background image

Regency  Z2510  WarmHearth

23

WARRANTY

Regency Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects
each unit thoroughly before it leaves our door.  Regency Industries Ltd. is pleased to extend this limited lifetime warranty to the  original purchaser
of a Regency Product. This warranty is not transferable.

The Warranty:  Lifetime
Covered under the agreement are the following  components:

Firebox, ceramic baffle, vermiculite baffle, convector airmate, castings, ashdrawer, glass (thermal breakage) gold plating (against defective manufacture),
airtubes (against warpage) and door handles.

Special Finishes - One year on brushed nickel, louvers and doors. You can expect some changes in color as the product "ages" with constant heating
and cooling. FPI warranties the product for any manufacturing defects on the original product. However, the manufacturers warranty does not cover
changing colors and marks, ie. finger prints, etc applied after the purchase of the product. Damage from the use of abrasive cleaners is not covered
by warranty.

The above will be covered for parts and subsidized labour for the first five years and parts only thereafter with the exception of the fireboxes (see below).

FPI is not liable for freight or labor on any wood burning appliance replaced in field.

Electrical components such as blowers, switches and thermodisc's are covered for one year from the date of purchase.

Conditions:
Any part or parts of this unit which in our judgement show evidence of such defects will be repaired or replaced at Regency's option, through an accredited
distributor or agent provided that the defective part be returned to the distributor or agent Transportation Prepaid, if requested.

It is the general practice of FPI to charge for larger, higher priced replacement parts and issue credit once the replaced component has been returned
to FPI and evaluated for manufacturer defect.

The authorized selling dealer is responsible for all in-field service work carried out on your Regency product. FPI will not be liable for results or costs
of workmanship from unauthorized service persons or dealers.

At all times FPI reserves the right to inspect product in the field which is claimed to be defective.

All claims must be submitted to FPI by authorized selling dealers. It is essential that all submitted claims provide all of the necessary information including
customer name, purchase date, serial #, type of unit, problem, and part or parts requested, without this information the warranty will be invalid.

Exclusions:
This limited Lifetime Warranty does not extend to or include paint, door or glass gasketing, firebrick or trim. It does not cover installation and operational
related problems such as over-firing, use of corrosive driftwood, downdrafts or spillage caused by environmental conditions, nearby trees, buildings,
hilltops, mountains, inadequate venting or ventilation, excessive offsets, negative air pressures caused by mechanical systems such as furnaces, fans,
clothes dryers etc.

At no time will FPI be liable for any consequential damages which exceed the purchase price of the unit. FPI has no obligation to enhance or modify
any unit once manufactured. ie. as products evolve, field modifications or upgrades will not be performed.

FPI will not be liable for travel costs for service work.

Installation and environmental problems are not the responsibility of the manufacturer and therefore are not covered under the  terms of this warranty
policy.

Any unit which shows signs of neglect or misuse is not covered under the terms of this warranty policy.

The warranty will not extend to any part which has been tampered with or altered in any way, or in our judgment has been subject  to misuse.

Freight damage to stoves and replacement parts is not covered by warranty and is subject to a claim against the freight carrier by the dealer.

FPI will not be liable for acts of God, or acts of terrorism, which cause malfunction of the appliance.

Performance problems due to operator error will not be covered by this warranty policy.

Products made or provided by other manufacturers and used in conjunction with the operation of this appliance without prior authorization from Regency,
may nullify your warranty on this product.

* Subsidy according to job scale as predetermined by FPI.

Summary of Contents for Z2510L

Page 1: ...arth High Efficiency EPA Certified Fireplace MODEL Z2510L WarmHearth Fireplace Owners Installation Manual 10 06 04 Tested by Installer Please complete the details on the back cover and leave this manual with the homeowner Homeowner Please keep these instructions for future reference www regency fire com ...

Page 2: ... you years of trouble free enjoyment This product has been certified by the Environmental Protection Agency of the United States Thismeansthatitmeetsthestricteststandardsinprovidingyouwiththelatestincleanburning technologyandefficiency Specificationsmayvarywidely ConsultwithyourRegencyDealerforlocal considerations Keep those REGENCY FIRES burning ...

Page 3: ...ling the Outside Air Kit 13 Wiring the WarmHearth 13 Installing the Blower Systems 13 Fan Part Numbers 13 1 Internal Blower with Thermodisc 14 2 External Blower with Thermodisc 14 3 Internal External Blower with Thermodisc 14 Gravity Air Feed Option 14 Installing Your Central Heating System 15 Materials Required 15 Installation 15 Finishing the WarmHearth Completing the Facing 17 Non Self Supporti...

Page 4: ...each Regency WarmHearth It is located inside the lower louver opening on the left side We have printed a copy of the contents here for your review SAFETY LABEL NOTE Regency units are constantly being improved Check the label on the unit and if there is a difference the label on the unit is the correct one ...

Page 5: ... inch Flue Pipe 12 HighHeatRefractoryLining PRODUCT DETAILS EPA Certified YES Phase 2 Emissions 5 2 Gms Hr Efficiency DEQ 70 7 BTU HR EPA 10 600 39 500 Flue Size 7 diameter or 8 with Adaptor 000 924 Log Size 22 Weight shipping 715 lbs stripped weight 460 lbs INSTALLATION OPTIONS Blower 150 CFM 2 speed Central Forced Air 433 CFM Blower Heating System Gold Door 24 kt Gold Plated Gold Louvers 24 kt G...

Page 6: ...ulting in serious injury and or property damage 2 Always check your local building codes The installation must comply with all local regional and state codes and regulations 3 This model fireplace must be installed with one of the chimney systems listed in the Chimney Section in this manual These systems are intended for use as a residen tial type appliance The chimney must always vent to the outs...

Page 7: ...9 A Furnace Damper Control optional 10 The Masonry Retainer Kit Optional 11 Furnace Blower optional CLEARANCES AND HEIGHT REQUIREMENTS The WarmHearth may be placed on or near construction materials The combustion air kit fire stop spacer and roof flashings not chase flashings may be placed directly on or against NOTE 1 Do not insulate the chase cavity with blown or fill type insulation materials 2...

Page 8: ...place above the floor a Z type safety strip should be fabricated from 20 gauge galvanized sheet steel and used to protect the front surface of the wood INSTALLATION FRAMING DETAILS Note Ducting is tested at 1 in clearance to framing for the first 6 feet and 1 2 in thereafter and no stand offs are required LOCATION OF FIREPLACE Carefully select the proper location for heat circulation aesthetics ch...

Page 9: ...ledcloserthanthefireplaceout side facing spacers 3 Fireplace must be anchored to the framing to prevent movement or rocking use wall grips or seismic brackets which have been supplied Theseanglebracketsareinstalled by attaching them to the side of the unit and to the back side of the 2 x 4 or further back on 2 x 6 framing CHIMNEY SYSTEM CONSIDERATIONS Regency s WarmHearth Fireplace is to be in sta...

Page 10: ...ual taste See Pages 17 to 18 10 Position masonry liner bricks and ceramic fiber insulation in the unit Attach gold louvers glass door spring handles See Page 19 INSTALLING THE STAND OFFS Stand offs are installed to provide reduced temperatures and proper clearances for the safe installation of your product They consist of four 1 in stand offs on the back two 2 in stand offs on each side and one 6 ...

Page 11: ...mes and excessive heat output The chimney must extend at least 3 ft above its point of penetration of the roof and be at least 2 ft higher than any point on the roof wall or building within 10 ft of it 6 The raincap and storm collar should now be fastened to the top of the chimney Install additional support s as indicated by chim ney manufacturer s instructions result if stand offs are not properl...

Page 12: ... 5000 13 92 15 08 16 24 17 4 20 88 18 56 23 2 5000 6000 14 40 15 60 16 80 18 0 21 60 19 20 24 0 6000 7000 14 88 16 12 17 36 18 6 22 32 19 84 24 8 7000 8000 15 36 16 64 17 92 19 2 23 04 20 48 25 6 8000 9000 15 84 17 16 18 48 19 8 23 76 21 12 26 4 9000 10000 16 32 17 68 19 04 20 4 24 48 21 76 27 2 3 Chimney Maintenance It is important that you inspect your chimney regularly and keep it clean If you ...

Page 13: ...ng the flange on the fireplace side Duct must be secured by screws or clamp Outside Air Inlet must be 6 ft below the chimney termination point WIRING THE WARMHEARTH Field wire main power supply to fireplace for fan kit All electrical connections should only be performed by a licensed certified electrician INSTALLATION OPTION 1 Internal Blower with Thermo Disc The thermodisc provides the user with ...

Page 14: ... cover A on top of the unit 2 Take the connector collar and rotate it in the holetocutthrough4 ofinsulation Removethe insulation from pipe 3 Remove the screws on the lower cover Vent cover B and slide it back under the insulation 4 Slide the connector collar into the flex duct and secure with an adjustable clamp FANPARTNUMBERS The parts listed below are available from Re gency Please see your Rege...

Page 15: ... 4 x 7 3 4 opening is required to fit the frame that is supplied The vent must be installed in the chase and should be within 12 of the floor WARNING Lower air vent MUST be installed in all applications other wise serious overheating of the chase may result 9 Fasten the block off plate to the Warm Hearth using the existing holes that normal ly secure the louvers using the louver screws Make sure t...

Page 16: ...replace In a 2 story home one good location would be in the ceiling of the basement because you must be able to access it for oiling and replacement Note The blower can be installed al most anywhere in the home How ever some thought should be put into the planning to ensure blow er noise is kept away from rooms that want quiet Length of runs should be kept to a minimum to conserve space and minimi...

Page 17: ...aaaaaaa Framing Metal Edging Extend unit past studs so it is flush with sheeting Drill Tap screws INSTALLATION FINISHING THE WARMHEARTH Completing the Facing Facing materials must be thin veneer non self supporting facades or self supporting facades If you are installing a thin veneer facade the Regency Masonry Retainer Kit Part 000 920 is recommended All facades must be Non Combustible such as br...

Page 18: ...ind Top mesh C so that it covers the stand off and will prevent mortar from falling through the mesh 8 Put the door on the unit and check that the veneer on the door hinge side does not interfere with the door swing 9 Use washers and screw top mesh C to top of grill frame This is attached with the top edge of the grill frame on piece B 10 Now fasten mesh to wall sheathing and blend in 11 Use only ...

Page 19: ...ng handle onto the handle bar LATCH ADJUSTMENT The door latch may require adjustment as the door gasket material compresses after a few fires Removal of the spacer washer shown in the diagram below will allow the latch to be moved closer to the door frame causing a tighter seal Remove and replace the nuts washer and spacer as shown SECONDARY AIR TUBE INSTALLATION 1 Slideairtubeintotheholeontheleft...

Page 20: ...xists Burning the stove at a very high temperature the first few times may damage the paint Burn fires at a moderate level the first few days 8 For those units installed at higher eleva tions drafting problems may occur Consult an experienced dealer on methods of in creasing your draft Follow the Flue Height Chart Table 1 page 12 9 Some cracking and popping noises may be experienced during the hea...

Page 21: ...tion Top Heat Shield 48 000 532 Standoff Top Assembly 50 000 127 Standoff Side 51 820 100 Standoff Back 54 000 910 Hearth Extension Optional 000 914 Black Louver set 60 Black Louver Assy Top 61 Black Louver Assy Bottom 000 916 Gold Louver set 62 Gold Louver Assy Top 63 Gold Louver Assy Bottom 68 836 175 Insulation Top Standoff Assy 82 000 927 Thermodisc Kit with wires Optional 83 000 201 Terminal ...

Page 22: ...ssembly 16 846 570 Med Density Door Gasket Kit 17 846 918 Hinge Caps 2 set 19 948 101 Spring Handle Large 69 836 171 Baffle Insulation 70 Globe 71 Retainer Post 72 902 108 Brick Bottom 73 902 107 Brick Back Right 74 902 106 Brick Back Left 75 902 112 Brick Side Left 76 902 113 Brick Side Right 77 836 132 Insulation Bottom Brick 78 836 133 Insulation Side Brick 79 836 131 Insulation Back Brick 80 0...

Page 23: ... will not be liable for results or costs of workmanship from unauthorized service persons or dealers At all times FPI reserves the right to inspect product in the field which is claimed to be defective All claims must be submitted to FPI by authorized selling dealers It is essential that all submitted claims provide all of the necessary information including customer name purchase date serial type...

Page 24: ...____________________________ Printed in Canada Regency fireplace products are designed with reliability and simplicity in mind In addition our internal Quality Assur ance Team carefully inspects each unit thoroughly before it leaves our door Fireplace Products Internation al Ltd is pleased to extend this Limited Lifetime Warranty to the original purchaser of a Regency Product See the inside back c...

Reviews: