14
Regency I43-1 ULTIMATE Gas Inbuilt Fireplace
INSTALLATION
DOOR INSTALLATION
1)
Open the two side doors.
2)
Slide the door onto the two hinge pins making sure the
two pieces are fl ush together. See diagram 1.
3)
Close the door. The latch plate must be centered around
the alignment pin. See diagram 2. If the latch plate inter-
feres with the corner of the stove you may want to angle
the plate slightly so the door closes more easily.
4)
The latches should already be at the proper setting. If
they are too hard or too easy to close, you may want to
adjust them by turning the latch. See diagram 3.
5)
Remove the blue plastic protective coating.
Diagram 1
Diagram 3
Diagram 2
6)
Test the seal around the door by placing a piece of paper
between the unit and the door, close the door and try to
pull the paper out. If it slips out easily, then the door is
not properly sealed. Turn the adjustable catch to tighten
or loosen the latch. See diagram 3.
Note: The door latch may require adjustment as the door
gasket material compresses after a few fi res and
after glass replacement. Turn the latch to tighten
or loosen the latch.
Thermostat Wire Table
Recom-
mended
Maximum
Lead
Length
(Two-Wire)
When Us-
ing Wall
Ther-
mostat
(CP-2
System)
Wire Size
Max. Length
14 GA.
16 GA.
CAUTION
Do not connect the millivolt wall
thermostat wires to the 240V wires.
OPTIONAL WALL THERMOSTAT
A wall thermostat may be installed if desired. Connect the wires
as per the wiring diagrams. Note that the wires are connected
to the "TH" on the gas valve. Use chart below to determine
the maximum wire length:
Note: Preferable if the thermostat is installed on an in-
terior wall.
Regency offers a programmable thermostat but any CSA, ULC
or UL approved millivolt thermostat, 250-750 millivolt rated
non-anticipator type thermostat may be used.