P33CE Direct Vent Gas Fireplace
13
INSTALLATION
FRAMING DIMENSIONS
* Measured from base of unit
M
L
K
P Q
O
N
Opening for gas
connection
J
I
Floor
DETAIL N
SCALE 1 : 6
2X4 HEADER
N
Non-combustible
Header
(steel stud
on edge)
G
H
I
J
NOTE:
If this is an outside corner, the
minimum distance between the vent
and the outside corner is 6" (15cm)
with AstroCap termination cap or 12"
(30cm) with Rigid Vent termination cap.
(For example Dura-Vent)
Framing Dimensions
Description
P33CE
P33CE
With Non-Combustible Board Only
(i.e. Painted Finish)
With Tile, Stone, Brick, Slate,
Modera Mantel, Verona Surround
or other Non-Combustible fi nish
G
Framing Width
35"(889mm)
35"(889mm)
H
Framing Height *
31-3/4" (806mm)
31-3/4" (806mm)
I
Framing Rise from Floor
0"
(when not using a surround / mantel)
0"
2" min (w/ Modera Mantel)
3-5/16" min (w/ Verona Surround)
J
Framing Depth Vertical
Horizontal
23-1/4" (578mm)
Vertical Rise
20-1/4" (502mm)
Rigid
/ 16-1/2" (406mm)
Flex
22-3/4" (578mm)
Vertical Rise
19-3/4" (502mm)
Rigid
/ 16" (406mm)
Flex
K
Corner Wall Length
39-1/4" (988mm)
38-15/16" (988mm)
L
Corner Facing Wall Width
55-1/2" (1410mm)
54-1/2" (1410mm)
M
Framed Chase Ceiling*
36" (914mm)
Rigid
32" (812mm)
Flex
36" (914mm)
Rigid
32" (812mm)
Flex
N
Vent Centerline Height*
30" (762mm)
Rigid
26" (660mm)
Flex
30" (762mm)
Rigid
26" (660mm)
Flex
O
Gas Connection Height*
1 1/2" (38mm)
1 1/2" (38mm)
P
Gas Connection Inset*
7-3/16" (183mm)
7-3/16" (183mm)
Q
Gas Connection Width*
3" (76mm)
3" (76mm)