F3502B Freestanding Woodfire |
23
|
23
maintenance
DOOR CATCH
ADJUSTMENT
After a few fires, the door catch may require adjustment to renew a tight seal,
as the door gasket will compress. Removal of a shim, shown in the diagram
below, will allow the catch to be moved closer to the door frame, creating a
tighter seal.
To remove a shim, loosen the 2 bolts to create clearance behind catch. Place
a screwdriver in the slot of the shim and slide out. Retighten bolts.
Note: Keep the shims - they may be required in the future when the gasket
is replaced.
Annual Maintenance
Completely clean out entire unit
Annually
Inspect air tube, Catalytic Combustor and bricks
Replace any damaged parts.
Adjust door catch assembly
If unable to obtain a tight seal on the door - replace door gasket seal.
Readjust door catch after new gasket installed.
Inspect condition and seal of:
Glass Gasket
Door Gasket
Perform paper test - replace gasket if required
Paper Test
Test the seal on the loading door with a paper bill.
Place a paper bill in the gasket area of the door on a cold stove.
Close the door.
Try to remove the paper by pulling.
The paper should not pull out easily, if it does, try adjusting the door latch, if that
doesn't solve the problem replace the door gasket.
Check and lubricate door hinge + latch
Use only high temperature anti seize lube. (ie. never seize)
Check glass for cracks
Replace if required.
Clean blower motor
Disconnect power supply.
Remove and clean blower.
*DO NOT LUBRICATE*
Inspect and clean chimney
Annual professional chimney cleaning recommended.
DOOR HINGE
ADJUSTMENT
If the door hinge ever requires adjustement, ensure that the bolt is put on
hand tight and tightened a further 1/2 turn using a wrench.
Do not overthighten as this can damage the bolt or nutsert.
Note: Some models may only have 1 bolt at the top. This version shows 2
top bolts.
Door Hinge
bolts