F2500 Regency Freestanding Woodstove
31
Catalyst
maintenance
The catalytic thermometer on top of the stove should read in the active zone
after the stove has been in operation for several hours. If the thermometer's
indicator needle does not stay in the active zone, even with a hot fire, over a
period of regular use, the catalyst may need to be cleaned. If this persists it
may be necessary to replace it.
If the combustor must be examined or replaced, follow this procedure:
1. Allow the stove to burn out and cool down.
2. Remove stainless steel smoke deflector - See instructions in this manual.
3. Remove the front secondary air tube with pliers as shown below.
4. Remove baffles - push the baffles together and away from the side walls.
Combustor Assembly
Removal / Replacement
6. Manoeuver the baffle above the air tube and slide out.
8. Pull the flame shield forward and tilt down, be prepared to support catalyst
assembly.
9. Loosen bolts on catalyst retainer, slide the catalyst retainer to the right to
10. Reverse steps to reinstall catalyst.
Side View
Front View
Front View
5. Lift the left baffle out from underneath the right baffle - then lift out. Remove
the right baffle.
7. Remove locking clip from the front face of the Catalyst assembly by sliding
up and out.