background image

8" dia.

Flue pipe

5” dia. flue pipe

spring spacer

(Part# 946-623/P)

AstroCap XL

Wall Thimble

(required in Canada only)

Vinyl Siding

Standoff

Regency Direct  Vent System (Flex)

Horizontal Terminations Only

These venting systems, in combination with the P40 Direct Vent Gas 
Fireplace, have been tested and listed as a direct vent heater system 
by Warnock Hersey. The location of the termination cap must conform 
to the requirements in the Vent Terminal Locations diagram.

FPI Direct Vent (Flex) System Termination Kits include all the parts 
needed to install the P40 using a fl exible vent.

Snorkel Terminations

Snorkel Terminations:

For installations requiring a vertical rise on the exterior of the building, 14-
inch and 36-inch tall Snorkel Terminations are available. Follow the same 
installation procedures as used for standard Horizontal Termination. 
NEVER install the snorkel upside down.

Below Grade Snorkel Installation (Dura-Vent Only)

If the Snorkel Termination must be installed below grade, i.e. basement 
application, proper drainage must be provided to prevent water from 
entering the Snorkel Termination. Refer to Rigid Pipe Installation 
instructions for details. Do not attempt to enclose the Snorkel within the 
wall, or any other type of enclosure.

Drywall

Mantel Clearances

2

0

12

6

4

8

10

0

Side View

Top of

Louvers

13" (330mm)

1" (25mm)

8”(203mm)

A

Standoff

B

C

D

Non-Combustible

Header

Non-Combustible

Facing

14

To Floor

Note:  If desired a non-combustible mantel may be installed at a 

lower height.

Note:  Ensure the paint that is used on the mantel and the facing 

is “heat resistant” or the paint may discolour.

8” Side Wall

7¼”

2"

Mantel

leg

Mantel

leg

P40

Allowable mantel leg

projection.

6”

1-1/2"

Mantel Leg Clearances

Combustible mantel leg clearances as per diagram below:
Clearances are from the fi nished edge of the unit or installed front.

Maximum 
1-1/2” projection at 2” 
minimum clearance.

Mantel Clearances

A

B

C

D

Front

33” (838mm)

21” (356mm)

17” (254mm)

12” (178mm)

P40 Gas Fireplace

Combustible Mantels

Because of the extreme heat this fi replace emits, the mantel 
clearances are critical.

 Combustible mantel clearances from top of 

the louvers are shown in the diagram below. Mantel may be installed 
anywhere in the shaded area or higher.

FPI Kit # 

Length 

Contains:

#946-618

6 Feet

1)

 

8” fl exible outer liner (Kit length)

2)

 

5” fl exible inner liner (Kit length)

3)

 spring 

spacers 

(3)

4)

 thimble 

(2)

5)

 

AstroCap

 termination cap (1)

6)

 screws 

(12)

7)

 

tube of Mill Pac (1)

8)

 plated 

screws 

(8)

9)

 

S.S. screws #8 x 1-1/2” drill point, (4)

10)

  vinyl siding standoff

#946-616

10 Feet

Notes: 
1) 

Liner sections should be continuous without any joints or seams.

2) 

Only Flex pipe purchased from Regency may be used for Flex 
installations.

3) 

Horizontal sections must be supported every 3 feet.

47

June 2007 Regency Product Specifi cations Book

Gas Fireplaces

Gas Fir

eplaces

Summary of Contents for P40-LP1

Page 1: ...26mm Framing Dimensions Description P40 G Framing Width 40 1 2 1029mm H Framing Height 42 1 2 1080mm Hearth I Framing Depth 20 1 16 508mm J Corner Wall Length 50 5 8 1286mm K Corner Facing Wall Width 71 5 8 1524mm L Minimum Height to Combustibles 51 7 8 1318mm M Vent Centerline Height 45 3 8 1153mm N Non Combustible Facing Height 10 1 4 260mm O Gas Connection Height 1 1 2 38mm P Gas Connection Ins...

Page 2: ...stalled front C Ceiling 39 991mm Top of installed unit D Mantel Depth 13 330mm Maximum Additional on this page E Alcove Width 56 1422mm Sidewall to Sidewall Minimum F Alcove Depth 36 914mm Front to back wall Maximum G Hearth Height 1 1 2 39mm Floor to top of Hearth Hearth must not be higher than base of firebox H Hearth Width 40 1016mm Edge to Edge of Hearth I Hearth Depth 16 406mm Front of Hearth ...

Page 3: ...Top of Louvers 13 330mm 1 25mm 8 203mm A Standoff B C D Non Combustible Header Non Combustible Facing 14 To Floor Note If desired a non combustible mantel may be installed at a lower height Note Ensure the paint that is used on the mantel and the facing is heat resistant or the paint may discolour 8 Side Wall 7 2 Mantel leg Mantel leg P40 Allowable mantel leg projection 6 1 1 2 Mantel Leg Clearanc...

Page 4: ...tal sections must be supported every 3 feet Firestops are required at each floor level and whenever passing through a wall Maintain clearances to combustible materials Minimum of 1 pipe section between any elbows Note Must use optional rigid pipe adapter when using Rigid Pipe Part 770 994 Maximum 40 ft 12 2m Minimum 8 9 2 6m Max 10 3m centerline to centerline Minimum 12 305mm Maximum 28 ft 8 5m 0 ...

Page 5: ...Max 5 Min F 5 Min 8 Max 6 Min Vertical Venting with Three 3 90 Elbows Two 45 elbows One 90 elbow Option V H H1 V V1 Maximum total pipe length of all sections must not exceed 30 feet Total horizontal sections must not exceed 8 feet Minimum of 1 pipe section between any elbows When the total vertical exceeds total horizontal by 3x then the vent restrictor must be set to 1 A 0 Min 2 Max 3 Min B 1 Min...

Page 6: ...1 The darker shaded area 6 8 2 0 4 10 12 16 18 14 20 26 28 22 24 30 in the diagram shows allowable venting configurations with the Vent Restrictor on Set 2 Note Must use optional rigid pipe adapter Part 770 994 when using Rigid Pipe Maintain clearances to combustibles Horizontal vent must be supported every 3 feet Minimum of 1 pipe section between any elbows Firestops are required at each floor leve...

Page 7: ...h Three 3 90 Elbows Two 45 elbows One 90 elbow Option V H V V1 H H1 Maximum total pipe length of all sections must not exceed 30 feet Total horizontal sections must not exceed 9 feet Minimum of 1 pipe section between any elbows When the total vertical exceeds total horizontal by 3x then the vent restrictor must be set to 1 A 0 Min 1 Max 1 Min 1 Max B 1 Min 2 Max 3 Min 3 Max C 2 Min 2 Max 5 Min 4 M...