Regency Plateau PTO30-LPG1 Owners & Installation Manual Download Page 25

Regency Plateau™ PTO30 Outdoor Gas Fireplace

25

25

INSTALLATION

OPERATING INSTRUCTIONS

COPY OF LIGHTING PLATE INSTRUCTIONS

918-892a

Part #: 918-892a

Colours: Black on Grey,  except   

   

for parts indicated as being     

   

Red.

**Decal can not be any wider than cut 

line (dotted line) limited clearance.

Size:              100%

                         w- 2.4"

                         h- 16.9"

                

Jan 19/10: Created draft for approval

Feb 16/10: Changed size of decal 

        

FOR YOUR SAFETY READ BEFORE LIGHTING

A)   

This appliance is equipped with an ignition device which automatically lights the pilot. 

     Do not try to light the pilot by hand.

B)   BEFORE OPERATING

 smell all around the appliance area for gas. Be sure to smell next to 

     the fl oor because some gas is heavier than air and will settle on the fl oor.

WHAT TO DO IF YOU SMELL GAS

-  Do not try to light any appliance.

-  Do not touch any electric switch, do  not use any phone in your building.

-  Immediately call your gas supplier from a neighbours phone. Follow the gas supplier’s instructions.

-  If you cannot reach your gas supplier, call the fi re department.

A)  

Cet appareil est muni d’un dispositif d’allumage qui allume automatiquement la veilleuse. 

       Ne tentez pas d’allumer la veilleuse manuellement. 

B) AVANT DE FAIRE FONCTIONNER

, renifl ez tout autour de l’appareil pour déceler une odeur 

      de gaz.  Renifl ez près du plancher, car certains gaz sont pluslourds que l’air et peuvent        

      s’accumuler au niveau du sol.

 

QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ 

:

    • Ne pas tenter d’allumer d’appareil

    • Ne touchez à aucun interrupteur; ne pas vous servir des téléphones se trouvant dans le 

      bâtiment.

    • Appelez immédiatement votre fournisseur de gaz depuis un voisin. Suivez les  

      instructions du fournisseur.

    • Si vous ne pouvez rejoindre le fournisseur, appelez le service des incendies

DO NOT REMOVE 

THIS INSTRUCTION PLATE

This appliance must be installed in accordance with local codes, if any;

if none, follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or

Natural Gas and Propane Installation Codes, CSA B149.1.

 LIGHTING INSTRUCTIONS

STOP! Read the safety information on this label.

1) 

Turn off ON/OFF switch 

2) 

If service is to be performed - 

you must disconnect power to 

the unit, from the battery pack, 

refer to manual

1)

 

Appuyez sur le bouton ON / 

OFF 

2) 

 Si le service est effectuée, 

vous devez débrancher 

l'appareil, du bloc-piles, voir le 

manuel d'instruction pour plus 

de détails.

1)  Turn on ON/OFF switch 

2)   After approximately 4 seconds the spark ignition system will spark 

for 60 seconds to light the main burner.

3)  The unit will turn on.

Note: The fi rst attempt to ignition will last approximately 60 seconds. 

If there is no fl ame ignition (rectifi cation) the board will stop sparking 

for approximately 35 seconds. After this wait time, the board will start 

a second try for ignition by sparking for approximately 60 seconds. 

If there is still no positive ignition after the second attempt the board 

will go into lock out.

The system will need to be reset as follows (after going      

                  

into lock out mode):

 

a)   Wait 5 minutes - turn the system off using ON/OFF     

switch. 

b)   After approximately 2 seconds turn on ON/OFF switch.

c) Unit will repeat step 2.

CAUTION:  

H o t   w h i l e   i n 

operation.  Do  not 

t o u c h .   S e v e r e 

Burns  may  result. 

Due to high surface 

t e m p e r a t u r e s 

k e e p   c h i l d r e n , 

c l o t h i n g   a n d 

furniture,  gasoline 

and  other  liquids 

having  flammable 

vapors away. Keep 

burner  and  control 

compartment clean. 

See  installation 

a n d   o p e r a t i n g 

i n s t r u c t i o n s 

a c c o m p a n y i n g 

appliance.

WARNING: If you do not follow these instructions exactly, a fire or 

explosion  may  result  causing  property  damage,  personal  injury  or 

loss of life. Improper installation, adjustment, alteration, service or 

maintenance can cause injury or property damage. Refer to the owner’s 

information manual provided with this appliance. For assistance or 

additional  information  consult  a  qualified  installer, service  agency 

or gas supplier.

AVERTISSEMENT. Quiconque ne respecte pas à la lettre les instructions 

dans la présente notice risquede déclencher un incendie ou une explosion 

entraînant des dommages, des blessures ou la mort.

Une installation, d'ajustement, de modifi cation, de service ou 

d'entretien peut provoquer des blessures ou des dommages matéri-

els. Reportez-vous au manuel du propriétaire de l'information fournie 

avec cet appareil. Pour obtenir de l'aide ou des informations supplé-

mentaires consulter un installateur qualifi é, une agence de service ou 

fournisseur de gaz.

TO TURN OFF 

GAS APPLIANCE

1)  Appuyez le bouton ON / OFF 

2)   Attendre 4 secondes. Le système d’allumage produira 

des étincelles pendant 60 secondes afi n d’amorcer le 

brûleur principal.

3)  Les fl ammes s’allumeront.

Remarque : Au premier allumage, le système tente 

d’allumer les fl ammes pendant 60 secondes. Si l’essai est 

infructueux, le système fait une pause de 35 secondes. 

C’est ce qu'on appelle l'étape de rectifi cation. Ce délai 

écoulé, le système tente à nouveau d'allumer les fl ammes 

en produisant des étincelles pendant 60 secondes. Si les 

fl ammes ne s’allument toujours pas, le système se met 

en mode verrouillage.

 

 Il faut alors le réinitialiser en suivant les 

étapes ci-dessous (pour le déverrouiller) :

                 a)   Attendre 5 minutes et éteindre l’appareil en 

réglant l’interrupteur à la position « OFF »; 

                 b)   Attendre 2 secondes et rallumer le système 

à l’aide de l’interrupteur. 

                  c)  L'unité répétera l'étape 2.

918-892a

Part #: 918-892a

Colours: Black on Grey,  except   

   

for parts indicated as being     

   

Red.

**Decal can not be any wider than cut 

line (dotted line) limited clearance.

Size:              100%

                         w- 2.4"

                         h- 16.9"

                

Jan 19/10: Created draft for approval

Feb 16/10: Changed size of decal 

        

FOR YOUR SAFETY READ BEFORE LIGHTING

A)   

This appliance is equipped with an ignition device which automatically lights the pilot. 

     Do not try to light the pilot by hand.

B)   BEFORE OPERATING

 smell all around the appliance area for gas. Be sure to smell next to 

     the fl oor because some gas is heavier than air and will settle on the fl oor.

WHAT TO DO IF YOU SMELL GAS

-  Do not try to light any appliance.

-  Do not touch any electric switch, do  not use any phone in your building.

-  Immediately call your gas supplier from a neighbours phone. Follow the gas supplier’s instructions.

-  If you cannot reach your gas supplier, call the fi re department.

A)  

Cet appareil est muni d’un dispositif d’allumage qui allume automatiquement la veilleuse. 

       Ne tentez pas d’allumer la veilleuse manuellement. 

B) AVANT DE FAIRE FONCTIONNER

, renifl ez tout autour de l’appareil pour déceler une odeur 

      de gaz.  Renifl ez près du plancher, car certains gaz sont pluslourds que l’air et peuvent        

      s’accumuler au niveau du sol.

 

QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ 

:

    • Ne pas tenter d’allumer d’appareil

    • Ne touchez à aucun interrupteur; ne pas vous servir des téléphones se trouvant dans le 

      bâtiment.

    • Appelez immédiatement votre fournisseur de gaz depuis un voisin. Suivez les  

      instructions du fournisseur.

    • Si vous ne pouvez rejoindre le fournisseur, appelez le service des incendies

DO NOT REMOVE 

THIS INSTRUCTION PLATE

This appliance must be installed in accordance with local codes, if any;

if none, follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or

Natural Gas and Propane Installation Codes, CSA B149.1.

 LIGHTING INSTRUCTIONS

STOP! Read the safety information on this label.

1) 

Turn off ON/OFF switch 

2) 

If service is to be performed - 

you must disconnect power to 

the unit, from the battery pack, 

refer to manual

1)

 

Appuyez sur le bouton ON / 

OFF 

2) 

 Si le service est effectuée, 

vous devez débrancher 

l'appareil, du bloc-piles, voir le 

manuel d'instruction pour plus 

de détails.

1)  Turn on ON/OFF switch 

2)   After approximately 4 seconds the spark ignition system will spark 

for 60 seconds to light the main burner.

3)  The unit will turn on.

Note: The fi rst attempt to ignition will last approximately 60 seconds. 

If there is no fl ame ignition (rectifi cation) the board will stop sparking 

for approximately 35 seconds. After this wait time, the board will start 

a second try for ignition by sparking for approximately 60 seconds. 

If there is still no positive ignition after the second attempt the board 

will go into lock out.

The system will need to be reset as follows (after going      

                  

into lock out mode):

 

a)   Wait 5 minutes - turn the system off using ON/OFF     

switch. 

b)   After approximately 2 seconds turn on ON/OFF switch.

c) Unit will repeat step 2.

CAUTION:  

H o t   w h i l e   i n 

operation.  Do  not 

t o u c h .   S e v e r e 

Burns  may  result. 

Due to high surface 

t e m p e r a t u r e s 

k e e p   c h i l d r e n , 

c l o t h i n g   a n d 

furniture,  gasoline 

and  other  liquids 

having  flammable 

vapors away. Keep 

burner  and  control 

compartment clean. 

See  installation 

a n d   o p e r a t i n g 

i n s t r u c t i o n s 

a c c o m p a n y i n g 

appliance.

WARNING: If you do not follow these instructions exactly, a fire or 

explosion may result causing property damage, personal injury or 

loss of life. Improper installation, adjustment, alteration, service or 

maintenance can cause injury or property damage. Refer to the owner’s 

information manual provided with this appliance. For assistance or 

additional information consult a qualified installer, service agency 

or gas supplier.

AVERTISSEMENT. Quiconque ne respecte pas à la lettre les instructions 

dans la présente notice risquede déclencher un incendie ou une explosion 

entraînant des dommages, des blessures ou la mort.

Une installation, d'ajustement, de modifi cation, de service ou 

d'entretien peut provoquer des blessures ou des dommages matéri-

els. Reportez-vous au manuel du propriétaire de l'information fournie 

avec cet appareil. Pour obtenir de l'aide ou des informations supplé-

mentaires consulter un installateur qualifi é, une agence de service ou 

fournisseur de gaz.

TO TURN OFF 

GAS APPLIANCE

1)  Appuyez le bouton ON / OFF 

2)   Attendre 4 secondes. Le système d’allumage produira 

des étincelles pendant 60 secondes afi n d’amorcer le 

brûleur principal.

3)  Les fl ammes s’allumeront.

Remarque : Au premier allumage, le système tente 

d’allumer les fl ammes pendant 60 secondes. Si l’essai est 

infructueux, le système fait une pause de 35 secondes. 

C’est ce qu'on appelle l'étape de rectifi cation. Ce délai 

écoulé, le système tente à nouveau d'allumer les fl ammes 

en produisant des étincelles pendant 60 secondes. Si les 

fl ammes ne s’allument toujours pas, le système se met 

en mode verrouillage.

 

 Il faut alors le réinitialiser en suivant les 

étapes ci-dessous (pour le déverrouiller) :

                 a)   Attendre 5 minutes et éteindre l’appareil en 

réglant l’interrupteur à la position « OFF »; 

                 b)   Attendre 2 secondes et rallumer le système 

à l’aide de l’interrupteur. 

                  c)  L'unité répétera l'étape 2.

The lighting plate is located on the underside of the table top on the unit.

Summary of Contents for Plateau PTO30-LPG1

Page 1: ...ch do not use any phone in your building Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department WARNING Improper installation adjustment alteration service or maintenance cancauseinjuryorpropertydamage Read the installation operating and maintenanceinstructionsthoroughly before installing or ...

Page 2: ...TO30 Outdoor decorative gas appliance has been designed to provide you with all the charm of a fire at the flick of a switch The Plateau PTO30 Outdoor Decorative Gas Appliance has been approved by IAPMO for both safety and efficiency As it also bears our own mark it promises to provide you with economy comfort and security for many trouble free years to follow Please take a moment now to acquaint ...

Page 3: ...High Elevation 13 Gas Line Installation 13 Pilot Adjustment 13 Gas Pipe Pressure Testing 13 886 S I T Valve 13 Description 13 Aeration Adjustment 13 PTO30 wall switch installation 14 PTO30 Drain Installation Recommended 15 PTO30 Wiring Diagram 16 Table Cover Installation 17 Glass Crystal Basalt volcanic stones installation 18 Glass surround Installation 19 Operating Instructions 24 Lighting Proced...

Page 4: ...have printed a copy of the contents here for your review NOTE Regency units are constantly being improved Check the label on the unit and if there is a difference the label on the unit is the correct one Primarily a decorative appliance not certified as a space heater TO BE INSTALLED BY AN AUTHORISED PERSON THIS APPLIANCE SHALL NOT BE INSTALLED OR USED INDOORS ...

Page 5: ...PTO30 FINISHED TABLE TOP AND UNIT DIMENSIONS 8 1 4 210mm HOLES 9 1 8 231mm 10 9 16 627mm MOUNTING 1 3 16 30mm OUTSIDE OF UNIT TO MOUNTING HOLES 36 7 16 932mm 33 1 4 844mm 10 3 8 263mm 37 9 16 953mm 2 3 8 60mm TOP VIEW SIDE VIEW END VIEW 1 2 13mm to ADJUSTABLE ...

Page 6: ...Y CALL A QUALIFIED SERVICE TECHNICIAN TO INSPECT THE APPLIANCE AND TO REPLACE ANY PART OFTHE CONTROL SYSTEM AND ANY GAS CONTROL WHICH HAS BEEN UNDER WATER YOUNG CHILDREN SHOULD BE CARE FULLY SUPERVISED WHENTHEY ARE IN THE SAME AREA AS THE APPLI ANCE TODDLERS YOUNG CHILDREN AND OTHERS MAY BE SUSCEPTIBLE TO ACCIDENTAL CONTACT BURNS A PHYSICALBARRIERSISRECOMMEND ED IFTHERE ARE AT RISK INDIVIDUAL INTH...

Page 7: ...ended 3 Install ON OFF switch ensure it is in the OFF position 4 Make gas connections test for leaks 5 Install 4 AA batteries into each battery pack This unit will not operate without AA batteries in place 6 Install standard and optional features Refer to the following sections a Tabletop Installation b Glass Crystals c Volcanic Stone Installation optional d Glass Surround Installation e Weather C...

Page 8: ...e greatest importance that this decorative gas appliance be installed only in accordance with these instructions PTO30 Clearance Requirements E F Alcove PTO30 BURNER MUST BE INSTALLED AT A MINI MUM OF 750MM ABOVE GROUND IF INSTALLED LOWER IT IS REQUIRED TO INSTALL THE OP TIMAL DECORATIVE GLASS SURROUND AND ENSURE MINIMUM HEIGHT IS 750MM TO TOP OF GLASS SURROUND IFINSTALLEDLOWERTHAN750MMWITHGLASS S...

Page 9: ...be non combustible when used within 4 of the unit Combustible framing materials may be used outside the 4 clearance range Finishing materials MUST be non combustible Consideration should be given to weather elements when choosing framing materials ie treated lumber steel stud PTO30 NOTE PTO30 Two 2 ventilation grills are required for all enclosures This is to alleviate moisture and allow for air t...

Page 10: ...y remove pilot orifice and replace with LPG ULPG pilot orifice 5 Remove burner orifice with a 1 2 wrench Use another wrench to hold on to the elbow behind the orifice Discard orifice Repeat steps to install LPG ULPG orifice 7 Re install pilot cap 8 Adjust aeration accordingly see manual for details 1 Remove table top if installed by lifting up and off use caution if glass surround is in place 2 Re...

Page 11: ...tions 10 Remove Hi Lo pressure regulator by removing 2 screws as shown below Reverse steps to install LP pressure regulator Be sure diaphragm and spring are removed HI LO pressure regulator 13 Check all gas connections under normal operating pressure for leaks with soapy water NOTE If soap bubbles this would indicate a gas leak 14 Check inlet and outlet pressures 15 Check operation of flame contro...

Page 12: ...n 1 4 or 1 8 increments Each hole on the inside line is 1 8 each hole on the outside line is 1 4 Determine the thickness of the finishing material before adjusting the nailing strips OPTIONAL FINISHING TRIM 1 2 1 4 Increments 1 8 Increments 2 3 8 Nailing strip FINISHING MATERIALS This burner is designed to be finished with non combustible materials ie tile granite marble brick etc with a minimum t...

Page 13: ...des it is always best to consult with your local authorities and the CAN CGA B149 installation code For USA installations follow local codes and or the current National Fuel Gas Code ANSI Z223 1 When using copper or flex connectors use only approved fittings Always provide a union so that gas lines can be easily disconnected for servicing Flare nuts for copper lines and flex connectors are usually...

Page 14: ...ef nut not required 4 Route low voltage wire and battery extension wire through the strain relief 5 Connect low voltage wire to supplied switch fasten switch to right side of electrical box polarity not important 8 Place supplied gasket on top of electrical box 9 Fasten cover to electrical box using supplied screws 10 Place switch in OFF position until final installation is complete Center knock o...

Page 15: ...aded coupling reducer going from the top of the pan down through the hole Apply a silicone based sealant around the base and threads before installation Cut notches into the top of the coupling reducer to prevent water pooling 3 Holding the reducer coupling with a wrench thread a 90 PVC elbow from the underside of the unit to the reducer until it is tight to the metal 4 Reinstall bracket from Step...

Page 16: ...st be installed in the battery pack to operate the burner switch Do not use a 9 volt battery The appliance when installed must be electrically grounded in accordance with local codes or in the absence of local codes with the National Electrical Code ANSI NFPA 70 if applicable 0 886 001 Proflame Valve Standard Main On Off Switch or Optional Wall Switch Proflame System ...

Page 17: ...door Gas Fireplace 17 INSTALLATION TABLE COVER INSTALLATION 919 056 08 15 11 2 End Cap Final Install TABLE COVER INSTALLATIONS DINING LEAF For all units 1 Place the dining leaf cover over the burner of the unit when not in use ...

Page 18: ...laces Use of any other type of glass crystals or stones can alter the unit s performance any damage caused by the use of any unapproved glass or stones will not be covered under warranty When using Basalt Volcanic Stones DO NOT cover pilot light that lead to pilot flame 1 Start pouring Crystals on one end of the burner 2 Work Crystals to other end of the Burner Base and burner tube should not be v...

Page 19: ...be placed and secured 4a After the 4 top brackets are installed flip over and place on a soft surface to install the 4 bottom brackets 7 Place assembled glass surround windshield on table top ensure glass is centered on the table top Once in correct position lift up one end apply double sided tape that has been cut to size to the bottom of the brackets Repeat process on other end Press down firmly...

Page 20: ...2 Vertical Supports Tall B x 8 Vertical Supports Short C x 6 Base D x 1 Short Brace E x 4 Header F x 2 Vents 4 Wafer Screws 80 Tools Required 1 power drill 2 phillips bit 1 hand 2 screwdriver Phillips 1 level 1 tape measure PTO30 BURNER MUST BE INSTALLED AT A MINIMUM OF 750MM ABOVE GROUND IF INSTALLED LOWER IT IS REQUIRED TO INSTALL THE DECORATIVE GLASS SURROUND AND ENSURE MINIMUM HEIGHT IS 750MM ...

Page 21: ...y and inner tall vertical supports Part B on lower frame Part A 3 Attach inside tall vertical supports Part B to short vertical supports Part C with one 1 screw each 4 Secure all vertical supports Part B with two 2 screws each to lower frame Part A 5 Place top frame Part A on inside tall vertical supports Part B 6 Secure in place with two 2 screws for each support 7 Manoeuvre in outside tall verti...

Page 22: ...crews for each support 10 Install two 2 headers Part F with four 4 screws each to complete frame installation If installing optional panels continue on to next section Diagram 10 Diagram 12 Part F locations Diagram 13 14 Part F Diagram 11 Screw Locations OPTIONAL PANELS 1 Bend tabs on top flange of side panel to 90º Diagram 1 Bend tabs to 90º 2 Position panel lower tabs line up with indents in bas...

Page 23: ...iagram 2 Top Panel screw locations Diagram 3 Bend tabs flat panels is supported on headers 3 Bend tabs flat the side panel will then be supported to allow the installation of the top panel 4 Install top panel with six 6 screws in locations shown below Flattened Tabs Header Opacity reduced ...

Page 24: ...e if required 4 Check all connections with soap and water clean after as some detergents are corrosive 5 Check all connection fitting hoses prior to each use OPERATING INSTRUCTIONS 1 Readandunderstandtheseinstructionsbefore operating this appliance 2 Check to see that all wiring is correct and enclosed to prevent possible shock 3 Check to ensure there are no gas leaks 4 Check all hoses and connect...

Page 25: ...înant des dommages des blessures ou la mort Une installation d ajustement de modification de service ou d entretien peut provoquer des blessures ou des dommages matéri els Reportez vous au manuel du propriétaire de l information fournie avec cet appareil Pour obtenir de l aide ou des informations supplé mentaires consulter un installateur qualifié une agence de service ou fournisseur de gaz 918 89...

Page 26: ...of the panels Use an ammonia based cleaner ie glass cleaner to remove this film before applying heat to the unit Failure to do this will result in burn stains on panels which you will be unable to remove 5 The heater is finished in a heat resistant paint and should only be refinished with heat resistant paint Regency uses StoveBright Paint Metallic Black 6309 6 Make a periodic check of burner for ...

Page 27: ...he gas valve 8 Remove green EV2 wire connected to the gas valve 9 Remove 10 screws securing valve assembly 10 Lift valve assembly up and out 11 Remove both yellow green ground wires from valve and valve bracket 12 Replace valve assembly gasket if necessary 13 Rotate HI LO modulationg valve all the way to the left for HI position 14 Install new valve assembly and reverse steps 11 1 15 Test gas conn...

Page 28: ...6 Mounting Bracket 4 377 034 Pilot Shield 5 377 027 Burner Mount 6 377 028 Burner Tray End 7 377 030 Offset Bracket 8 376 512 Electronic Assembly Part Description 9 376 526 Burner 10 377 045 Firebox 11 377 046 Controls Enclosure 12 377 510 Valve Tray 13 377 047 Components Cover 14 377 048 Pilot Shield support 15 377 054 Drainage Bracket ...

Page 29: ...Regency Plateau PTO30 Outdoor Gas Fireplace 29 NOTES ...

Page 30: ...All installations must be performed by a qualified gas fitter and installed according to all applicable local and national codes Also all service work must be carried out by a qualified gas service person provided by the selling dealer It is the responsibility of the installer to ensure that the appliance is firing as per rating plate Any part or parts of this unit which in our judgement show evid...

Page 31: ...oducts Australia PTY Ltd 28 30 Division St 1 3 Conquest Way Welshpool WA 6106 Hallam VIC 3803 08 9350 2200 03 9799 7277 NOTE PLEASE RETAIN YOUR INVOICE AS PROOF OF PURCHASE FOR WARRANTY VERIFICATION INCORRECT INSTALLATION OR GAS PRESSURE SETTINGS ARE NOT COVERED BY WARRANTY A SERVICE OR CALLOUT FEE WILL BE CHARGED IN THESE CIRCUMSTANCES ...

Page 32: ...________________________________ Date Installed _______________________________________________________ Serial No ___________________________________________________________ Register your Regency warranty online www regency fire com au Reasons to register your product online today View and modify a list of all your registered products Request automatic email notification of new product updates Sta...

Reviews: