WARRANTY

WARRANTY

Revised: 01-04-07

Regency Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects 

each unit thoroughly before it leaves our door.  

FPI Fireplace Products International Ltd.

 is pleased to extend this limited lifetime warranty to the  

original purchaser of a Regency Product. This warranty is not transferable.

The Warranty:  

Lifetime

Covered under the agreement are the following  components:

Firebox, ceramic baffl e, vermiculite baffl e, steel baffl es (H2100), convector airmate, castings, ashdrawer, glass (thermal breakage), gold plating (against 

defective manufacture), airtubes (against warpage) and door handles.

The above will be covered for parts and subsidized labour for the fi rst fi ve years and parts only thereafter with the exception of the fi reboxes (see below).

FPI is not liable for freight or labor on any wood burning appliance replaced in fi eld.

Electrical components such as blowers, switches and thermodisc's are covered for two years parts and one year subsidized labour* from date of purchase.

Repair/replacement parts purchased by the consumer from FPI after the original coverage has expired on the unit will carry a 90 day warranty, valid with a 

receipt only. Any item shown to be defective will be repaired or replaced at our discretion. No labor coverage is included with these parts.

Conditions:

Any part or parts of this unit which in our judgement show evidence of such defects will be repaired or replaced at FPI's option, through an accredited distribu-

tor or agent provided that the defective part be returned to the distributor or agent 

Transportation Prepaid,

 if requested.

It is the general practice of FPI to charge for larger, higher priced replacement parts and issue credit once the replaced component has been returned to FPI 

and evaluated for manufacturer defect.

The authorized selling dealer is responsible for all in-fi eld service work carried out on your Regency product. FPI will not be liable for results or costs of 

workmanship from unauthorized service persons or dealers. 

At all times FPI reserves the right to inspect product in the fi eld which is claimed to be defective.

All claims must be submitted to FPI by authorized selling dealers. It is essential that all submitted claims provide all of the necessary information including 

customer name, purchase date, serial #, type of unit, problem, and part or parts requested, without this information the warranty will be invalid.

Exclusions:

This limited Lifetime Warranty does not extend to or include paint, door or glass gasketing, fi rebrick or trim. It does not cover installation and operational related 

problems such as over-fi ring, use of corrosive driftwood, downdrafts or spillage caused by environmental conditions, nearby trees, buildings, hilltops, mountains, 

inadequate venting or ventilation, excessive offsets, negative air pressures caused by mechanical systems such as furnaces, fans, clothes dryers etc.

At no time will FPI be liable for any consequential damages which exceed the purchase price of the unit. FPI has no obligation to enhance or modify any unit 

once manufactured. ie. as products evolve, fi eld modifi cations or upgrades will not be performed.

FPI will not be liable for travel costs for service work. 

Installation and environmental problems are not the responsibility of the manufacturer and therefore are not covered under the  terms of this warranty 

policy.

Any unit which shows signs of neglect or misuse is not covered under the terms of this warranty policy.

The warranty will not extend to any part which has been tampered with or altered in any way, or in our judgment has been subject  to misuse.

Freight damage to stoves and replacement parts is not covered by warranty and is subject to a claim against the freight carrier by the dealer.

FPI will not be liable for acts of God, or acts of terrorism, which cause malfunction of the appliance.

Performance problems due to operator error will not be covered by this warranty policy.

Products made or provided by other manufacturers and used in conjunction with the operation of this appliance without prior authorization from FPI, may 

nullify your warranty on this product.

* Subsidy according to job scale as predetermined by FPI.

For Model: F1100  F3100  S3100  H2100  I1100  I3100  F2400 

  

     S2400  I2400  Z2510  FP90

Summary of Contents for I1205S

Page 1: ...Canada V4G 1H4 918 998a I1205S Wood Insert 11 24 14 Owners Installation Manual Tested by Installer Please complete the details on the back cover and leave this manual with the homeowner Homeowner Please keep these instructions for future reference www regency fire com ...

Page 2: ...ENCY DEALER in your area Keep those REGENCY FIRES burning SAFETY NOTE If this Insert is not properly installed a house fire may result For your safety follow the installation instructions contact local building or fire officials about restrictions and installation inspection requirements in your area The authority having jurisdiction such as municipal building department fire department fire preve...

Page 3: ...place 10 Stainless steel smoke deflector Installation 11 Faceplate Trim Optional 12 Bottom Faceplate Fan Support Installation 12 Fan Blower 16 Door Handle 17 Firebrick Assembly 17 Draft Control 17 Brick Flue Baffle Secondary Air Tube Installation 17 Screen Door 18 OPERATING INSTRUCTIONS First Fire 18 Fan Operation 19 Ash Disposal 19 Some Safety Guidelines 19 MAINTENANCE Creosote 19 Maintenance Of ...

Page 4: ...ATE WITH FEED DOOR CLOSED OPEN TO FEED FIRE ONLY REPLACE GLASS ONLY WITH CERAMIC GLASS 5MM INSPECT AND CLEAN CHIMNEY FREQUENTLY UNDER CERTAIN CONDITIONS OF USE CREOSOTE BUILDUP MAY OCCUR RAPIDLY DO NOT OVERFIRE IF INSERT GLOWS YOU ARE OVER FIRING MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS MEASURED FROM INSERT BODY INSTALL ONLY ON A NON COMBUSTIBLE HEARTH RAISED F 1 5IN 38MM ABOVE AN ADJACENT COMB...

Page 5: ...I1205 Regency Wood Insert 5 DIMENSIONS WITH STANDARD FLUE ADAPTOR 6 152mm Diameter STANDARD FLUE ADAPTOR 171 932 ...

Page 6: ...14 3 16 360mm 12 3 4 324mm 17 3 4 451mm 22 3 4 578mm 18 3 4 476mm 19 1 2 496mm 22 3 4 578mm 21 3 8 543mm 22 3 4 578mm 21 1 4 540mm 16 7 8 428mm 20 1 8 511mm 6 152mm Diameter OFFSET FLUE ADAPTOR 171 936 12 3 4 from flue centerline to rear of faceplate 16 15 16 430mm ...

Page 7: ...nd using your fireplace insert Install and use only in accordance with manufacturer s installation and operating instructions 2 Check your local building codes Build ing Inspection Department You may require a permit before installing your insert Be aware that local codes and regulations may override some items in the manual WARNING Careless installation is the major cause of safety hazard Check a...

Page 8: ... 84 The proposed alternative is 4 100mm brick with a C factor of 1 25 over 1 8 3mm mineral board with a K factor of 0 29 Step a Use formula above to convert specification to R value R 1 k x T 1 0 84 x 75 0 893 Step b Calculate R of proposed system 4 brick of C 1 25 therefore Rbrick 1 C 1 1 25 0 80 1 8 mineral board of k 0 29 therefore Rmin bd 1 0 29 x 0 125 0 431 Total R Rbrick Rmineral board 0 8 ...

Page 9: ...ar of the unit into the fireplace See diagram 3 Ensure that the unit is centered in the existing fireplace and lined up with the flue adaptor 4 Slide the unit back until the flue adaptor is slightly engaged 5 At this point it is recommended to level the unit and ensure that the leveling bolts rest onthesurfaceofthefireplace Thiswillkeep the adaptor from binding as the unit is slid into position 6 ...

Page 10: ...insert must be installed as per the require ments of your local inspection authority Three methods of flue connection are acceptable in most areas these include 1 Positive flue connection where a large blocking plate and a short connector pipe is used 2 Direct flue connection where a smaller blocking plate and a connector pipe to the first flue liner tile is used 3 Full flue liner where a stainles...

Page 11: ...ff both bolts and slide defector upward and out Install new defector and hand tighten bolts Ensure positive location of the defector prior to hand tightening WARNING Operation of the unit with out proper installation of smoke deflector will void warranty Smoke deflector is installed through the door opening in location shown in diagram Smoke deflector Ensure defector is seated so bolts are situate...

Page 12: ...NSTALLATION FACEPLATE TRIM OPTIONAL BOTTOM FACEPLATE FAN SUPPORT INSTALLATION 918 676c 01 28 08 1 I1200 FACEPLATE TRIM FAN OPTIONAL BOTTOM FACEPLATE FAN SUPPORT INSTALLATION Regular Faceplate Dimensions Oversize Faceplate Dimensions ...

Page 13: ...iagram 2 Rear View 4 Position the assembled faceplate side and top to the insert Ensure to align the draft rod into the opening of the faceplate as well as the side faceplate slots with the bolts in the mounting brackets as shown in Diagram 3 5 Measure the height between the hearth and the bottom of the side faceplate 6 Cut the bottom faceplate to the measured height using a metal cutting blade 7 ...

Page 14: ...Diagram 5 Diagram 6 Shown with Optional Bottom Faceplate Regular Oversize Faceplate Trim Installation Black Trim included with Regular Oversize Faceplate or Optional Brass Trim Fan Installation 12 Install the fan assembly to ash lip of insert as shown in Diagram 7 Diagram 7 13 To install the optional fan support measure the distance between the hearth and the bottom surface of the fan housing as s...

Page 15: ...ly using 4 self tapping screws See Diagram 9 Diagram 9 Rear Bottom View 18 Secure the bottom faceplate to the 3 sided faceplate using the 4 supplied bolts washers 19 Discard both side trims that were included with the regular oversize faceplate and replace with the new extended trims supplied with the fan support bottom faceplate Cut to desired length 20 Fit the trim assembly over the faceplate as...

Page 16: ...el all wires prior to disconnection when servic ing controls Wiring errors can cause improper and dangerous operation WARNING Electrical Grounding Instructions This appliance is equipped with a three pronged grounding plug for yourprotectionagainstshockhazard and should be plugged directly into a properly grounded three prong receptacle Do not cut or remove the grounding prong from this plug with ...

Page 17: ...your 1 If the two air tubes are installed continue on to Step 2 if not follow the instructions below Installtheairtubeintotheholesinthe side channels The notch goes on the right hand side with the air holes facing toward the door Slide the tube into the left hand side asfaraspossibleandthenbringitback into the hole on the right hand side until it locks into position If the tube will not slide in e...

Page 18: ...ay be more difficult to start the fire As you dry out your fire brick and your masonry flue if applicable your draft will increase 10 Forthoseunitsinstalledathigherelevations or into sub standard masonry fireplaces drafting problems may occur Consult an experienced dealer or mason on methods of increasing your draft 11 Some cracking and popping noises may be experienced during the heating up proce...

Page 19: ... To manually operate the fan system push the first switch to Man and second switch to either high or Low This will bypass the sensing deviceandallowfullcontrolofthefan Switching from Auto to Manual or High to Low may be done at any time ASH DISPOSAL During constant use ashes should be removed every few days Please take care to prevent the build up of ash around the start up air housing located ins...

Page 20: ...moval of the spacer washer shown in the diagram below will allow the latch to be moved closer to the door frame causing a tighter seal Removeandreplacethenuts washerasshown GLASS CLEANING Do not attempt to clean the glass when it is hot allow the glass to cool before cleaning Do not use abrasive cleaners to clean the glass Your local retailer can supply you with special glass cleaner if plain wate...

Page 21: ...sket Kit 17 846 918 Hinge Caps 2 set Gold 19 948 101 Spring Handle Large Gold 20 948 102 Spring Handle Small Gold 170 915 Fan Blower Assembly 24 910 157 P Blower Fan Motor 25 910 678 Power Cord 120 Volts 27 910 142 Fan Thermodisc 28 910 140 Fan Speed Switch HI OFF LOW 3 way 29 910 138 Switch Auto Manual 2 way 30 Grommet Strain Relief 35 074 954 Air Tube 1 Qty 1 36 033 953 Air Tube 3 4 Qty 1 38 073...

Page 22: ...aceplate Trim Set Oversize Black 171 926 Trim Set Oversize Brass 171 572 Trim Set Oversize Black 171 928 Bottom Piece and Fan Support Regular 171 930 Bottom Piece and Fan Support Oversize 60 Faceplate Right Side Regular Oversize 61 Faceplate Left Side Regular Oversize 62 Faceplate Top Regular Oversize 64 Bottom 1 Piece Faceplate 65 Fan Support Not available as a replacement part ...

Page 23: ... Description 170 960 Complete Brick Set 70 Brick Regular Full Size 1 1 4 x 4 1 2 x 9 76 Brick Partial 1 1 4 x 2 x 9 81 Brick Partial 1 1 4 x 1 1 4 x 9 84 Brick Partial 1 1 4 x 4 1 2 x 8 85 Brick Partial 1 1 4 x 4 1 4 x 8 Not available as a replacement part ...

Page 24: ...24 I1205 Regency Wood Insert NOTES ...

Page 25: ...I1205 Regency Wood Insert 25 NOTES ...

Page 26: ...26 I1205 Regency Wood Insert NOTES ...

Page 27: ...nauthorized service persons or dealers At all times FPI reserves the right to inspect product in the field which is claimed to be defective All claims must be submitted to FPI by authorized selling dealers It is essential that all submitted claims provide all of the necessary information including customer name purchase date serial type of unit problem and part or parts requested without this info...

Page 28: ...______________________________________________________ Printed in Canada Regency fireplace products are designed with reliability and simplicity in mind In addition our internal QualityAssurance Teamcarefullyinspectseachunitthor oughly before it leaves our door FireplaceProductsInternational Ltd is pleased to extend this Limited Lifetime Warranty to the original purchaser of a Regency Product See ...

Page 29: ...ODELS I1205S WOOD Fireplace Insert 12 17 14 MANUEL D INSTALLATION ET D UTILISATION Installateur Remplissez la fiche de la couverture arrière et laissez ce manuel au propriétaire du foyer Propriétaire du foyer Conservez ces instructions pour référence ultérieure www regency fire com Tested by ...

Page 30: ...au chaud avec nos POÊLES À BOIS Hampton NOTE DE SÉCURITÉ Si ce poêle à bois n est pas installé correctement cela peut causer un incendie Pour votre sécurité suivez les instructions d installation contactez les agents locaux du bâtiment ou du service incendie ou l autorité compétente ayant juridiction quant aux restrictions et exigences d inspection des installations de votre région L authorité aya...

Page 31: ...Your Insert 9 Installation Into a Masonry Fireplace 10 Installation Into a Factory Built Fireplace 10 Stainless steel smoke deflector Installation 11 Faceplate Trim Optional 12 Bottom Faceplate Fan Support Installation 12 Fan Blower 16 Door Handle 17 Firebrick Assembly 17 Draft Control 17 Brick Flue Baffle Secondary Air Tube Installation 17 Screen Door 18 OPERATING INSTRUCTIONS First Fire 18 Fan O...

Page 32: ... FIRE BUILD WOOD FIRE DIRECTLY ON HEARTH OPERATE WITH FEED DOOR CLOSED OPEN TO FEED FIRE ONLY REPLACE GLASS ONLY WITH CERAMIC GLASS 5MM INSPECT AND CLEAN CHIMNEY FREQUENTLY UNDER CERTAIN CONDITIONS OF USE CREOSOTE BUILDUP MAY OCCUR RAPIDLY DO NOT OVERFIRE IF INSERT GLOWS YOU ARE OVER FIRING MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS MEASURED FROM INSERT BODY INSTALL ONLY ON A NON COMBUSTIBLE HEAR...

Page 33: ...Regency I1205M 5 UNIT DIMENSIONS WITH STANDARD FLUE ADAPTOR 6 152mm Diameter STANDARD FLUE ADAPTOR 171 932 ...

Page 34: ...4 324mm 17 3 4 451mm 22 3 4 578mm 18 3 4 476mm 19 1 2 496mm 22 3 4 578mm 21 3 8 543mm 22 3 4 578mm 21 1 4 540mm 16 7 8 428mm 20 1 8 511mm 6 152mm Diameter OFFSET FLUE ADAPTOR 171 936 12 3 4 from flue centerline to rear of faceplate 16 15 16 430mm UNIT DIMENSIONS ...

Page 35: ...Vérifiez votre code de construction local service d inspection municipal Vous aurez peut être besoin d un permis Soyez conscient que certaines règles ou codes locaux peuvent avoir préséance sur certains items de ce manuel AVERTISSEMENT Lesinstallationsdemau vaise qualité sont dangeureuses Vérifiez bien tous les codes du bâtiment de votre régionainsiquelesnormesdesécuritéavant d installer votre app...

Page 36: ... côté Supérieur Latéral Min Min latérale min d Âtre d Âtre de l âtre A B C D E F G Medium Flush Insert I1205 15 381mm 20 508mm 14 356mm 7 357 187mm 16 406mm 1 5 38mm 8 200mm L extensiondel âtre E etl extensionlatérale de l âtre G sont mesurées à partir de la portedechargementjusqu aucôtédel âtre CHOISIR LE BON REVÊTEMENT DE PROTECTION DE SOL Le matériau recommandé pour protéger le sol devrait mesu...

Page 37: ...ouleveretdéposerl arrière de l appareil dans l âtre schéma 3 Centrer l appareil et l aligner avec l adaptateur de conduit 4 Glisserl appareilàl intérieurdufoyerjusqu à ce que l adaptateur soit partiellement en gagé 5 Mettre l appareil au niveau et s assurer que les vis réglables reposent bien sur le plancher du foyer pour éviter de coincer l adaptateur en glissant l appareil en place 6 Passer la t...

Page 38: ...omplet pour une sécurité maximale et un rendement optimal Votre détaillant devrait êtreenmesuredevousaideràchoisirlesystème qui vous convient le mieux L utilisation d une des méthodes de raccorde ment inscrites sur cette page augmente non seulement la sécurité de votre encastrable en dirigeant les gaz d évacuation vers le haut de la cheminée mais augmente aussi la performance de l appareil tout en...

Page 39: ...resserrer s assurer que les boulons qui maintiennent le déflecteur sont bien logés dans le haut du trou piriforme Pour remplacer le déflecteur dévisser les deux boulons et le glisser vers le haut pour le dégager Installer un nouveau déflecteur vérifier sa position et resserrer les boulons à la main AVERTISSEMENT Un déflecteur mal installé annulera la garantie de l appareil Smoke deflector is insta...

Page 40: ...Regency I1205M 12 INSTALLATION Faceplate Assembly FACEPLATE TRIM OPTIONAL BOTTOM FACEPLATE FAN SUPPORT INSTALLATION ...

Page 41: ...agram 2 Rear View 4 Poser la façade assemblée sur l appareil en veillant à passer la tige du régulateur de tirage dans l ouverture prévue à cet effet Placer également les crans de la façade vis à vis des boulons des ferrures de montage schéma 3 5 Mesurer la distance entre l âtre et le bas de la façade 6 Àl aided unescieàmétaux couperlagarnitureinférieureàlahauteur voulue 7 Enlever la façade et y f...

Page 42: ...ure noire fournie avec façade standard ou grand format garniture en laiton vendue séparément Installation du ventilateur 12 Le ventilateur s installe sous le garde cendres schéma 7 Diagram 7 13 Pour installer un support de ventilateur optionnel mesurer la distance entre l âtre et le dessous du boîtier du ventilateur schéma 8 14 À l aide d une scie à métaux couper la garniture inférieure et le sup ...

Page 43: ... Diagram 9 Rear Bottom View 19 Mettre de côté les deux garnitures de finition latérales pour façade standard ou grand format et les remplacer par les garnitures plus longues fournies avec la garniture inférieure et le support de venti lateur Les couper à la longueur voulue 20 Glisser la garniture sur la façade schéma 6 21 À l aide des vis taraudeuses fournies percer deux trous de 5 32 po de diamèt...

Page 44: ...ucune surface chaude Attendre au moins 30 minutes après l allumageouattendrequel appareilatteigne sa température de fonctionnement avant de mettre le ventilateur en marche Installer Please record unit serial number here before installing blower Serial No ______________________________ ATTENTION Marquer tous les fils avant le débranchage en entretenant des commandes Les erreurs de câblage peuvent c...

Page 45: ...mission sur le dessus de la chambre de combustion et juste en dessous du déflecteur 1 Si les deux tubes d air sont déjà instal lés passer à l étape 2 sinon suivre les présentes directives Insérer chacun des tubes d air dans les buses latérales Placer l encoche à droite et en veillant à ce que les orifices soient orientés vers la porte Insérer l extrémité d un tube dans la buse de gauche le plus pr...

Page 46: ...ertainsbruitsdecraquementetdeclaque ment sont possibles lors des cycles de préchauffage Ces bruits seront minimes lorsquelefoyerauraatteintsatempérature 12 Avant d ouvrir la porte pour remettre du bois ouvrez complètement le tirage durant environ 10 à 15 secondes jusqu à ce que le feu soit rétabli pour minimiser la fumée 13 Tous les appareils de combustion consom ment de l oxygène durant l utilisa...

Page 47: ...LLOW ASHES TO BUILD UP TO THE LOADING DOORS Onlyremoveasheswhenthefirehasdieddown Even then expect to find a few hot embers Always leave 1 to 2 inches of ash in the bottom of the firebox This helps in easier starting and a more uniform burn of your fire Ashesshouldbeplacedinametalcontainerwith a tight fitting lid The closed container of ashes should be placed on a noncombustible floor or on the gr...

Page 48: ...e et en améliorer l étanchéité retirer la rondelle d espacement tel qu illustré ci dessous Retirer et replacer les écrous les boulons et les rondelles d espacement tel qu illustré ENTRETIEN DE LA VITRE Votre poêle à bois Regency est fourni avec une vitre en Neoceram verre vitrocéramique de 5 mm Pièce no 846 302 résistant aux hautes températuresproduitesparcepoêle Sivousbri sez la vitre par impact ...

Page 49: ...Kit 17 846 918 Hinge Caps 2 set Gold 19 948 101 Spring Handle Large Gold 20 948 102 Spring Handle Small Gold 170 915 Fan Blower Assembly 24 910 157 P Blower Fan Motor 25 910 678 Power Cord 120 Volts 27 910 142 Fan Thermodisc 28 910 140 Fan Speed Switch HI OFF LOW 3 way 29 910 138 Switch Auto Manual 2 way 30 Grommet Strain Relief 35 074 954 Air Tube 1 Qty 1 36 033 953 Air Tube 3 4 Qty 1 38 073 955 ...

Page 50: ...ate Trim Set Oversize Black 171 926 Trim Set Oversize Brass 171 572 Trim Set Oversize Black 171 928 Bottom Piece and Fan Support Regular 171 930 Bottom Piece and Fan Support Oversize 60 Faceplate Right Side Regular Oversize 61 Faceplate Left Side Regular Oversize 62 Faceplate Top Regular Oversize 64 Bottom 1 Piece Faceplate 65 Fan Support Not available as a replacement part ...

Page 51: ...iption 170 960 Complete Brick Set 70 Brick Regular Full Size 1 1 4 x 4 1 2 x 9 76 Brick Partial 1 1 4 x 2 x 9 81 Brick Partial 1 1 4 x 1 1 4 x 9 84 Brick Partial 1 1 4 x 4 1 2 x 8 85 Brick Partial 1 1 4 x 4 1 4 x 8 Not available as a replacement part ...

Page 52: ...orized service persons or dealers At all times FPI reserves the right to inspect product in the field which is claimed to be defective All claims must be submitted to FPI by authorized selling dealers It is essential that all submitted claims provide all of the necessary information including customer name purchase date serial type of unit problem and part or parts requested without this informati...

Page 53: ..._________________________________________________________ Printed in Canada Regency fireplace products are designed with reliability and simplicity in mind In addition ourinternalQualityAssurance Team carefully inspects each unit thoroughlybeforeitleavesourdoor FireplaceProductsInternation al Ltd is pleased to extend this Limited Lifetime Warranty to the original purchaser of a Regency Product See...

Reviews: