L390E / HZI390E Direct Vent Gas Insert
21
INSTALLATION
WIRING DIAGRAM
This heater does not require a 120V A.C. supply for operation. In case of a power failure, the burner switch and the optional remote control/thermostat will
continue to operate. However, a 120V A.C. power supply is needed for the fan/blower operation.
(Do not cut the ground terminal off under any circumstances.)
Proflame System
Configuration
886 GTMF
Wire Diagram
0.880.001
Profl ame System
Confi guration
885 ON/OFF
Illustrated wire diagram
0.584.907
PROFLAME REMOTE SYSTEM GTM (L390E / HZI390E)
SureFire™ Switch
CAUTION: Label all wires prior to disconnection
when servicing controls. Wiring errors can
cause improper and dangerous operation.
Caution: Ensure that the wires do not touch any
hot surfaces and are away from sharp edges.
GTM REMOTE SYSTEM - IMPORTANT:
The AA batteries in the receiver operate the unit. If the batteries become weak, they will need
to be replaced with quality AA alkaline batteries. The unit will not operate without AA batteries.
Thermostat
(Optional)
See optional wall thermostat
installation in this manual.