RA67
IN-LINE ACTUATOR SERIES
9
CAUTION!
• Mounting pins must have the correct dimensions
and limited free play.
• Any bolts and nuts used for the installation must
be made of high-quality steel.
• Do not apply an excessive torque on the mounting
bolts to avoid stressing the fixtures.
WARNING!
If the actuator is used in an application that may
cause personal injury, it is the responsibility of the
application manufacturer to introduce the necessary
safety measures to prevent personal injury in case
of failure.
WARNING!
REGNER® actuators are not designed to be used in
the following applications: aircraft, explosive envi-
ronments, nuclear power generators, and offshore
installations.
Electrical Installation
• Voltage must be switched off when installing anc
connecting the actuator.
• Make sure that the power supply and the cables
can handle the maximum motor current.
• The electronic limit switches will automatically
switch off the actuator when the rod reaches the
ends of the stroke or if an excessive load occurs
mid-stroke.
• Connect the actuator using the right counterpart
connectors in your application.
Power supply
Inconnect D50754 IPG-8202-PS
1. Motor -
2. Motor +
1
2
Position feedback
Molex 43025-0400
1. -
2. Feedback Signal
3. Feedback 5 VDC
4. Feedback 0 VDC
1
2
3
4
CAUTION!
• Make sure the leads and cables leading to the
motor can handle the maximum motor current.
• For additional protection, use a fuse between the
actuator and the power source.
• Do not work on the actuator or the wiring with the
power switched on!
Hall Potentiometer position feedback
• The potentiometer may operate with voltages up
to 5 VDC. Do not use a higher voltage.
• Standard output: Analog output 0.3 - 3.0 VDC ±
3%.