10
|
F1103S / F3103L
installation
MINIMUM CLEARANCE TO
COMBUSTIBLE MATERIALS
Please read the section below carefully as clearances depend on whether the airmate or the rear heat deflector is installed on the stove.
Measurements "From Unit" are from the top plate of the stove to a side wall or to a corner, and from the rear heat shield to a back wall.
Mobile Home Close Clearance (To be installed with required pipe components)
"C" Vent single wall pipe is not approved for Mobile Home installations. (Refer to Mobile Home Instructions.)
Unit
From Unit From Corner From Flue Center-line
A B C D E F
Small F1103S
with Airmate
11"
6"
6"
23"
12.5"
18"
with Rear Deflector
13"
5"
9"
25"
11.5"
21"
Large F3103L
with Airmate
18"
9.5"
10"
32"
16"
23.5"
with Rear Deflector
20"
12"
10"
34"
18.5"
23.5"
NOTE:
Be aware that local Codes and Regulations may override some clearances listed in this manual.
Check with your local inspector.
Residential Installation “C” Vent (Single Wall)
Unit
From Unit From Corner From Flue Center-line
A B C D E F
Small F1103S
with Airmate
13"
11"
8"
25"
17.5"
20"
with Rear Deflector
15"
10.5"
11"
27"
17"
23"
Large F3103L
with Airmate
18"
12"
8.5"
32"
18.5"
22"
with Rear Deflector
20"
14"
10.5"
34"
20.5"
24"
Residential Close Clearance (To be installed with required pipe components)
When the stove is installed as a close clearance residential unit, a listed double wall connector is required from the stove
collar to the ceiling level.
Unit
From Unit From Corner From Flue Center-line
A B C D E F
Small F1103S
with Airmate
9"
5"
3"
21"
11.5"
15"
with Rear Deflector
13.5"
5"
5"
25.5"
11.5"
17"
Large F3103L
with Airmate
16"
9.5"
8.5"
30"
16"
22"
with Rear Deflector
20"
12"
8.5"
34"
18.5"
22"