Regency
®
P33 Gas Log Fireplace
28
18)
Reverse steps 5) to 2).
19)
Attach clear label "This unit has been
converted to LPG" near or on top of the
serial # decal.
20)
Replace yellow "Natural Gas" label with
red "LPG" label.
21)
Check LPG aeration setting.
22)
Check
for
gas
leaks.
23)
Check inlet and outlet pressures.
24)
Check operation of fl ame control.
25)
Check for proper fl ame appearance and
glow on logs.
26)
Check manual for venting confi gurations
(refer to venting section).
15)
Using the Allen wrench as shown in
Fig.4, rotate the screw clockwise until
snug, do not overtighten.
Fig.4
WARNING!
Do not overtighten the screw.
Recommended to
grip the wrench by the short side.
16)
Verify that if the conversion is from NG to
LPG, the screw must be re-assembled
with the red o-ring visible (Fig. 5).
17)
Re-assemble the black protection cap
(Fig. 6).
WARNING!
Also check that the pilot and main
burner injectors
are appropriate for the gas type.
LPG Configuration
Red o-ring visible
Fig.5
Fig. 6
Installer Notice:
These instructions must
be left with the appliance.
INSTALLATION