Regency Bellavista B36XT Gas Fireplace

B36XT  Gas Fireplace

Rear Vent with Horizontal Termination

(see Diagram 1)

•   Can only use 5” x 8” venting

•   Maximum 20 ft. horizontal vent run

•   Use either 5” x 8” AstroCap

TM

 Flex Vent or approved Rigid Vent System 

with Rigid Pipe Adaptor (770-994)

•   Horizontal vent must be supported every 3 feet

Diagram 3

Diagram 4

Top Vent with Horizontal Termination

•   Top Vent Reducer [5” x 8” to 4’” x 6-5/8”]
 

- For use with Top Vent, Rigid Venting applications only. 

•   Must use Rigid Pipe Adaptor (770-994) and reducer (946-606) for all 

applications

•   Horizontal vent must be supported every 3 feet

•   Maximum 20 ft. horizontal vent run

     Top Vent - No Vertical Rise 

(see Diagram 3)

 

•     When venting with a 90

o  

elbow directly off the unit, must use 5” x  

      8” AstroCap

TM

 Flex Vent or approved Rigid Vent System

Top Vent  - With Vertical Rise  

(see Diagram 4)

•   All vent confi gurations can use either 5” x 8” or 4” x 6-5/8” (reducer 

required 946-606) approved Rigid Vent System.

Diagram 2

Diagram 1

Top Vent with Vertical Termination

(see Diagram 2)

•   All vent confi gurations can use either 5” x 8” or 4” x 6-5/8” (reducer 

required 946-606) approved Rigid Vent System.

•   Must use Rigid Pipe Adaptor (770-994) for all applications.

•   Maximum 40 ft. vent run