12
Regency FG39-1 FireGenie Freestanding Gas Stove
INSTALLATION
d) Cut the 2 ft. (.6m) section of rigid pipe
to length. Ensure that the pipe length
when cut will seat onto both the starter
collar and the 90
o
elbow.
Crimped
section of rigid pipe seats into the
90
o
elbow. Only cut the uncrimped
side of pipe.
Dismantle all pipe sections including fl ue
terminal.
3) Attach the 4" (102mm) dia. fl ex liner to the
fl ue terminal ensuring that the fl ex overlaps
the collar of the fl ue terminal by a minimum
of 1-3/8"(35mm). Use Mill-Pac to seal and
secure with 3 of the #8 x 1/2" (13mm) screws
(stainless steel).
4) Attach the 2 ft. (.6m)pipe section to the fl ue
terminal using Mill-Pac and/or high tempera-
ture silicone and attach with 3 of the #8 x
1/2" (13mm) screws (stainless steel).
6) A bead of non-hardening mastic should be
run around both the termination and vinyl
siding standoff to prevent water from entering
and to make a tight seal between the cap
and the standoff.
7) Stretch the 4" (102mm) dia. fl ex liner out
fully and get a trial fi t of the liner onto the
4" (102mm) dia. starter collar.
8) Cut the 4" (102mm) dia. fl ex liner to the
desired size.
Hint: leave an extra 12" to 16" (305mm to
406mm) of length, this will make the fi nal
assembly easier to work with.
9) Secure the 4" (102mm) dia. fl ex liner to the 4"
(102mm) adapter with Mill-Pac and 3 of the
#8 x 1/2" (13mm) screws (stainless steel).
10) Slide the Decorative Wall Cover over the
pipe sections.
11) Slide the 90
o
elbow (crimp end up) and the
2 ft. (.6m) pipe section (crimp end up) over
the 4" dia. fl ex liner.
12) Slide the trim collar over the pipe section to
cover the joint.
13) Install the spring spacers onto the pipe
sections.
14) Secure the 4" (102mm) dia. fl ex liner with
adapter onto the stove collar. Put a bead of
Mill-Pac around the appliance adapter and
secure with 3 screws (#8 x 1/2" / 13mm,
stainless steel).
15) Attach the pipe section onto the starter
collar by sealing with Mill-Pac and/or high
temperature silicone and securing with 3 of
the #8 x 1/2" (13mm) (black) screws. Pipe
seams should be facing the wall.
16) Attach the 90
o
elbow onto the pipe section by
sealing with Mill-Pac and/or high tempera-
ture silicone and securing with 3 of the #8
x 1/2" (13mm) screws (black).
17) Slide the 2 ft. (.6m) pipe section onto the 90
o
elbow. The fl ex may have to be compressed
back in order for the pipe to properly mate
to the elbow. Seal with Mill-Pac and/or high
temperature silicone and secure with 3 of
the #8 x 1/2" (13mm) screws (black). Pipe
seams facing down.
18) Install the trim collar over the starter collar
and secure with a #8 x 1/2" (13mm) screw
(black).
If the pipe needs to be touched up, use only
Stove Brite High Temperature Metallic Black
Stove Paint.
NOTE: All inner joints must be sealed with
Mill-Pac.
All outer joints may be sealed with
high temperature silicone.
Note: The pipe seam should be facing
down.
Note: To make the installa-
tion more aestheti-
cally pleasing, we
recommend framing
out a square that the
cap can be mounted
on.
Note: If installing termination on a siding
covered wall, a vinyl siding standoff or
furring strips must be used to ensure
that the termination is not recessed
into the siding. For vinyl siding stand-
off installation refer to the Dura-Flue
Termination instructions.
5) Slide the partially connected pipe and fl ue
terminal assembly through the wall (from
the exterior into the interior) and secure the
cap to the exterior wall with 4 of the supplied
screws (#8 x 1-1/2" (38mm) drill point, stain-
less steel).
Note: The four screws provided for the
fl ue cap should be replaced with ap-
propriate fasteners for stucco, brick,
concrete, or other types of sidings.
Hint:
Apply
the
sealant (Mill-
Pac and/or high
t e m p e r a t u r e
silicone) to the
outer pipe be-
fore connecting
the inner pipe.
#8 x ½" (13mm) Self Tapping, Stainless Steel
#8 x ½"
Self Tapping, Black
(13mm)
#8 x 1½" (38mm) Drill Point, Stainless Steel