Clearances

Unless otherwise stated the clearances listed below are Minimum 
distances to combustible materials.  

Please Note: A major cause 

of chimney related 

fi

 res is due to a failure to maintain required 

clearances (air space) to combustible materials. It is of the greatest 
importance that this 

fi

 replace and vent system be installed only in 

accordance with these instructions.

Combustible Mantels

Because of the extreme heat this 

fi

 replace emits, the mantel 

clearances are critical.

 Combustible mantel clearances from top of 

the louvers are shown in the diagram below. Mantel may be installed 
anywhere in the shaded area or higher.

Note:  A non-combustible mantel may be installed at a lower 

height.

Note:  Ensure the paint that is used on the mantel and the facing 

is “heat resistant” or the paint may discolour.

Faceplate

Flush
with
Floor

Combustible

Flooring

Mantle

C

12" Max.

G

G

H

I

A

D

B

E

C

Clearances to Combustibles

Dimension

Description

U32

A

From Unit to Sides

10” (254mm)

B

From Unit to Ceiling

47.5” (1207mm)

C

From Unit to Mantel

see diagram 2 & 3

D

From Standard Surround to Sides

4” (102mm)

E

From Standard Surround to Ceiling

41.5” (1054mm)

also see diagram 2 & 3

G

Maximum Mantel Depth

12” (305mm)

see diagram 2

H

Minimum Alcove Width

48” (1219mm)

I

Maximum Alcove Depth

36” (914mm)

*

No Hearth Required

U32 Regency Gas Insert