Regency

®

 F39 Room Sealed Freestanding Gas Stove

Diagram 11: The upper half of the fl ashing is 

installed under the roofi ng material and not 

nailed down until the chimney is installed. This 

allows for small adjustments.

4)

  Assemble the desired lengths of black pipe 

and  elbows necessary to reach from the 
appliance adaptor up though the Round 
Support Box. Insure that all pipes and elbow 
connections are in the fully twist-locked 
position and sealed.

5)

  Cut a hole in the roof centred on the small 

drilled hole placed in the roof in Step 2. The 
hole should be of suffi cient size to meet 
the minimum requirements for clearance 
to combustibles of 1-1/4". Slip the fl ashing 
under the shingles (shingles should overlap 
half the fl ashing) as per diagram 11.

Diagram 12

7)

  Ensure fl ue is vertical and secure the base 

of the fl ashing to the roof with roofi ng rails, 
slide storm collar over the pipe section and 
seal with a mastic.

8)

  Install the vertical termination cap by twist 

locking it.

 Notes:

 a)

  For multistorey vertical installations, a 

Ceiling Fire stop (Part # 963) is required 
at the second fl oor, and any subsequent 
fl oor. Diagram 13.  The opening should 
be framed to 10 " x 10" inside dimen-

6)

  Continue to assemble pipe lengths.

Note:  If an offset is necessary in the attic to 

avoid obstructions, it is important to 
support the fl ue pipe every 3 feet, to 
avoid excessive stress on the elbows, 
and possible separation.  Wall straps 
are available for this purpose.  See 
diagram 7. 

 
 

Galvanized pipe and elbows may be utilized 
in the attic as well as above the roofl ine.  
The galvanized fi nish is desirable above the 
roofl ine due to its higher corrosion resist-
ance.

 

Continue to add pipe sections through the 
fl ashing until the height of the fl ue cap meets 
the minimum height requirements specifi ed 
in diagram 12 or local codes.  Note that for 
steep roof pitches, the vertical height must 
be increased.  A poor draft, or down drafting 
can result from high wind conditions near 
big trees or adjoining roof lines, in these 
cases, increasing the fl ue height may solve 
the problem.

    Roof Pitch                   Minimum Flue Height

                                           Feet         Meters

fl at to 7/12 

      

0.61

over 7/12 to 8/12 

0.61

over 8/12 to 9/12 

0.61

over 9/12 to 10/12 

2.5 

0.76

over 10/12 to 11/12 

3.25 

0.99

over 11/12 to 12/12 

1.22

over 12/12 to 14/12 

1.52

over 14/12 to 16/12 

1.83

over 16/12 to 18/12 

2.13

over 18/12 to 20/12 

7.5 

2.29

Diagram 10

Diagram 9

Diagram 8

Diagram 7

Diagram 6

DURA-FLUE VERTICAL 

TERMINATION

1)

  Maintain the 1-1/4" clearances 

(air spaces) to combustibles 
when passing through ceil-
ings, walls, roofs, enclo-
sures, attic rafter, or other 
nearby combustible surfaces. 
Do not pack air spaces with 
insulation. Check page 9 for 
the maximum vertical rise 
of the fl uing system and the 
maximum horizontal offset 
limitations.

3)

  To install the Round Support Box/Wall Thim-

ble in a fl at ceiling, cut a 10 inch square hole 
in the ceiling centred on the hole drilled in 
Step 2. Frame the hole as shown in diagram 
10.

INSTALLATION

8)

  Slide the decorative wall thimble up to the 

wall surface being careful not to scratch 
the paint and attach with screws provided. 
Apply decorative brass or chrome trim if 
desired. See diagram  7.

2)

  Set the gas appliance in 

its desired location. Drop a 
plumb bob down from the 
ceiling to the position of the 
appliance fl ue exit, and 
mark the location where 
the fl ue will penetrate the 
ceiling. Drill a small hole 
at his point. Next, drop a 
plumb bob from the roof to 
the hole previously drilled 
in the ceiling, and mark the 

spot where the fl ue will penetrate the roof. 
Determine if ceiling joists, roof rafters or 
other framing will obstruct the fl uing system. 
You may wish to relocate the appliance or 
to offset, as shown in diagram 9 to avoid 
cutting load bearing members.

Summary of Contents for F39-LPG

Page 1: ...n consult an authorized installer service agency or the gas supplier FOR YOUR SAFETY Do not store or use gasoline or other flam mable vapours and liquids in the vicinity of this or any other appliance Installation and service must be performed by an authorized installer service agency or the gas supplier PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE Owners Installation Manual LISTINGS AND COD...

Page 2: ... you with all the warmth and charm of a woodstove at the flick of a switch The models F39 NG and F39 LPG of this series has been approved by Warnock Hersey for both safety and efficiency As it also bears our own mark it promises to provide you with economy comfort and security for many trouble free years to follow Please take a moment now to acquaint yourself with these instructions and the many fea...

Page 3: ...ance 26 Removing Valve 27 PARTS LIST F39 Main Assembly 28 F39 Burner Log Assembly 29 F39 Door Assemblies 30 WARRANTY Warranty 31 Unit Specifications 2 SAFETY LABEL Safety Label 4 INSTALLATION Important 5 Specifications 5 Before You Start 5 General Safety Information 5 Installation Checklist 6 Exterior Flue Termination Locations 8 Fluing Arrangements 9 DV Stove Horizontal Flue Kit 10 DV Stove Horizon...

Page 4: ...SealedFreestandingGas Stove We have printed a copy of the contents here for your review The data plat is located on the inside of the drop down pedestal door NOTE Regency units are constantly being improved Check the label on the unit and if there is a difference the label on the unit is the correct one Australia Only ...

Page 5: ...the floor 4 This appliance is Listed for bedroom instal lations when used with a Listed Millivolt Thermostat Some areas may have further requirements check local codes before installation 5 This appliance is Listed for Alcove installa tions maintain minimum Alcove clearances asfollows minimumwidthof48 1219mm a maximum depth of 36 914mm and minimum ceiling height of 64 1626mm 6 We recommend that you...

Page 6: ...0 Be aware of electrical wiring locations in walls and ceilings when cutting holes for termination 11 Under no circumstances should this ap pliance be modified Parts that have to be removed for servicing should be replaced prior to operating this appliance 12 Installation and any repairs to this appliance should be done by an authorised service person Anauthorisedservicepersonshould be called to in...

Page 7: ...Termination Location section INSTALLATION PRECAUTIONS These fluing systems are engineered products that have been designed and tested for use with the F39 NG and F39 LPG The warranty will be voided and serious fire health or other safety hazards may result from any of the fol lowing actions 1 Installation of any damaged Room Sealed component 2 Unauthorized modification of the Room Sealed System 3 Ins...

Page 8: ...anical air inlet or any other opening into a building with the exception of sub floor ventilation see also Note I Appliances up to 150 MJ h input 500 Appliances over 150 MJ h input 1500 k Vertically below an openable window door or non mechanical air inlet or any other opening into a building with the exception of sub floor ventilation see also Note I see table below Clearance k in mm Space Heaters ...

Page 9: ...ns for All Fluing Systems Theshadedareasinthediagrambelowshowallallowablecombina tions of vertical runs with horizontal terminations Maximum one 90O elbow two 45o elbows equal one 90o elbow LPG and NG Residential Manufactured and Mobile Homes Installations The fluing arrangements diagrammed below have a min of 75 flue loss efficiencywithFanOff asrequiredformanufacturedhomes Actual efficiency may be as...

Page 10: ...nto position from theexterior Thelargerdiameterend of the adjustable pipe goes to the flue terminal c Install the 90o elbow onto the adjust able pipe to determine the vertical centerline of the starter collar on the unit Note if the centerline cannot be met the adjustable sections will have to be cut d Cut the 2 ft section of rigid pipe to length Ensure that the pipe length DV STOVE HORIZONTAL FLUE...

Page 11: ...y sealing with Mill Pac and or high temperature silicone and securing with 3 of the 8 x 1 2 black screws Pipe seams should be facing the wall 16 Attachthe90o elbowontothepipesectionby sealing with Mill Pac and or high tempera ture silicone and securing with 3 of the 8 x 1 2 screws black 17 Slide the 2 ft pipe section onto the 90o el bow The flex may have to be compressed back in order for the pipe ...

Page 12: ...ed the maximum number of elbows One 90o for horizontal terminations and two 45o for vertical termination DURA FLUE FLUING COMPONENTS You will require the following components with your new Regency Room Sealed Freestand ing Gas Stove Please review your product to make sure you have everything you need In the eflue that you are missing any part contact your dealer Note These are the minimum pieces re...

Page 13: ...ard This could cause high temperatures and may present the possibility of a fire INSTALLATION DURA FLUE HORIZONTAL INSTALLATIONS 1 Set the unit in its desired location Check to determine if wall studs or roof rafters are in the way when the fluing system is attached If this is the case you may want to adjust the location of the unit 2 RoomSealedpipeandfittingsaredesigned with special twist lock conne...

Page 14: ...in diagram 12 or local codes Note that for steep roof pitches the vertical height must be increased Apoor draft or down drafting can result from high wind conditions near big trees or adjoining roof lines in these cases increasing the flue height may solve the problem Roof Pitch Minimum Flue Height Feet Meters flat to 7 12 2 0 61 over 7 12 to 8 12 2 0 61 over 8 12 to 9 12 2 0 61 over 9 12 to 10 12 2...

Page 15: ...lows Slope X 0 12 2 12 4 2 12 7 12 5 1 2 7 12 12 12 6 3 4 12 12 24 12 7 1 2 24 12 12 1 2 1 Situate the chimney in a convenient loca tion as near as possible to the appliance outlet Cut and frame a hole in the roof for the support The sides of this hole must be vertical with 1 1 4 clearance 2 Place the support in the opening Lower it to the correct height as determined by the table and diagram belo...

Page 16: ...at screwdriver 3 Attach manometer to IN and or OUT pressure tap s using a 5 16 ID hose 4 Light the pilot and turn the valve to ON position Read manometer 5 The pressure check should be carried out with the unit burning and the setting should be within the limits specified on the safety label 6 When finished reading manometer turn off the gas valve disconnect the hose and tighten the screw clockwise ...

Page 17: ...i low knob Fig 1 Fig 2 14 Flip the screw Fig 3 Fig 4 Fig 3 15 Using the Allen wrench as shown in Fig 4 rotate the screw clock wise until snug do not overtighten 12 Insert a 5 32 or 4mm Allen wrench into the hexagonal key way of thescrew Fig 2 rotate itcounter clockwiseuntil it is free and extract it 13 Check that the screw is clean and if necessary remove dirt Conversion Kit Contains Qty Part Desc...

Page 18: ... Description 1 904 390 Burner Orifice 52 LPG 1 918 034 Decal Converted to 30 000 Btu 1 918 033 Instruction Sheet Additional Piece pkg with unit 1 Log Bracket Restrictor 1 Shut off the gas supply 2 Open the front door Carefully remove the logs and lava rock 3 Remove burner See diagram below Burner Orifice 4 Unscrew the 2 Rear Log Pins and move tothefrontholeposi tion 5 Remove Rear Log Bracketandslide...

Page 19: ... Pin D 02 46 B 02 56 A 02 65 7 Place the Left Top Log D 02 46 on the pin on Log B 02 56 and on top of the cutout on Log A 02 65 E 02 45 C 02 44 8 Place Front Right Log E 02 45 on the two pins as shown 9 Place the lava rock in the area between the left and right logs leaving a space in the middle for log F 02 47 Cutout Notch F 02 47 E 02 45 A 02 65 10 Place the notch in Center Log F 02 47 over Log ...

Page 20: ...per setting If they are too hard or too easy to close you may want to adjust them by loosening the latch catch See diagram 3 Diagram 2 Diagram 3 5 Remove the blue plastic protective coating from the glass 6 Test the seal around the door by placing a piece of paper between the unit and the door close the door and try to pull the paper out If it slips out easily then the door is not properlysealed T...

Page 21: ...pped with a three pronged grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle Do not cut or remove the grounding prong from This heater does not require a 240VA C supply forthegascontroltooperate A240VA C power supply is needed for the fan blower operation INSTALLATION Caution Ensure that the wires do not touch any ...

Page 22: ...lass front as part of the curing process The glass should be cleaned or the film will bake on and become very difficult to remove Use a non abrasive cleaner and NEVER clean the glass while it is hot 4 Turn the PILOT knob counterclockwise to pilot and align it with the arrow as shown in diagram above 5 Push in PILOT knob all the way in and hold ImmediatelypushIGNITORbuttonuntilpilot lights Continue t...

Page 23: ...t call STOP Read the safety information above on this label 1 Push in gas control knob slightly and turn clockwise to OFF Knob cannot be turned from PILOT to OFF unless knob is pushed in slightly Do not force 2 Wait five 5 minutes to clear out any gas If you then smell gas STOP follow B in the safety information above on this label If you don t smell gas go to the next step 3 Turn knob on gas cont...

Page 24: ...ttern will have small probably yellow flames not coming into proper contact with the rear of the burner or thermopile WARNING CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATURE AND SHOULD STAY AWAY TO AVOID BURNS OR CLOTHING IGNITION YOUNG CHILDREN SHOULD BE CAREFULLYSUPERVISEDWHEN THEY ARE IN THE SAME ROOM AS THE APPLIANCE 7 Each time the appliance is lit it may cause...

Page 25: ... of the left side retainer 7 Put gasket glue on the retainers but do not put glue on the screws Replace the door gasket the two ends butt tight together on the bottom edge of the door 8 Replace door on the stove and check the seal LOG REPLACEMENT The unit should never be used with broken logs Turn off the gas valve and allow the unit to cool before opening door to carefully remove the logs The pil...

Page 26: ...he following procedure a tighten top bottom outside corner nuts 2 b tighten inside nuts 3 c tighten top bottom inside corners 2 8 Tighten the 10 nuts on center glass re tainer 9 Repeat step 7 for other side panel 10 Replace new gasket by gluing it in place 11 Install door onto stove and check the seal To remove F39 fan 1 Unplug or disconnect power source to stove 2 Remove all logs and the rear log...

Page 27: ... control panel is off or you canaccessitthroughtherearpedestalcover plate 6 Carefully remove the logs and lava rock 7 Remove burner If your valve requires maintenance or replace ment use the following instructions Note Always close off the gas supply before removing the valve 1 Open front pedestal door You may want to put a soft cloth on the base of the unit so that when the pedestal door is open ...

Page 28: ...0 Volt 12 910 714 Power Cord 240 Volt 15 560 525 Pedestal Assembly 16 730 039 Pedestal Door 17 904 257 Pedestal Door Magnet 18 560 025 Pedestal Back 19 730 530 Side Panel Door Assy Right Side 20 730 525 Side Panel Door Assy Left Side 21 560 031 Side Panel Door Hinge 23 904 258 Side Panel Door Magnet 24 948 255 Door Latch 25 Flex Pipe 3 ID 26 Clamp for Flex Pipe 27 910 233 Fan Auto On Off Thermodis...

Page 29: ...910 038 Pilot Assy S I T 3 Flame NG 910 039 Pilot Assy S I T 3 Flame LPG 67 Pilot Holder 68 W840470 Pilot Assembly Gasket 71 730 528 Log Stand 904 641 Pilot Orifice 50 NG 75 730 935 Log Set 78 730 550 Burner Assembly 82 630 009 Gasket Burner Tray Air Passage 83 630 008 Gasket Burner Tray Firebox 90 910 386 Thermocouple 91 910 341 Thermopile 92 Rear Log 93 Left Top Log 94 Center Log 95 Middle Right ...

Page 30: ...26 Black Mitred Door Complete 730 932 Gold Wrap Door Complete 730 928 Gold Panel Door Complete 101 650 920 Door Gasket Kit 105 Ceramic Paper 106 940 323 P Side Glass 107 936 243 Glass Gasket 108 940 322 P Centre Glass 111 Door Frame Fibre Paper 112 750 015 Door Glass Extrusion 208 940 325 P Wrap Glass Not available as a replacement part ...

Page 31: ...ited lifetime warranty to the original purchaser of a Regency Product The Warranty Lifetime Covered under the agreement are the following components Combustion chamber heat exchanger burner tubes logs embers glass thermal breakage and all gold plating against defective manufacture The above will be covered for parts and labour for the first five years and parts only thereafter Electricalcomponentssu...

Reviews: