5
G51 Zero Clearance Kit
INSTALLATION
A
D
E
C
F
B
LOCATING YOUR G51 FIREPLACE
Due to high temperatures the Insert should be located out of traffic and
away from furniture and draperies. Provide a minimum of 48" (1220mm)
front clearance to the unit.
This appliance is Listed for Alcove installations, maintain minimum
Alcove clearances as follows, minimum ceiling height of 65.5"(1666mm),
minimum width of 56.5" (1435 mm) and a maximum depth of 36"
(915 mm).
This unit is not approved for installation into a mobile home.
FRAMING
1)
The trim kit allows for 1/2" (13 mm) of finish non-combustible facing material. The kit may be installed directly on
and/or against standard combustible building materials.
2)
Frame in the Zero Clearance box for the Kit with framing material.
3)
For exterior walls, vapour barrier and insulate the Zero Clearance box to the same degree as the rest of the house,
or according to local installation codes.
4)
The appliance may be enclosed above the standoffs on the cabinet but the clearances stated on the b-vent chimney
must be maintained.
a) Cross Corner
d) Island
b) Room Divider
e) Flush with Wall
c)
Flat on wall
f)
Flat on Wall
Corner
Framing Dimensions
A
B
C
839mm 1118mm 428mm
Warning: Combustible materials must not extend inside
the stand-offs on the side, top and rear supports. For
safety reasons do not modify or alter any components of
the 390-900 kit.