P36-10 Zero Clearance Direct Vent Gas Fireplace |
9
|
9
installation
HEATWAVE
DUCT SYSTEM
OPTIONAL KIT #946-556
The
HeatWave
Air Duct Kit increases the
effectiveness of your fireplace by dispersing warm
air from the fireplace to remote locations in the same
room or other rooms in your home.
Up to two kits may be installed on the fireplace.
Please Note: Only 1 HeatWave kit may be oper-
ated at one time. This includes the internal blower
option as well.
Diagram 1
This includes:
1) Clocking the appliance to ensure the correct
firing rate (rate noted on label 30,000 Btu/h)
after burning appliance for 15 minutes.
2) If required, adjusting the primary air to ensure
that the flame does not carbon. First allow the
unit to burn for 15-20 min. to stabilize.
CAUTION:
Any alteration to the product that causes sooting
or carboning that results in damage is not the
responsibility of the manufacturer.
7) We recommend that you plan your installation on
paper using exact measurements for clearances
and floor protection before actually installing this
appliance. Have a qualified inspector, dealer, or
installer review your plans before installation.
Note: For vent terminations see the
"Exterior Vent Termination
Locations" section.
MANUFACTURED
MOBILE HOME
ADDITIONAL
REQUIREMENTS
1) Ensure that structural members are not cut or
weakened during installation.
2) Ensure proper grounding using the #8 ground
lug provided. See the "Alternate Wiring Diagram
for Wall Switch" section.
5) This appliance is Listed for bedroom installations
when used with a Listed Millivolt Thermostat.
Some areas may have further requirements,
check local codes before installation.
6) The P36 Direct Vent Gas Fireplace is approved
for alcove installations, which meet the
clearances listed on this page.
A) Flat on Wall
B) Flat on Wall Corner
C) Recessed into Wall/Alcove
D) Corner
OPTIONAL
HEAT RELEASE KIT
#946-570
The Heat Release Kit expels warm air from the
fireplace to the outside of the building, allowing
the fireplace to be operated with less heat entering
the room. The kit may be used on either the left or
right side.
The
HeatWave
Duct Kit has different
clearance and framing requirements, check
the
HeatWave
manual for details.
INSTALLATION
CHECKLIST
1) Locate appliance. Refer to the following
sections:
a) Locating Your Gas Fireplace
b) Clearances
c) Combustible Mantel Clearances
d) Framing & Finishing
e) Venting
2) Assemble Top Standoffs and Top Facing
Support and Side Nailing Strips (Refer to the
"Unit Assembly Prior to Installation" section).
NOTE: Must be done before installing unit into
fireplace.
3) Install vent (Refer to the "Venting" sections).
4) Install 4-AA batteries into receiver. Hook
receiver to wire marked receiver. This will
enable operation of the appliance manually
when positioned in the "ON" position.
5) Make gas and electrical connections. Test the
pilot. Must be as per diagram (Refer to the "Pilot
Adjustment " section).
Convert to propane if desired (Refer to the "SIT
Valve Description" section).
6) Install standard and optional features. Refer
to the following sections where applicable:
a. Optional Brick Panels
b. Log Set Installation
c. Standard Flush Door
d. Vignette Faceplate
e. Remote Control
f. Remote Receiver & Wall Switch
g. Fan Installation
7) Final check.
Before leaving this unit with the customer, the
installer must ensure that the appliance is firing
correctly and
operation fully explained to
customer.
LOCATING YOUR
GAS FIREPLACE
1) When selecting a location for your fireplace,
ensure that the clearances outlined on this page
are met.
2) Provide adequate clearances for servicing.
3) The appliance must be installed on a flat, solid,
continuous surface (e.g. wood, metal, concrete).
This may be the floor, or raised up on a platform
to enhance its visual impact. If the appliance is
going to be installed on carpeting, combustible
linoleum tile or other combustible material other
than wood flooring, the appliance must be
installed on a metal or wood panel extending
the full width and depth of the appliance.
4) The P36 Direct Vent Gas Fireplace can be
installed in a recessed position or framed out
into the room as in A, B, C, D. See
Diagram 1.