INSTALLATION
Diagram 1
Diagram 2
FLUSH LOUVERS
1)
Install the top louver by sliding the two
bracket clips into the brackets located
underneath the top of the fi rebox.
2)
Install the bottom louver by folding the louver
down and then sliding the Bottom Louver
bracket down onto the 2 pins on the base
of the unit (Diagram1). Secure with 1 screw
(Diagram 2).
Note: Top and
bottom louvers
are different.
3)
Open the bottom louver. Pull the Burner
ON/OFF control box from inside the bottom
of the fi replace and position the slots in the
bracket over the 2 screws on the left side
of the bottom louver. Push down to lock into
place. Tighten the screws.
Screws on
louver bracket
Burner ON/OFF control box attached to
bottom fl ush louver.
Burner ON/OFF
control box