background image

Regency Albany Freestanding Wood Fire

9

MAINTENANCE

9)

  During the first few days it may be more 

difficult to start the fire. As you dry out your 

firebrick and your masonry flue, your draft 

will increase.

10)

 For those units installed at higher elevations 

or into sub-standard masonry fireplaces, 

drafting problems may occur. Consult an 

experienced dealer or mason on methods 

of increasing your draft.

11) 

Some cracking and popping noises may be 

experienced during the heating up process. 

These noises will be minimal when your unit 

reaches temperature.

12)

 Before opening your door to reload, open 

draft fully for approximately 10 to 15 seconds 

until fire has been re-established. This will 

minimize any smoking.

13)

 All fuel burning appliances consume oxygen 

during operation.  It is important that you 

supply a source of fresh air to your unit 

while burning. A slightly opened window is 

sufficient for the purpose.  If you also have 

a fireplace in your home, a downdraft may 

be created by your Regency Stove causing 

a draft down your chimney. If this occurs, 

slightly open a window near your unit.

CAUTION:  If the body of your unit, flue baffle 

or any part of the chimney connector starts 

to glow, you are overfiring.  Stop loading fuel 

immediately and close the draft control until 
the glow has completely subsided.

14) 

Green or wet wood is not recommended for 

your unit.  If you must add wet or green fuel, 

open the draft control fully until all moisture 

has  been  dispersed  by  the  intense  fire.  

Once all moisture has been removed, the 

draft control may be adjusted to maintain 

the fire.

15)

 If you have been burning your stove on a 

low draft, use caution when opening the 

door.  After opening the damper, open the 

door a crack, and allow the fire to adjust 

before fully opening the door.

16)

 The controls of your unit or the air supply 

passages should not be altered to increase 

firing for any reason.

17)

 If you burn the unit too slowly or at too low 

a setting your unit will not be operating as 

efficiently as it can.  An easy rule of thumb 

says that if your glass is clean, then your 

flue  is  clean  and  your  exhaust  is  clean.  

Burn the stove hot enough to keep your 

glass clean and you won't need to clean 

your flue as often.

   

CREOSOTE

When wood is burned slowly, it produces 

tar and other organic vapours, which when 

combined with moisture, form creosote. The 

creosote vapours condense in the relatively 

cool chimney flue of a slow burning fire. As a 

result, creosote residue accumulates on the flue 

lining.  When ignited, this creosote can result 

in an extremely hot fire.

WARNING:  Things to remember in case 

of a chimney fire:

1. Close all draft and damper controls.

2. CALL THE FIRE DEPARTMENT.

Ways to Prevent and Keep Unit 

Free of Creosote

1) 

Burn stove with the draft control wide open 

for about 10-15 minutes every morning 

during burning season.

2) 

Burn stove with draft control wide open for 

about 10 - 15 minutes every time you apply 

fresh wood. This allows the wood to achieve 

the charcoal stage faster and burns up any 

unburned gas vapours which might other-

wise be deposited within the system.

3)  Only burn seasoned wood!

  Avoid burning 

wet or green wood. Seasoned wood has 

been dried at least one year.

4) 

A  small  hot  fire  is  preferable  to  a  large 

smouldering one that can deposit creosote 

within the system.

WOOD STORAGE

Store wood under cover, such as in a shed, or 

covered with a tarp, plastic, tar paper, sheets 

of scrap plywood, etc., as uncovered wood can 

absorb water from rain or snow, delaying the 

seasoning process.

MAINTENANCE

It is very important to carefully maintain your 

fireplace  stove,  including  burning  seasoned 

wood and maintaining a clean stove and chim-

ney system. Have the chimney cleaned before 

the burning season and as necessary during 

the season, as creosote deposits may build up 

rapidly. Moving parts of your stove require no 

lubrication.

 

5) 

The chimney and chimney connector should 

be inspected at least once every two months 

during the heating season to determine is a 

creosote buildup has occured.

6)

 

Have chimney system and unit cleaned 

by competent chimney sweeps twice a 

year during the first year of use and at 

least once a year thereafter or when a 

significant layer of creosote has accu

-

mulated (3 mm/1/8" or more) it should be 

removed to reduce the risk of a chimney 

fire. 

GLASS MAINTENANCE

Your Regency stove is supplied with 5 mm 

Neoceram ceramic glass that will withstand 

the highest heat that your unit will produce.  In 

the event that you break your glass by impact, 

purchase your replacement from an authorized 

Regency dealer only, and follow our step-by-step 

instructions for replacement. 

Allow the stove to cool down before cleaning 

the glass, do not clean the glass when it is hot. 

Do not use abrasive cleaners.

 

Rear View of Door shown

Allen Screw

Latching 

Sleeve

Set

Screw

DOOR LATCH

ADJUSTMENT

The door latch may require adjustment as the 

door gasket material compresses over time.  

Follow  the  steps  below  to  allow  the  latch  to 

be moved closer to the door frame, causing a 

tighter seal;

1)

  Unscrew latching sleeve.

2)

  Remove allen screw.

3)

  Spin door handle clockwise to desired depth.

4)

  Re-install allen screw and latching sleeve.

5)

  Adjust set screw to proper depth to ensure  

       that the handle does not rotate 360 degrees.

Summary of Contents for Albany F200B-1

Page 1: ... additional information consult an authorised installer service agency or the distributor FOR YOUR SAFETY Do not store or use petrol or other flammable vapours and liquids in the vicinity of this or any other appliance Installation and service must be performed by an authorised installer service agency or the gas supplier Model F200B 1 Albany F200B 1 Freestanding Wood Fire FPI FIREPLACE PRODUCTS A...

Page 2: ...wood fire is not properly installed a house fire may result For your safety follow the installation instructions contact local building fire officials or authority having jurisdiction about restrictions and installation inspection requirements in your area The authority having jurisdiction should be consulted before installation to determine the need to obtain a permit ONLY CLEAN APPLIANCE WITH A ...

Page 3: ...rnings 6 Cast Plate Installation 6 Clearance to Combustibles 7 Floor Protection 7 OPERATING INSTRUCTIONS Operating Instructions 8 Air Slide Control 8 First Fire 8 MAINTENANCE Maintenance 9 Creosote 9 Ways to Prevent Keep Units Free of Creosote 9 Glass Maintenance 9 Door Latch Adjustment 9 Wood Storage 9 PARTS LIST Stove Assembly 10 WARRANTY Warranty 11 ...

Page 4: ... the label that accompanies each F200B 1 Freestanding Wood Fire We have printed a copy of the contents here for your review NOTE Regency units are constantly being improved Check the label on the unit and if there is a difference the label on the unit is the correct one ...

Page 5: ...Regency Albany Freestanding Wood Fire 5 UNIT DIMENSIONS ...

Page 6: ...recom mends that your unit is secured to the floor by using the bolt down holes inside the pedestal 11 Do not connect this unit to a chimney serving another appliance SAFETY GUIDELINES AND WARNINGS 1 Never use petrol petrol type lantern fuels kerosene charcoal lighter fuel or similar liquids to start or freshen up a fire in your heater Keep all such liquids well away from the heater while it is in...

Page 7: ...mm sheets of cement fibre sheet The flue pipe shall extend not less than 4 6m above the top of the floor protector NOTE Installation must be carried out by a licensed installer in accordance with AS NZS 2918 2001 IMPORTANT 1 The Hawkwind Standard flue kit requires one 130o x 900mm stainless reflective shield between the decromesh casing and active flue 2 The AHD Special Insulated flue kit must be ...

Page 8: ...le OPERATING INSTRUCTIONS With your unit now correctly installed and safety inspected by your local authority you are now ready to start a fire Before establishing your first fire it is important that you fully understand the operation of your draft control CAUTION THIS APPLIANCE MUST BE MAINTAINEDANDOPERATEDATALLTIMES IN ACCORDANCE WITH THESE INSTRUC TIONS CAUTION THE USE OF SOME TYPES OF PRESERV...

Page 9: ...in an extremely hot fire WARNING Thingstorememberincase of a chimney fire 1 Close all draft and damper controls 2 CALL THE FIRE DEPARTMENT Ways to Prevent and Keep Unit Free of Creosote 1 Burn stove with the draft control wide open for about 10 15 minutes every morning during burning season 2 Burn stove with draft control wide open for about 10 15 minutes every time you apply freshwood Thisallowst...

Page 10: ... Neoceram with Gasket 7 8010612 Door Assembly without handle 8 8010114 Door Handle Set 9 8010104 Secondary Air Tube 10 8010108 Firebrick optional or where fitted x 16 11 Pedestal Assembly 12 8010609 Ashlip Panel 13 8010610 Fan Assembly Complete 8010611 Steel baffle A 7510206 Cast Plate Set B 14 8010113 Metal lip inside firebox 15 8010115 Glass retaining bracket 16 936 060 Door rope seal 5 ft not s...

Page 11: ...is the general practice of Regency Fireplace Products to charge for larger higher priced replacement parts and issue credit once the replaced component has been returned to Regency Fireplace Products and evaluated for manufacturer defect The authorised selling dealer is responsible for all in field service work carried out on your Regency product Regency Fireplace Products will not be liable for r...

Page 12: ..._____________________________________________________ Serial No ___________________________________________________________ Register your Regency warranty online www regency fire com au Reasons to register your product online today View and modify a list of all your registered products Request automatic email notification of new product updates Stay informed about the current promotions events and...

Reviews: