12 |
Regency CI1203 / CI1253 Wood Cast Insert
12 |
installation
6)
Install the unit by first setting the rear of the unit into the fireplace. See
diagram 3. Ensure that the unit is centered in the existing fireplace
and lined up with the flue adaptor.
7)
Slide the unit back until the flue adaptor is slightly engaged.
8
) At this point it is recommended to level the unit and ensure that the leveling
bolts rest on the surface of the fireplace. This will keep the adaptor from
binding as the unit is slid into position.
9)
Insert the provided pull rod through the hole in the top center of the unit.
Secure the threaded end into the flue adaptor as shown in diagram 4. While
sliding the unit into place pull on the rod to ensure that the flue adaptor is
properly engaged. See diagram 5.
Pull Rod
10)
Ensure that the unit is still level.
11)
To complete the installation and to ensure a secure fit and connection of
the flue adaptor to the insert, it is essential that the two bolts, flat wash
-
ers and lock washers (supplied with packaged manual) be installed and
tightened using a 1/2" socket as shown in diagram 6. This prevents the
possibility of creosote drip and exhaust gas leakage.
12)
Remove the pull rod from the top center of the fireplace. See diagram 7.
NOTE: The pull rod should not be thrown away. It should be kept if the
stove is ever needed to be removed from the fireplace.
Diagram 5:
Pull Rod In Place
Pull Rod
Diagram 3
Diagram 4
Diagram 6
Diagram 7