Regency
®
P33-5 Zero Clearance Direct Vent Gas Fireplace
5
SAFETY LABEL
SAFETY LABEL
This is a copy of the label that accompanies each P33-5 Zero Clearance Direct Vent Gas Fireplace. We have
printed a copy of the contents here for your review. The safety label is located on the front inside base of the
unit, visible when the bottom louver is open.
NOTE:
Regency
®
units are constantly being improved. Check the label on the unit and if there is a difference,
the label on the unit is the correct one.
For the State of Massachusetts, installation
and repair must be done by a plumber or
gasfi tter licensed in the Commonwealth of
Massachusetts.
For the State of Massachusetts, fl exible
connectors shall not exceed 36 inches in
length.
For the State of Massachusetts, the appli-
ances individual manual shut-off must be a
t-handle type valve.
The State of Massachusetts requires the
installation of a carbon monoxide alarm in
accordance with NFPA 720 and a CO alarm
with battery back up in the same room where
the gas appliance is installed.
DO NOT REMOVE THIS LABEL / NE PAS ENLEVER CETTE ÉTIQUETTE
421
Minimum supply pressure
Manifold pressure high
Manifold pressure low
Orifice size
Minimum input
Maximum input
Altitude
Minimum input
Maximum input
Orifice size
Altitude
NATURAL GAS:
Model P33-NG5
PROPANE:
Model P33-LP5
Minimum supply pressure
Manifold pressure high
Manifold pressure low
Orifice size
Minimum input
Maximum input
Altitude
DOOR SEAL: Please check that
the door is properly sealed
FPI Fireplace Products International Ltd.
Delta, BC, Canada
Minimum Clearances to Combustibles
Degagement Minimum De Materiaux Combustibles
0" Clearance to
combustibles from:
Mantel Clearances from Top:
Side Wall Clearance from Side
Facing
Top, sides, bottom and rear of unit
(A) Min. 7" (177mm)
B) 7.5"(191mm)
C) Min 1” (26mm)
w/Faceplate
Min 0” (0mm)
All Other Applications
with Flush or Bay Front
Clearance to finished floor from
Base:
Max. Depth 36" (914mm)
Min. Width 48" (1219mm),
Min. Height 59“ (1499mm)
Alcove Clearances for Bay &
Flush Louvers:
(
See Instruction Manual for
Detailed Instructions)
Serial No./ No de serie
919-245
5"
WC
(1.25 kPa)
3.5"
WC
(0.87 kPa)
1.6"
WC
(0.39 kPa)
# 44
DMS
0-2000 ft/pi
(0-610 m)
14,000 Btu/h (4.1 kW)
20.000 Btu/h (5.86 kW)
(3.07 kW)
(6.15 kW)
10,500 Btu/h
# 45
DMS
2000-4500 ft/pi (610-1372m)
21,000 Btu/h
APPAREIL FONCTIONNANT AU NATURAL GAS
CONCU POUR ETRE POELE:
Pression d'allimentation minimum
Pression a la tubulure d' chappement lev e
Pression a la tubulure d' chappement basse
Grandeur de l'injecteur
D bit Califorique minimum selon
D bit Caliorfique maximum selon
l'altitude
Modéle P33-NG5
é
é
é
é
é
é
APPAREIL FONCTIONNANT AU PROPANE
CONCU POUR ETRE POELE:
Pression d'allimentation minimum
Pression a la tubulure d' chappement lev e
Pression a la tubulure d' chappement basse
Grandeur de l'injecteur
D bit Califorique minimum selon
D bit Caliorfique maximum selon
l'altitude
Modéle P33-LP5
é
é
é
é
é
é
VENTING: Use listed Simpson Dura-Vent GS System or Regency Direct Vent System. Only for direct discharge without duct connection. This appliance
must be installed in accordance with the manufacturer's installation instructions and with local codes, if any; if not, follow the current ANSI Z223.1 in the
USA or the current CAN 1-B149 in Canada. For Manufactured Home Installation: This Direct Vent System Appliance must be installed in accordance with
the manufacturer's installation instructions and Manufactured Home Construction and Safety Standard Title 24 CFR, Part 3280, or the current Standard
for Fire Safety Criteria for Manufactured Home Installations, Sites, and Communities ANSI/NFPA 501A, and with CAN/CSA Z240 MH Mobile Home
Standard in Canada.
VENTILATION : Système de GS de Dura-conduit de Simpson énuméré par utilisation ou circuit de mise à l'air libre direct de Regency.
Seulement pour la décharge directe sans connexion de conduit. Cet appareil \ndoit être installé selon les instructions d'installation du fabricant
et avec des codes locaux éventuels ; sinon, suivez la norme ANSI actuelle Z223.1 dans \nLes Etats-Unis ou le courant PEUVENT 1-B149 dans
le Canada. Pour l'installation à la maison manufacturée : Cet appareil direct de circuit de mise à l'air libre doit être installé selon\n les instructions
d'installation du fabricant et le titre à la maison manufacturé 24 CFR de construction et de norme de sécurité, la partie 3280, ou la norme actuelle \npour
des critères de sécurité incendie pour les installations, les sites, et les Communautés à la maison manufacturés ANSI/NFPA 501A, et avec la caravane
résidentielle de CAN/CSA Z240 MH \nNorme dans le Canada.
Fan (Part # 432-917) Option: HeatWave Kit # 946-556
This vented gas fireplace heater is not for use with air filters.
Ne pas utiliser de filtre à air avec ce foyer au gaz à évacuation.
MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES AFTER FIRST SALE
.
Listed:
Certified for/Certifi e pour:
VENTED GAS FIREPLACE HEATER
CANADA and U.S.A.
é
CAN/CGA-2.17-M91(R2009)
Tested to:
Conforms to:
Certified to:
ANSI Z21.88-2009
CSA 2.33-2009
Model/Modele:
P33-NG5
Model/Modele:
P33-LP5
Electrical /
115VAC, 1.13 A, 60Hz.
Électrique
Made in Canada/
Fabrique au Canada
Duplicate S/N
B
B
30"
Ceiling
W
all
W
all
A
Minimum clearance of Vent
Terminal to Outside Corner &
Inside Corner: 6"/150mm
Horizontal Terminations require
the use of the
(Part # 946-523)
AstroCap
TM
11"
WC
(2.74 kPa)
10"
WC
(2.49 kPa)
6.4"
WC
(1.59 kPa)
# 55
DMS
0-4500
ft/pi
(0-1372 m)
14,500
Btu/h
(4.24 kW)
18,000
Btu/h
(5.28 kW)
D bit Caliorfique minimum selon
Grandeur de l'injecteur
l'altitude
é
é
D bit Califorique maximum selon
Model P33-NG5 convertible to 17,500 Btu for Altitude 0- 4500ft/pi
Orifice size
Maximum input
Minimum input
# 47
DMS
17,500 Btu/h (5.13 kW)
9,800
Btu/h
(2.87 kW)
Grandeur de l'injecteur
D bit Caliorfique maximum selon
D bit Califorique minimum selon
é
é
Model P33-LP5 convertible to 15,500 Btu for Altitude 0- 4500ft/pi
Orifice size
Maximum input
Minimum input
# 56
DMS
15,500
Btu/h (4.54 kW)
9,000
Btu/h
(2.64 kW)
Grandeur de l'injecteur
D bit Caliorfique maximum selon
D bit Califorique minimum selon
é
é
(For use with Faceplate)
(For use with Faceplate)
A
B
C
B
4001172
421
NOT FOR USE WITH SOLID FUELS. /
NE PAS UTILISER AVEC DES COMBUSTIBLES
SOLIDE.