Regency
®
U39EX ULTIMATE™ Freestanding Gas Stove
|
27
installation
DV Stove Horizontal Vent Kit Installation
Review the following sequence of instructions which are typical of most installations. The sequence may vary depending on wall thickness.
Minimum I
nstal
lation Height:
U39E: 59-3/4" ( 1518mm)
DV Stove Horizontal Vent Kit (# 946-116 & #946-216)
DV Stove Horizontal Vent Kit 2 ft. (Part # 946-116) or 4 ft. (Part # 946-216) includes all the parts needed to install the U39EX with minimum horizontal and
vertical vent dimensions. For installations that require longer vertical and/or horizontal vents see the
"Dura-vent Termination Kit” and “Component" sections.
Qty. Description
1.
1 Rigid Pipe Section (Kit # 946-116: 2 ft. (1.2m) length,
Kit # 946-216: 4 ft. (1.2m) length), 6-1/2" (165mm) inside diameter
2.
1 Flex Liner, compressed aluminium 2 ply liner,
4" (102mm) inside diameter
3.
4 spring spacers
4.
1 90 deg. Elbow
5.
1 Adjustable pipe section 13-1/2" to 24" (343mm x 610mm), 2 pieces
6.
1 Thimble Cover
7.
1 Wall Thimble (2 pcs.)
8.
1 Adapter
9.
1
AstroCap
Termination Cap
10.
2 Trim Collar
11.
1 tube of Mill-Pac, high temperature sealant
12.
12 Screws, #8 x 1/2" Self tapping, Stainless Steel
13.
13 Screws, #8 x 1/2" Self tapping, Black
14.
4 Screws #8 x 1-1/2" Drill Point, Black
15.
4 Screws #8 x 1-1/2" Drill Point, Stainless Steel
16.
8 Wood screws #8 x 1"
Optional:
946-206 Vinyl Siding Standoff for
AstroCap
Note:
Refer to vent location and clearance
dimensions in "Exterior Vent Termination
Locations" to "DV Stove Horizontal Vent
Kit" sections.
1. Set the unit in its desired location. Check
to determine if wall studs will be in the way
of the venting system, adjust location until
all clearances are met and there are no
obstructions.
Note: A 1-1/2"(38mm) clearance
around the outer pipe must be
maintained except that only a 1"
(25mm) clearance is needed at
the termination end.
IMPORTANT:
Do not locate termination hood where
excessive snow or ice buildup may occur.
Be sure to check vent termination area after
snow falls, and clear to prevent accidental
blockage of venting system. When using
snow blowers, make sure snow is not directed
towards vent termination area.
2. Assemble a
trial fit
to determine the vertical
center-line for the vent termination.
a) Cut a 9-1/2" x 9-1/2" (241mm x 241 mm)
square hole on both the interior and
exterior wall.
b) Install wall thimbles on both interior and
exterior wall with 4 wood screws (#8 x
1") per thimble.
c) Attach the 2 piece adjustable pipe section
to the vent terminal and slide into position
from the exterior. The larger diameter end
of the adjustable pipe goes to the vent
terminal.
d) Install the 90
o
elbow onto the adjustable
pipe to determine the vertical centerline
of the starter collar on the unit.
Note: if the centerline cannot be met,
the adjustable sections will have to
be cut.
a) Liner sections should be continuous without any joints or
seams.
b) This is an approved system, therefore components in this
system must not be substituted for any other manufacturer's
products.