background image

919-406b

MODEL:    Kingston F3502B

Freestanding Wood Fire

12.20.16

Installer

: Please complete the details on the back cover 

and leave this manual with the homeowner.

Homeowner:

 Please keep these instructions for future reference.

Owners & 

Installation Manual

www.regency-fire.com.au

FPI - FIREPLACE PRODUCTS AUSTRALIA PTY LTD.  

1-3 CONQUEST WAY HALLAM VICTORIA 3803

Summary of Contents for Kingston F3502B

Page 1: ...ease complete the details on the back cover and leave this manual with the homeowner Homeowner Please keep these instructions for future reference Owners Installation Manual www regency fire com au FPI FIREPLACE PRODUCTS AUSTRALIA PTY LTD 1 3 CONQUEST WAY HALLAM VICTORIA 3803 ...

Page 2: ... a catalytic combustor which needs periodic inspection and replacement for proper operation It is against the law to operate this wood heater in a manner inconsistent with operating instructions in this manual or if the catalytic element is deactivated or removed CAUTION BURN UNTREATED WOOD ONLY OTHER MATERIALS SUCH AS WOOD PRESERVATIVES METAL FOILS COAL PLASTIC GARBAGE SULPHUR OR OIL MAY DAMAGE T...

Page 3: ...Installation replacement 12 Brick Installation 13 Fan Installation 14 240V Fan 14 Fan operation 14 Operating Instructions 15 Draft Control 15 Important 15 First Fire 15 Fan Operation 16 Ash Disposal 16 Safety Guidelines and Warnings 16 Maintenance 18 Creosote 18 Door Catch Adjustment 18 Door Gasket 18 Glass Maintenance 18 Wood Storage 18 Glass Replacement 18 Catalytic combustor 19 Bypass door gask...

Page 4: ...a copy of the data badge that accompanies each F3502B Freestanding Wood Fire We have printed a copy of the contents here for your review NOTE Regency units are constantly being improved Check the data badge on the unit and if there is a difference the label on the unit is the correct one ...

Page 5: ...F3502B Freestanding Woodfire 5 5 dimensions UNIT DIMENSIONS ...

Page 6: ...ood fire is not to be connected to any air distribution duct CAUTION Do not alter or makeshift flue or install Install as per Manual MODULAR INSTALLATION OPTIONS WARNING ONLY USE SPECIFIED COMPONENTS The following items are required when assembling your Regency Stove F3502B unit the Rear Heat Deflector is supplied with the stove but if you choose not to use it you must use the Airmate instead Modu...

Page 7: ...es of the rear heat shield See Diagrams 2 3 Rear Heat Deflector Assembly for F3502B The rear heat deflector is supplied with the stove and must be installed unless the optional airmate has been selected It stops the heat radiated from the flue collar from overheating the rear wall The rear heat deflector is installed on top of the rear heat shield as shown in Diagram 4 Side Shield Adjustment The l...

Page 8: ...eck with your local inspector Minimum Alcove Clearance to Combustible Materials The Regency Freestanding models have been alcove approved and must be installed with a listed double wall connector to the ceiling level Note Minimum alcove ceiling height 83 2108 mm Vertical Termination H Maximum depth of alcove 48 1219mm G Minimum width of alcove 60 1524mm B A D E H G ROOF EXIT WALL EXIT ROOF EXIT WA...

Page 9: ...cal Rise THRU WALL INSTALLATION Minimum vertical of 900mm before any 90 If using 45 refer to diagram Horizontal Maximum of 900mm with 6 35mm rise per 0 3m NOTE Recommend using 2 45º instead of 90º to improve draft and performance as per diagram Min 900 mm Vertical Rise 200mm ...

Page 10: ...al ie tile concrete board or as defined by local codes extending beneath the heater as follows From sides 200mm From Front 300mm from Glass From Back of Appliance 12 mm 12mm from outer rear heat shield to edge of cement sheet Floor protection must be minimum of 6mm thick 1060mm x 1000mm size with a thermal conductivity of 0 8W mºK ...

Page 11: ...l burning appliance 1 With your location already established cut and frame the roof hole It is recommended that no ceiling joist be cut for flue and support box installation If it is necessary to cut them the joist must be made structurally sound 2 Install radiant shield and support from above 3 Stack the flue pipe onto your finish support to a minimum height of 1m above the roof penetration or 0 ...

Page 12: ... Install new defector and hand tighten bolts Ensure positive location of the deflector prior to hand tightening WARNING Operation of the unit with out proper installation of smoke deflector will void warranty Smoke deflector installed with 2 bolts Note This is a view from inside the firebox looking out Ensure defector is seated so bolts are situated at the top of the keyhole before tightening Hand...

Page 13: ...ebricks from inside unit 2 Remove Lyotherm sheet from mailer tube and install on base of firebox as shown below NOTE The AD brick covers the Ash Dump hole that is used when the Ash Drawer Kit is installed Lyotherm sheet Final Install 3 Order of firebrick install a Rear Firebrick b Firebox floor install brick over Lyothern Sheet c Right and left side Firebricks AD brick Fire bricks Quantity Size 1 ...

Page 14: ...oser to the stove and re install the fan MANUAL To manually operate the fan system push the bottom switch to MAN and the top switch to either HIGH or LOW This will bypass the sensing device and allow full control of the fan Switching from AUTO to MAN or HIGH to LOW may be done anytime CAUTION Label all wires prior to disconnec tion when servicing controls Wiring errors can cause improper and dange...

Page 15: ...For the first few days the stove will give off an odour from the paint This is to be expected as thehightemperaturepaintbecomesseasoned Windows and or doors should be left open to provide adequate ventilation while this tem porary condition exists Burning the stove at a very high temperature the first few times may Left Open Right Closed Back Closed Front Open Primary Air Damper Catalyst Bypass Co...

Page 16: ... smoke spillage as this may set off a false alarm 5 Do not overfire heater If the flue connector flue baffle or the stove top begin to glow you are over firing Stop adding fuel and close the draft control Over firing can cause extensive damage to your stove including warping and premature steel corrosion Over firing will void your warranty 6 Do not permit creosote or soot build up in the flue syst...

Page 17: ...a partially open and partially closed position after a hot fire has been started Masking Soot Combustor has not maintained a light off Burning coal will cause a sulfur based compound to coat the catalyst Place combustor in a partially open and partially position after a hot fire has been started to burn off the soot accumulation Revert to burning wood and fire the combustor to elevated temperature...

Page 18: ...erytwomonthsduring the heating season to determine is a creosote buildup has occurred 6 Have chimney system and unit cleaned by competent chimney sweeps twice a year during the first year of use and at least once a year thereafter or when a significant layer of creosote has accumulated 3 mm 1 8 or more it should be removed to reduce the risk of a chimney fire DOOR CATCH ADJUSTMENT The door Catch m...

Page 19: ...th of your heating season and how often you use your stove Proper maintenance will increase the combustor s effectiveness and prevent many problems Inspect your combustor before each heating season and during the season if your stove s performance seems to change This catalytic heater is equipped with a temperature probe to monitor catalyst operation Properly functioning combustors typically maint...

Page 20: ... the door TO REPLACE THE COMBUSTOR First clean the combustor area and the area around the by pass use a vacuum cleaner Lift the new combustor into position with the stainless flanges on each end facing forward The combustor should slide easily into position you may need to pinch down the top center with your finger to start gently push as far to the back of the stove as possible Replace the flame ...

Page 21: ...y to reveal gasket 3 Loosen the 3 rear nuts then remove 3 front nuts Support the Bypass Door from the front back and slide forward to remove Bypass Door Assembly Note if any of the bolts become damaged the bolt bracket assemblies may be replaced see next page Important Bypass door is very heavy 18 lbs use caution when servicing 6 Reverse steps to reinstall ensure the pass rod is seated with the ch...

Page 22: ...o the air channel on right BYPASS DOOR BOLT BRACKET ASSEMBLY REPLACEMENT If any of the bolts used to secure the bypass door become damaged the bypass door bolt bracket assembly can be replaced 1 Allow the stove to burn out and cool down until cool to touch 2 Remove bypass door before attempting to remove bolt bracket assembly see detailed instructions on previous page 3 Open stove door and remove ...

Page 23: ...ect condition and seal of Glass Gasket Door Gasket Perform paper test replace gasket if required Paper Test Test the seal on the loading door with a paper bill Place a paper bill in the gasket area of the door on a cold stove Close the door Try to remove the paper by pulling The paper should not pull out easily if it does try adjusting the door latch if that doesn t solve the problem replace the d...

Page 24: ...042 035 Flame shield and mixer 815 557 Rear Deflector 042 017 Gasket Firebox Floor 948 223 Regency Logo Plate Part Description 8 051 018 Handle holder 9 042 520 Cast door assembly 5 051 530 Catalytic Combustor Assembly not shown 033 953 Airtube 1 x 23 long 10 904 245 10 16 x 1 2 SDS HEX HD 11 904 530 Screw 1 4 20 x 1 2 LG 12 042 532 Pedestal assembly 13 051 067 Thermometer 936 074 Gasket Bypass Do...

Page 25: ...BLANK SIZE PART MAT L ANGULAR DIMENSIONS TOLERANCES UNLESS OTHERWISE STATED PROJECTION 3RD ANGLE 1 0 031 FIREPLACE PRODUCTS INTERNATIONAL 06 MAY 2013 N A WAYNE THURBER FIRE BRICK ASSEMBLY 6 3 4 5 1 2 6 802 146 1 1 750 x 9 000 BRICK 5 802 165 1 7 375 x 4 500 CUT BRICK 4 802 128 1 1 875 x 4 500 BRICK 3 802 147 1 3 500 x 4 500 BRICK 2 802 104 1 4 000 x 9 000 BRICK 1 902 111 15 9 000 x 4 500 STANDARD ...

Page 26: ...andle assembly 4 940 416 P Door glass 5 943 243 7 8 flat window gasket per 5ft required 6 042 020 5 8 Gasket Retainer Part Description 7 846 530 5 8 Medium Door gasket kit 8 042 021 Gasket bracket 9 904 513 Hex bolt 1 4 20 x 3 4 LG 10 904 525 Washer 1 4 split lock 11 904 149 SMS 8 18 x 3 8 LG 12 904 146 Screw 10 x 1 2 self tap pan hd philips 13 904 015 1 4 20 x 1 2 pan hd phil 14 948 155 Hinge pin...

Page 27: ...F3502B Freestanding Woodfire 27 27 notes ...

Page 28: ...Heatshields Pedestal 1 All Baffles Steel Ceramic Vermiculite 1 All castings firebox surrounds doors panels etc 1 All Electrical Fans wiring switches etc Fan only 1 Glass Crazing 1 Catalyst Assembly see below for specific details 6 Years Prorated 3 Flue components 1 Firebricks Nil Nil After the original warranty coverage for any of the parts above have expired any repair and or replacement parts pu...

Page 29: ...ults or costs of workmanship of unauthorised FPI dealers or agents in the negligence of their service work Additional service fees may apply if you are seeking warranty service from a dealer other than the dealer from whom you originally purchased the product At all times FPI reserves the right to inspect reported complaints on location in the field claimed to be defective and determine whether th...

Page 30: ...iances Any unit showing signs of neglect or misuse will not be covered under the terms of this warranty policy and may void this warranty This includes units with rusted or corroded fireboxes which have not been reported as rusted or corroded within three 3 months of installation purchase Any alteration to the unit which causes sooting or carboning that results in damage to the exterior fascia or ...

Page 31: ...t the option of the supplier one or more of the following i replacement of the goods or the supply of equivalent goods ii the repair of the goods iii the payment of the cost of replacing the goods or of acquiring equivalent goods or iv equivalent goods or v the payment of the cost of having the goods repaired b To the extent that services supplied by the supplier are services other than services o...

Page 32: ...oducts Australia Pty Ltd does not provide installation services Fireplace Products Australia Pty Ltd 1 3 Conquest Way Hallam VIC Australia 3803 Phone 61 3 9799 7277 Fax 61 3 9799 7822 To obtain warranty service in Western Australia and or New Zealand please contact one of our authorised distributors in those areas Western Australia Air Group Australia 28 30 Division St Welshpool WA Australia 6106 ...

Page 33: ...order for us to serve you better Warranty Registration Form or Register online immediately at the above Web Site Warranty Details Serial Number required Purchase Date required mm dd yyyy Product Details Product Model required Dealer Details Dealer Name required Dealer Address Dealer Phone Installer Date Installed mm dd yyyy Your Contact Details required Name Address Phone Email For purchases made ...

Page 34: ...34 F3502B Freestanding Woodfire 34 ...

Page 35: ...ic Converter must not have been mechanically abused nor must the wrong fuels have been used in the appliance If after three years the Versagrid Catalytic Converter fails to function the Prorated Warranty will allow replacement at the following special price schedule Year 4 90 Year 5 100 Year 6 110 Year 7 current retail price Conditions 1 and 2 also apply to the Prorated portion of the warranty The...

Page 36: ...Dealer Name Address _______________________________________________ ___________________________________________________________________ Installer ____________________________________________________________ Phone ____________________________________________________________ Date Installed _______________________________________________________ Serial No _____________________________________________...