Regency Plateau PTO30-LP Owners & Installation Manual Download Page 7

Regency Plateau™ PTO30 Outdoor Gas Fireplace

7

INSTALLATION

IMPORTANT MESSAGE  

SAVE THESE 

INSTRUCTIONS

The PTO30 Outdoor Decorative Gas Appliance must 
be installed in accordance with these instructions. 
Carefully read all the instructions in this manual 
fi rst. Consult the "authority having jurisdiction" to 
determine the need for a permit prior to starting the 
installation. It is the responsibility of the installer to 
ensure this decorative gas appliance is installed in 
compliance with manufacturers instructions and all 
applicable codes.

BEFORE YOU START

Safe installation and operation of this appliance 
requires common sense, however, we are required 
by the Canadian Safety Standards and ANSI 
Standards to make you aware of the following:

GENERAL SAFETY 

INFORMATION

1) 

The installation must conform with local 
codes or, in the absence of local codes, with 

CAN/CSA-B149.1

, Natural Gas and Propane 

Installation Code or 

CAN/CSA-B149.2

, Propane 

installation code the Natural Gas Fuel Code, 

ANSI Z223.1/NFPA 54

.

 

2)

  See general construction and assembly 

instructions. The appliance should be enclosed.

3)

  Inspect the burner before each use of the 

appliance for blockage and any signs of 
deterioration

CHILDREN AND ADULTS SHOULD BE 
ALERTED TO THE HAZARDS OF HIGH 
SURFACE TEMPERATURES,  ESPE-
CIALLY THE DECORATIVE GAS APPLI-
ANCE GLASS AND FACEPLATE, AND 
SHOULD STAY AWAY TO AVOID BURNS 
OR CLOTHING IGNITION.  

THIS APPLIANCE SHALL BE USED 
ONLY OUTDOORS IN A WELL-VENTI-
LATED SPACE AND SHALL NOT BE 
USED IN A BUILDING, GARAGE OR ANY 
OTHER ENCLOSED AREA.

INSTALLATION AND REPAIR SHOULD 
B E   D O N E   B Y   A N   AU T H O R I Z E D 
SERVICE PERSON. THE APPLIANCE 
SHOULD BE INSPECTED BEFORE 
USE AND AT LEAST ANNUALLY BY A 
PROFESSIONAL SERVICE PERSON. 
MORE FREQUENT CLEANING MAY 
BE REQUIRED DUE TO EXCESSIVE 
LINT FROM CARPETING, BEDDING 
MATERIAL, ETC. IT IS IMPERATIVE THAT 
CONTROL COMPARTMENTS, BURNERS 
AND CIRCULATING AIR PASSAGEWAYS 
OF THE APPLIANCE BE KEPT CLEAN.

ANY GUARD OR OTHER PROTECTIVE 
DEVICE REMOVED FOR SERVICING 
THE APPLIANCE MUST BE REPLACED 
PRIOR TO OPERATING THE APPLIANCE

WARNING: FAILURE TO INSTALL THIS 
APPLIANCE CORRECTLY WILL VOID 
YOUR WARRANTY AND MAY CAUSE A 
SERIOUS FIRE.

CLOTHING OR OTHER FLAMMABLE 
MATERIAL SHOULD NOT BE PLACED 
ON OR NEAR THE APPLIANCE.

   

DO NOT SIT OR STAND ON DECORATIVE 
GAS APPLIANCE.

SOLID FUELS SHALL NOT BE BURNED 
IN THIS  APPLIANCE.

DO NOT USE THIS APPLIANCE IF 
ANY PART HAS BEEN UNDER WATER. 
IMMEDIATELY CALL A QUALIFIED 
SERVICE TECHNICIAN TO  INSPECT 
THE APPLIANCE AND TO REPLACE 
ANY PART OF THE CONTROL SYSTEM 
AND ANY GAS CONTROL WHICH HAS 
BEEN UNDER WATER.

YOUNG CHILDREN SHOULD BE CARE-
FULLY  SUPERVISED WHEN THEY ARE 
IN THE SAME AREA AS THE APPLI-
ANCE.  TODDLERS, YOUNG CHILDREN 
AND OTHERS MAY BE SUSCEPTIBLE 
TO ACCIDENTAL CONTACT BURNS.  A 
PHYSICAL BARRIERS IS RECOMMEND-
ED IF THERE ARE AT RISK INDIVIDUAL 
IN THE HOUSE.  TO RESTRICT ACCESS 
TO A DECORATIVE GAS APPLIANCE 
OR STOVE, INSTALL AN ADJUSTABLE 
SAFETY GATE TO KEEP TODDLERS, 
YOUNG CHILDREN AND OTHER AT RISK 
INDIVIDUALS OUT OF THE ROOM AND 
AWAY FROM HOT SURFACES. 

4)

  To prevent injury, do not allow anyone who 

is unfamiliar with the operation to use the 
decorative gas appliance.

5)

  Wear gloves and safety glasses for protection 

while doing required maintenance.

6)

  Maximum gas inlet pressure = 1/2 psig.

7)

  Under no circumstances should this appliance 

be modifi ed. Parts that have to be removed for 
servicing should be replaced prior to operating 
this appliance.

8)

  Installation and any repairs to this appliance 

should be done by a qualifi ed service person. 
A professional service person should be called 
to inspect this appliance annually. Make it a 
practice to have all of your gas appliances 
checked annually.

9)

  Under no circumstances should any solid fuels 

(wood, paper, cardboard, coal, etc.) be burned 
in this appliance.

10)

 The appliance and its individual shutoff valve 

must be disconnected from the gas supply 
piping system during any pressure testing of 
that system at test pressures in excess of 1/2 
psi (3.5kPa).

 

The appliance must be isolated from the gas 
supply piping system by closing its individual 
manual shutoff valve during any pressure testing 
of the gas supply piping system at test pressures 
equal to or less than 1/2 psi (3.5 kPa).

11)

 The appliance area must be kept clear and 

free of combustible materials, (gases and other 
fl ammable vapours and liquids).

      

It is highly recommended to protect the 
interior from moisture (rain, snow).  Cover 
the enclosure opening when not in use.  This 
decorative gas appliance is only for use 
with the type of gas indicated on the rating 
plate.  This decorative gas appliance is not 
convertible for use with other gases, unless a 
certifi ed kit is used.

12)

  Stainless Steel/ Sunset Bronze Weather 

Cover

 must 

be removed when burner is in 

operation.

13)

 When not using appliance for extended periods 

of time - turn off gas supply and install Stainless 
Steel Weather Cover.

Emissions from burning  wood or gas could 
contain chemicals known to the State of 
California to  cause cancer, birth defects or 
other reproductive harm.

Summary of Contents for Plateau PTO30-LP

Page 1: ... appliance Extinguish any open flame If odour continues keep away from the appliance and im mediately call your gas supplier or fire department Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department WARNING Improper inst...

Page 2: ...as Appliance by REGENCY The Plateau PTO30 Outdoor decorative gas appliance has been designed to provide you with all the warmth and charm of a fire at the flick of a switch The Plateau PTO30 Outdoor Decorative Gas Appliance has been approved by Warnock Hersey Intertek for both safety and efficiency As it also bears our own mark it promises to provide you with economy comfort and security for many ...

Page 3: ...Pipe Pressure Testing 11 886 S I T Valve Description 11 Aeration Adjustment 11 PTO30 wall switch installation 12 PTO60 wall switch installation 13 Drain Installation Recommended 14 Wiring Diagram 15 PTO60 assembly 16 PTO30 table top Installation 17 PTO60 table top Installation 18 Glass crystal installation on burner 19 Volcanic stone installation on burner 20 Optional Log Set Installation 21 Optio...

Page 4: ...tu h 14 65 kW 30 000 Btu h 8 79 kW 3 5 0 87kPa 25 DMS 0 4500 ft pi 0 1372 m Pression d allimentation minimum Pression à la tubulure d chappement lev e Grandeur de l injecteur D bit maximum selon l altitude Pression d allimentation maximum Pression à la tubulure d chappement Calorifique D bit Calorifique minimum selon é é é é é basse é 14 WC C E 3 49 kPa 11 WC C E 2 74 kPa WC C E 6 4 WC C E 1 59 kP...

Page 5: ...0 FINISHED TABLE TOP AND UNIT DIMENSIONS 20 1 4 514mm 10 3 16 258mm 33 7 16 848mm 12 305mm 14 3 16 359mm 17 432mm 41 1 2 1054mm 37 15 16 963mm 18 9 16 470mm 12 13 16 352mm 6 152mm CL CL CL CL 17 432mm TOP VIEW SIDE VIEW END VIEW Shown with optional glass surround ...

Page 6: ...place DIMENSIONS PTO60 FINISHED TABLE TOP AND UNIT DIMENSIONS 71 13 16 1821mm 68 3 16 1731mm 68 5 16 1734mm 15 381mm 71 13 16 1821mm 15 432mm 12 13 16 325mm Shown with optional glass surround NOTE PTO60 is two PTO30 units assembled end to end ...

Page 7: ...Y CALL A QUALIFIED SERVICE TECHNICIAN TO INSPECT THE APPLIANCE AND TO REPLACE ANY PART OFTHE CONTROL SYSTEM AND ANY GAS CONTROL WHICH HAS BEEN UNDER WATER YOUNG CHILDREN SHOULD BE CARE FULLY SUPERVISED WHENTHEY ARE IN THE SAME AREA AS THE APPLI ANCE TODDLERS YOUNG CHILDREN AND OTHERS MAY BE SUSCEPTIBLE TO ACCIDENTAL CONTACT BURNS A PHYSICALBARRIERSISRECOMMEND ED IFTHERE ARE AT RISK INDIVIDUAL INTH...

Page 8: ... area is open and unrestricted INSTALLATION CHECKLIST 1 Locate appliance a Refer to LocatingYour Outdoor decorative gas appliance section b Clearances to Combustibles Refer to Clearances section c Framing Finishing Requirements Refer to Framing Finishing section 2 Drain Installation recommended 3 Install ON OFF switch ensure it is in the OFF position 4 Make gas connections test for leaks 5 Install...

Page 9: ...rances listed below are Minimum distances unless otherwise stated A major cause of fires is failure to maintain required clearances air space to combustible materials It is of the greatest importance that this decorative gas appliance be installed only in accordance with these instructions PTO30 Clearance Requirements Clearance Dimension Measured From A Back wall 17 432mm Burner to back wall B Sid...

Page 10: ... 1 2 978mm 15 381mm 10 1 2 267mm TOP VIEW SIDE VIEW END VIEW NOTE Framing materials may be combustible or non combustible Finishing materials MUST be non combustible Consideration should be given to weather elements when choosing framing materials ie treated lumber steel stud 68 1 2 1740mm 68 1 2 1740mm 10 1 2 267mm 15 381mm 15 381mm TOP VIEW SIDE VIEW END VIEW PTO30 PTO60 ...

Page 11: ...ckness of top facing and adjust nailing brackets Top facing material is to be brought to unit edge for finished look If using a material thicker than 1 on the top facing the table top opening must be maintained at 17 1 4 x 41 3 4 to allow for the proper fit Nailing brackets Nailing bracket Top 1 2 thick material Middle 3 4 thick material Bottom 1 thick material 17 1 4 41 3 4 Table Top Burner Openi...

Page 12: ... and the CAN CGA B149 installation code For USA installations follow local codes and or the current National Fuel Gas Code ANSI Z223 1 When using copper or flex connectors use only approved fittings Always provide a union so that gas lines can be easily disconnected for servicing Flare nuts for copper lines and flex connectors are usually considered to meet this requirement NOTE A shutoff dante va...

Page 13: ...wire and battery extension wire through the strain relief 5 Connect low voltage wire to supplied switch fasten switch to right side of electrical box polarity not important 8 Place supplied gasket on top of electrical box 9 Fasten cover to electrical box using supplied screws 10 Place switch in OFF position until final installation is complete Center knock out Strain Relief 6 Install supplied 4 AA...

Page 14: ...re the battery extension wires are approx 8 in length inside the electrical box This excess will ensure ease of battery replacement and servicing in the future 8 Using silicone completely seal strain relief to protect from water or moisture 9 Place supplied gasket on top of electrical box 10 Fasten cover to electrical box using supplied screws 11 Place switch in OFF position until final installati...

Page 15: ...exposed drain hole see location below install a PVC 3 4 threaded coupling reducer going from the top of the pan down through the hole Apply a silicone based sealant around the base and threads before installation Cut notches into the top of the coupling reducer to prevent water pooling 3 Holding the reducer coupling with a wrench thread a 90 PVC elbow from the underside of the unit to the reducer ...

Page 16: ...alled in the battery pack to operate the burner switch Do not use a 9 volt battery The appliance when installed must be electrically grounded in accordance with local codes or in the absence of local codes with the National Electrical Code ANSI NFPA 70 if applicable 0 886 001 Proflame Valve Standard Main On Off Switch or Optional Wall Switch ON OFF Switch PTO60 WIRING DIAGRAM ...

Page 17: ...lat Do this on each burner only on end shown below Note Removing a burner from one of the units will make it easier to stack the burners This step is recommended but not required 4 Reinstall burner 5 Line the two units up end to end Stack the flattened burner flanges from previous step one over top of the other Create a flat surface across both burners 6 Install units together into framing Secure ...

Page 18: ... operation This is normal and should not be considered a defect All hand and finger marks MUST be cleaned off with a soft cloth and a stainless steel cleaner Most stainless steel cleaners leave a film residue on the surface of the panels Use an ammonia based cleaner ie glass cleaner to remove this film before applying heat to the unit Failure to do this will result in burn stains on table top whic...

Page 19: ...This is normal and should not be considered a defect All hand and finger marks MUST be cleaned off with a soft cloth and a stainless steel cleaner Most stainless steel cleaners leave a film residue on the surface of the panels Use an ammonia based cleaner ie glass cleaner to remove this film before applying heat to the unit Failure to do this will result in burn stains on table top which you will ...

Page 20: ...nits come standard with Cobalt Blue glass crystals except HZO42 comes with Copper glass crystals HZI390E HZI390EB PTO30 PTO60 Plateau Series do NOT include glass crystals with units Must purchase separately 1 Ceramic Spa stone package contains 70 stones 1 Ceramic Garden stone package contains 50 stones Recommended use only 40 of the 70 ceramic stones on the HZ30E burner Recommended use only 24 of ...

Page 21: ...es Glass Crystals For the PTO30 PTO60 Plateau Series only Volcanic Stones Ivory Tan Glass Crystals For the HZO42 HZO42AUS only Volcanic Stones Slate Grey Glass Crystals For the HZO42 HZO42AUS only Evenly spread the glass crystals and volcanic stones over the burner Ensure the stones do not overlap too much as this will effect the flame pattern IMPORTANT NOTE Only the supplied approved Volcanic Sto...

Page 22: ...930 contains the following pieces Description Log A Log B Log C Log D Log E Log F Diagram 3 Diagram 2 Diagram 1 F E D C B A A D 2 Install log D on the burner as shown below Orient the log in the same way and in a similar location on the right side of the burner as shown in Diagram 3 1 Install log A as shown below Orient the log in the same way and in a similar location on the right side of the bur...

Page 23: ...lar position as shown in Diagram 6 6 Install log C on the left side of the burner as shown below Orient log C in the same way and in a similar position as shown in Diagram 7 Diagram 6 Diagram 7 Final Install F C 4 Install log B on the left side of the burner as shown below Orient log B in the same way and in a similar position as shown in Diagram 5 Diagram 5 B ...

Page 24: ...ed up 3 4 in bracket as shown below 4 Use supplied spacer tool to determine where the bottom bracket should be place and secured 3 After the 4 top bracket are installed flip over and place on a soft surface Install the 4 bottom brackets 6 Place assembled glass surround on table top ensure glass is centered on the table top Once in correct position lift up one end apply double sided tape that has be...

Page 25: ...ot be seen when lighting the unit the logs have been incorrectly positioned 5 The unit should never be turned off and on again without a minimum of a 60 second wait LIGHTING PROCEDURE 1 Turn on ON OFF switch 2 After approximately 4 seconds the spark igni tion system will spark for 60 seconds to light the main burner 3 The unit will turn on Note Thefirsttryforignitionwilllastapproximately 60 second...

Page 26: ...our obtenir de l aide ou des informations supplé mentaires consulter un installateur qualifié une agence de service ou fournisseur de gaz 918 892a s DO NOT REMOVE THIS INSTRUCTION PLATE LIGHTING INSTRUCTIONS STOP Read the safety information on this label 1 Turn off ON OFF switch 2 If service is to be performed you must disconnect power to the unit from the battery pack refer to manual 1 Appuyez su...

Page 27: ...of the panels Use an ammonia based cleaner ie glass cleaner to remove this film before applying heat to the unit Failure to do this will result in burn stains on panels which you will be unable to remove 5 The heater is finished in a heat resistant paint and should only be refinished with heat resistant paint Regency uses StoveBright Paint Metallic Black 6309 6 Make a periodic check of burner for ...

Page 28: ...he gas valve 8 Remove green EV2 wire connected to the gas valve 9 Remove 10 screws securing valve assembly 10 Lift valve assembly up and out 11 Remove both yellow green ground wires from valve and valve bracket 12 Replace valve assembly gasket if necessary 13 Rotate HI LO modulationg valve all the way to the left for HI position 14 Install new valve assembly and reverse steps 11 1 15 Test gas conn...

Page 29: ...t Assembly LP 5 904 951 Burner Orifice 25 NG 904 655 Burner Orifice 45 LP 376 028 Stainless steel weather cover Part Description 910 363 Wall switch not shown 6 376 932 Glass Surround 940 374 P Tempered Glass large 940 375 P Tempered Glass small 376 027 Glass connectors each 911 012 Ignition Board not shown 326 930 Log Set not shown 946 775 Fire glass crystals Black 946 776 Fire glass crystals Cop...

Page 30: ...30 Regency Plateau PTO30 Outdoor Gas Fireplace NOTES ...

Page 31: ...lling dealer is responsible for all in field service work carried out on your Regency product FPI will not be liable for results or costs of workmanship from unauthorized service persons or dealers At all times FPI reserves the right to inspect product in the field which is claimed to be defective All claims must be submitted to FPI by authorized selling dealers It is essential that all submitted ...

Page 32: ... ___________________________________________________________ Phone ___________________________________________________________ Date Installed ______________________________________________________ Serial No __________________________________________________________ Register your Regency warranty online www regency fire com Reasons to register your product online today View and modify a list of all...

Reviews: