gland only serves to hold the tube in the measuring rod This is the place where the bubbles come out as the measurement is made ...

Page 11: ...ify a data a single click to validate then appears on the screen Security filling to exit the menu switch off the device factory setting 1h Security filling N2 STOP Configuration from off to 3hours 30 min steps security after reaching N3 stopping the filtering force at the end of the set tempo filtration is restarted for 15 min every 60 min flashes Return Warning OFF makes it possible not to take ...

Page 12: ...sation Level is going down filtration force Autorization of filtration Stop drain Filling Level 1 N1 Level 2 N2 security level Filling Stop filtration Schematic diagram Emptying Emptying Tempo rain 4 Calibration of thresholds Security filling of 30mn until 3h 12 Emptying Stop fillinf below 5 cm ...

Page 13: ... in auto mode of filtration after the rain tempo Level N3 Level filtration force as the level rises above if the tempo rain is chosen in configuration menu the force filtration stops at the end of it it is restarted for 15 min every 60 min to avoid a reset in manual way by emptying backwashing etc Level emptying appears only if the function is selected in the configuration menu Controls a drain pu...

Page 14: ...eshold stop filling stop drain N1 x cm N1 S Calibration flashes clic 2 N2 stop filling Set the desired level it is adjustable from the previous level to the chosen level Calibration Calibration Calibration clic Level N3 Threshold force filtration N2 x cm N1 S Calibration flashes clic 2 N3 force filtration Set the desired level it is adjustable from the previous level to the chosen level clic Level...

Page 15: ...ntil it disappears TEMPO RAIN TEMPO PLUIE setting from OFF to 3h see page 12 The level N3 can be reached during a heavy rain the filtration is then forced down again below N3 little chance in case of heavy rain the time delay then makes it possible to stop the filtration force at the end of it in order to return to self filtration mode and to prevent the filtration pump from continuously operating...

Page 16: ......

Reviews: