12
|
Regency Horizon® HZO60 Gas Fireplace
|
12
installation
Steel studs
A
B
C
D
Metal Stud
on edge
Note:
All other framing may
be of wood construction.
Note:
Consideration should be given to weather / elements
when choosing framing materials (ie. treated lumber, steel stud).
DETAIL K
SCALE 1 : 5
I
H
J1
J2
K
Framing
Dimensions
Description
HZO60 See Through
A
Framing Height
40-1/4" (1022mm)
B
Framing Width
69" (1753mm)
C
Minimum framing depth
18-1/2"" (470mm)
**minus 2X the finished material thickness
D
Minimum Height to Combustibles (Chase Enclosure)
43-3/4" (1111mm)
H
Gas Connection Opening Height
2" (51mm)
I
Gas Connection Height
3-11/16 " (93mm)
J1
Gas Connection Inset
6-3/16" (157mm)
J2
Gas Connection Inset
6-3/16" (157mm)
K
Gas Connection Opening Width
3" (76mm)
**Finished material thickness includes: non combustible material, tile slate, etc.
(example framing = 18-1/2" - if 2" thick finishing material is used (on both sides)=14-1/2" framing depth.
FRAMING DIMENSIONS SEE THROUGH
Important Note:
Two (2) ventilation grills are highly recommended for all enclosures.
This is to alleviate moisture and allow for air to circulate. Minimum recommended size: 20" sq. (508 mm
²) ea.