background image

14

 | 

Regency

®

 U39-12 ULTIMATE™ Freestanding Gas Stove

installation

4” x 6-5/8” Rigid Pipe Cross Reference Chart

Components from different Manufacturers may not be mixed.  Not All Rigid Pipe components are available directly from FPI.

Note: 

Olympia Ventis DV venting is only approved for certain models. See list of approved models in cross-reference chart.

Description

Simpson
Direct Vent Pro®

*Selkirk
Direct Temp™

*American Metal
Products®
Amerivent Direct

*Metal-Fab™
Sure Seal

*Security
Secure- Vent®

*ICC Excel 
Direct

*Olympia
Ventis DV***

6" Pipe Length-Galvanized

46DVA-06

4DT-6

N/A

4D6

SV4L6

TC-4DL6

VDV-0406

6" Pipe Length-Black

46DVA-06B

4DT-6B

N/A

4D6B

SV4LB6

TC-4DL6B

VDVB-0406

7" Pipe Length-Galvanized

N/A

N/A

4D7

N/A

N/A

N/A

N/A

7" Pipe Length-Black

N/A

N/A

4D7B

N/A

N/A

N/A

N/A

9" Pipe Length-Galvanized

46DVA-09

4DT-9

N/A

N/A

N/A

TC-4DL9

VDV-0409

9" Pipe Length-Black

46DVA-09B

4DT-9B

N/A

N/A

N/A

TC-4DL9B

VDVB-0409

12" Pipe Length-Galvanized

46DVA-12

4DT-12

4D12

4D12

SV4L12

TC-4DL1

VDV-0412

12" Pipe Length-Black

46DVA-12B

4DT-12B

4D12B

4D12B

SV4LB12

TC-4DL1B

VDVB-0412

18" Pipe Length-Galvanized

46DVA-18

4DT-18

4D18

4D18

SV4LA

TC-4DL18

VDV-0418

18" Pipe Length-Black

46DVA-18B

4DT-18B

4D18B

4D18B

SV4LA

TC-4DL18B

VDVB-0418

24" Pipe Length-Galvanized

46DVA-24

4DT-24

4D24

4D24

SV4L24

TC-4DL2

VDV-0424

24" Pipe Length-Black

46DVA-24B

4DT-24B

4D24B

4D24B

SV4LB24

TC-4DL2B

VDVB-0424

36" Pipe Length-Galvanized

46DVA-36

4DT-36

4D36

4D36

SV4L36

TC-4DL3

VDV-0436

36" Pipe Length-Black

46DVA-36B

4DT-36B

4D36B

4D36B

SV4LB36

TC-4DL3B

VDVCB-0436

48" Pipe Length-Galvanized

46DVA-48

4DT-48

4D48

4D48

SV4L48

TC-4DL4

VDV-0448

48" Pipe Length-Black

46DVA-48B

4DT-48B

4D48B

4D48B

SV4LB48

TC-4DL4B

VDVB-0448

60" Pipe Length-Galvanized

46DVA-60

4DT-60

N/A

N/A

N/A

N/A

N/A

60" Pipe Length-Black

46DVA-60B 

4DT-60B

N/A

N/A

N/A

N/A

N/A

Adjustable Length 3"-10"-Galvanized

N/A

N/A

N/A

4DAL

N/A

TC-4DLT

N/A

Adjustable Length 3"-10"-Black

N/A

N/A

N/A

4DALB

N/A

TC-4DLTB

N/A

Adjustable Length 7)-Galvanized

N/A

N/A

4D7A

N/A

N/A

N/A

N/A

Adjustable Length  7"-Black

N/A

N/A

4D7AB

N/A

N/A

N/A

N/A

Extension Pipe 8-1/2"-Galvanized

46DVA-08A

N/A

N/A

N/A

N/A

N/A

N/A

Extension Pipe 8-1/2"-Black

46DVA-08AB

N/A

N/A

N/A

N/A

N/A

N/A

Adjustable Length 12"-Galvanized

N/A

N/A

4D12A

N/A

SV4LA12

TC-4dLSI

N/A

Adjustable Length 12"-Black

N/A

N/A

4D12A

N/A

SV4LBA12

TC-4dLSIB

N/A

Extension Pipe 16"-Galvanized

46DVA-16A

N/A

N/A

N/A

N/A

N/A

N/A

Extension Pipe 16"-Black

46DVA-16AB

N/A

N/A

N/A

N/A

N/A

N/A

45

º

 Elbow-Galvanized

46DVA-E45

4DT-EL45

4D45L

N/A

N/A

TE-4DE45

VDV-EL0445

45

º

 Elbow-Black

46DVA-E45B

4DT-EL45B

4DT-EL45B

N/A

N/A

TE-4DE45B

VDVB-EL0445

45

º

 Elbow Swivel-Galvanized

See 46DVA-E45

N/A

N/A

4D45L

SV4E45

N/A

N/A

45

º

 Elbow Swivel-Black

See 46DVA-E45B

N/A

N/A

4D45LB

SV4EB45

N/A

N/A

90

º

 Elbow-Galvanized

46DVA-E90

4DT-EL90S

4DT-EL90S

N/A

N/A

TE-4DE90

VDV-EL0445

90

º

 Elbow-Black

46DVA-E90B

4DT-EL90SB

4DT-EL90SB

N/A

SV4EBR90-1

TE-4DE90B

VDVB-EL0445

90

º

 Elbow, Swivel-Galvanized

See 46DVA-E90

N/A

N/A

4D90L

SV4E90-1

N/A

N/A

90

º

 Elbow, Swivel-Black

See 46DVA-E90B

N/A

N/A

4D90LB

wSV4EB90-1

N/A

N/A

90

º 

Starter Elbow, Swivel-Galvanized

N/A

N/A

N/A

4D90A

N/A

N/A

N/A

Adaptor*

N/A

N/A

N/A

4D90L

N/A

N/A

VDV-UAA04

4" X 6-5/8" RIGID PIPE CROSS REFERENCE CHART

Components from different Manufacturers may not be mixed.  Not all rigid pipe components are available directly from Regency.

Note:

 Olympia Ventis DV venting is only approved for certain models. See list of approved models in cross-reference chart.

Ceiling Support

N/A

4DT-CS

4DSP

4DFSP

SV4SD

TM4-RDS

VDV-SCR04

Cathedral Support Box

46DVA-CS

4DT-CSS

4DRSB

4DRS

SV4CSB

TM4-SDS

VDV-CSS04

Wall Support/Band

46DVA-WS

4DT-WS/B

4DWS

4DWS

SV4BM

TM-SWS

VDV-WS04

Offset Support

46DVA-ES

 

4DT-OS

N/A

N/A

SV4SU

TM-SOS

N/A

Wall Thimble-Black

46DVA-WT

4DT-WT

4DWT

4DWT

SV4RSM

N/A

VDV-WPT04

Wall Thimble Cover/Ceiling Support

46DVA-DC

 

N/A

N/A

N/A

SV4PF

N/A

N/A

Firestop Spacer

46DVA-FS

4DT-FS

4DFSP

4DFS

SV4BF

TM-4CS

VDV-FS04

Trim Plate-Black

N/A

4DT-TP

4DFPB

4DcP

SV4LA

TM-4TP

VDV-WTC04

* Not available from Regency

Summary of Contents for U39-NG12

Page 1: ...ilding immediately Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and se...

Page 2: ...d by Intertek for both safety and efficiency As it also bears our own mark it promises to provide you with economy comfort and security for many trouble free years to follow Please take a moment now t...

Page 3: ...ertical Terminations 24 Cathedral Ceilings 25 Converting a Class A Metal Chimney to a Direct Vent System 26 System Data 27 Gas Connection 27 High Elevation 27 Conversion from NG to LP 28 Conversion to...

Page 4: ...39 12 ULTIMATE Freestanding Gas Stove dimensions ALL PICTURES DIAGRAMS SHOWN THROUGHOUT THIS MANUAL ARE FOR ILLUSTRATION PURPOSES ONLY ACTUAL PRODUCT MAY VARY DUE TO PRODUCT ENHANCEMENTS 913 16 250mm...

Page 5: ...s vitr es certi es avec l appareill VENTED GAS FIREPLACE HEATER NOT FOR USE WITH SOLID FUELS FOYER AU GAZ VACUATION NE PAS UTILISER AVEC UN COMBUSTIBLE SOLIDE Made in Canada Fabriqu au Canada Listed V...

Page 6: ...irectly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT D...

Page 7: ...it converted to top or rear vent per manual instructions and the insulation discarded Venting YES NO Are the venting components approved for the unit installed Does the venting configuration comply wi...

Page 8: ...the air shutter on the proper setting after running the unit for 20 minutes If applicable were the surround and trims installed according to the manual Was the operation of the fan lights if installed...

Page 9: ...E KEPT CLEAN DUE TO HIGH TEMPERATURES THE APPLIANCE SHOULD BE LOCATED OUT OF TRAFFIC AND AWAY FROM FURNITURE AND DRAPERIES WARNING FAILURE TO INSTALL THIS APPLIANCE CORRECTLY WILL VOID YOUR WARRANTY A...

Page 10: ...es for servicing proper operation and around the air openings into the combustion chamber 2 The appliance may be installed on a flat solid continuoussurface e g wood metal concrete This may be the flo...

Page 11: ...onnected to the specifiedventandterminationcaptotheoutside of the building envelope Never vent to another room or inside a building Make sure that the vent is fitted as per the instructions starting i...

Page 12: ...balanced flue technology Co Axial system The inner liner vents products of combustion to the outside while the outer pipe draws outside combustion air into the combustion chambertherebyeliminatingthen...

Page 13: ...ended above meter regulator assembly 36 90cm a J Clearance to service regulator vent outlet 36 90cm K Clearance to non mechanical air supply inlet to building or the combustion air inlet to any other...

Page 14: ...ack N A N A N A 4DALB N A TC 4DLTB N A Adjustable Length 7 Galvanized N A N A 4D7A N A N A N A N A Adjustable Length 7 Black N A N A 4D7AB N A N A N A N A Extension Pipe 8 1 2 Galvanized 46DVA 08A N A...

Page 15: ...onal for AstroCap 946 205 Vinyl Siding Shield for Riser Vent Terminal 510 994 Rigid Pipe Adaptor Must use with all rigid piping 946 208 P Vent Guard Optional for Riser Vent Terminal 640 530 P Riser Ve...

Page 16: ...nents WARNING Do not combine venting components from different venting systems However use of the the AstroCapTM and FPI Riser is acceptable with all systems When using Rigid Vent other than Simpson D...

Page 17: ...ways maintain required clearances air spaces to nearby combustibles to prevent a fire hazard Do not fill air spaces with insulation Be sure to check the vent termination clearance requirements from de...

Page 18: ...The shaded areas in the diagram below show all allowable combinations of vertical runs with horizontalterminations Maximumone90O elbow two 45o elbows equal one 90o elbow Propane and Natural Gas Reside...

Page 19: ...total vertical and maximum 4 feet total horizontal Please note minimum 1 foot between 90o elbows is required Lengthsdonotincludeelbowindicated One 90o elbow Two 45o elbows Option V H V1 V V1 A 1 Min...

Page 20: ...desired location Check to determine if wall studs will be in the way of the venting system adjust location until all clearances are met and there are no obstructions Note A1 1 2 38mm clearancearoundth...

Page 21: ...3 of the 8 x 1 2 black screws Pipe seams should be facing the wall 16 Attach the 90o elbow onto the pipe section by sealing with Mill Pac and securing with 3 of the 8 x 1 2 screws black 17 Slide the a...

Page 22: ...it flue outlet to the ceiling the ceiling thickness the vertical rise in an attic or second storey and allowforsufficientverticalheightabovetheroofline Formulti storeyapplications firestopsarerequired...

Page 23: ...e terminated If the wall being penetrated is constructed of non combustible material i e masonry block or concrete a 7 diameter hole is acceptable Diagram 3 Dura Vent Horizontal Terminations 1 Set the...

Page 24: ...concealed by the decorative wall thimble cover See diagram 6 4 If installing the vent termination to a wall with vinyl siding the Vinyl Siding Standoff must be used Attach the Vinyl Siding Standoff to...

Page 25: ...in the attic as well as above the roofline The galvanized finish is desirable above the roofline due to its higher corrosion resistance Continue to add pipe sections through the flashing until the hei...

Page 26: ...least a 2 inch overlap where the extension joins the support General Prior to installation and connection of the vent system to a Class A chimney the chimney must be inspected and thoroughly cleaned b...

Page 27: ...rt 730 920 For Natural Gas installations above 4500 ft follow current CAN CGA B149 1 In U S A for installations above 2000 ft refer to current ANSI Z223 1 Sc8 8 1 2a appendix F for resizing orifice Sy...

Page 28: ...fice in the kit 11 Reinstall new burner orifice LPG stamped 49 and tighten 13 Check for gas leaks with a proper soapy solution or leak detector 14 Check for proper spark between the ignitor and pilot...

Page 29: ...ten the screw clockwise with a 1 8 flat screwdriver Note Screw should be snug but do not over tighten THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION 920 1...

Page 30: ...n use the Allen key to turn the turning gear which will adjust the air shutter Open the air shutter for a blue flame or close it for a yellow flame Note Any damage due to carboning resulting from impr...

Page 31: ...pport A B 3 Place the Middle Left Log B on the two pins as shown The gas log kit contains the following a 02 65 Rear Log b 02 56 Middle Left Log c 02 44 Front Left Log d 02 46 Left Top Log e 02 45 Fro...

Page 32: ...urner tray E Bracket The bottom right edge of Log G must sit snugly against the bracket Side View G 9 TaketheEmbaglow steelwoollikematerial lightlyseparate it and set a small amount over the visible b...

Page 33: ...burner to the other If there is any flame hesitation check that area for any blockage of the burner port F 0 2 4 7 E 02 45 A 02 65 G 02 48 D 0 2 4 6 B 02 56 C 02 44 11 Using the harder coal like ember...

Page 34: ...dle Left Log B on the two pins as shown The driftwood log kit contains the following A Rear Log B Middle Left Log C Front Left Log D Left Top Log E Front Right Log F Center Log G Middle Right Log C 4...

Page 35: ...tray E Bracket The bottom right edge of Log G must sit snugly against the bracket Side View G 9 TaketheEmbaglow steelwoollikematerial lightlyseparate it and set a small amount over the visible burner...

Page 36: ...ows smoothly from one end of burner to the other If there is any flame hesitation check that area for any burner port blockage 11 Using the harder coal like embers carefully spread these around the OU...

Page 37: ...ngpowertothereceptaclebox provided with the unit in case the fan is installed at a later date Caution Ensure that the wires do not touch any hot surfaces and are away from sharp edges CAUTION Labelall...

Page 38: ...adjusting the primary air to ensure that the flame does not carbon First allow the unit to burn for 15 min to stabilize 3 Check for proper draft CAUTION Any alteration to the product that causes sooti...

Page 39: ...ery difficult to remove Use a non abrasive cleaner and NEVER clean the glass while it is hot Proflame vid eo DO NOT BURN THE APPLIANCE WITHOUT THE GLASS FRONT IN PLACE NOTE This appliance will operate...

Page 40: ...can cause injury or property damage Refer to the owner s information manual provided with this appliance For assistance or additional information consult a qualified installer service agency or gas su...

Page 41: ...in the unit these sounds will likely re occur Again this is normal for steel fireboxes Blower Thermodisc When this thermally activated switch turns ON it will create a small clicking sound This is the...

Page 42: ...PROFLAME Transmitter Blue LCD display UP DOWN Arrow Key ON OFF Key THERMOSTAT Key MODE Key Low battery alarm Child safety lock out Room Temperature Aux ON Set Point Temperature Level State Flame ON Th...

Page 43: ...il the desired set temperature is dis played on the LCD screen of the Transmitter Remote Flame Control The Proflame GTMF has six 6 flame levels With the system on and the flame level at the maximum in...

Page 44: ...peration Toactivatethisfunction presstheMODEandUPKeysatthesametime fig 18 To de activate this function press the MODE and UP Keys at the same time Low Battery Power Detection Transmitter The life span...

Page 45: ...condensation and fog is normal and will disappear in a few minutes as the glass heats up Never operate the appliance without the glass properly secured in place or with the door open 8 Periodically ch...

Page 46: ...er warranty Door Gasket If the door gasket requires replacement use 7 8 diameter oval door gasket Part 732 570 Latch Adjustment The door latch may require adjustment as the door gasket material compre...

Page 47: ...move the grounding prong from this plug To Remove U39 Fan from front of Unit 1 Unplug or disconnect power source to stove 2 Remove all logs and the rear log support then remove the 10 screws holding t...

Page 48: ...ant to put a soft cloth on the base of the unit so that when the pedestal door is open it doesn t scratch the paint 2 Remove 2 screws to remove receiver cover 3 Remove chain from door and unit remove...

Page 49: ...licensed gas service technician during the annual service check Your unit may require more frequent maintenance checks if you notice any changes in how it operates Operational changes to look for can...

Page 50: ...ouver Assy Black 9 732 513 Relief Door Assembly 10 732 022 Mounting Plate Gasket 11 730 517 P Fan Assembly 910 331 P Fan Motor 120 Volt 12 910 813 Power Cord 120 Volt 15 Pedestal Assembly 16 730 039 P...

Page 51: ...08 Gasket Burner Tray Firebox 78 734 550 Burner Assembly NG LP 80 260 565 Air Shutter Gear Assembly Female 81 904 565 Hex Key 3 16 AF 82 630 009 Gasket Burner Tray Air Passage 84 Air Shutter Gear Asse...

Page 52: ...scription 209 732 943 Black Wrap Door Complete 732 944 Brushed Nickel Wrap Door Complete 101 732 570 Door Gasket Kit 105 Ceramic Paper 107 936 243 Glass Gasket 111 Door Frame Fibre Paper 208 940 325 P...

Page 53: ...Regency U39 12 ULTIMATE Freestanding Gas Stove 53 notes...

Page 54: ...ontrol Boards Wiring Switches Blowers Blower Control Module Battery Pack Remote Control Systems 2 Enamel Panels 1 Venting Venting Components 1 All Stainless steel surrounds 1 All Firebox Media Crystal...

Page 55: ...rafts installation error installation by an unqualified installer incorrect chimney components including but not limited to cap size or type operator error abuse misuse use of improper fuels lack of r...

Page 56: ...the U S should consult their local provincial or national legal codes for additional terms which may be applicable to this warranty How to Obtain Warranty Service Customers should contact the authori...

Page 57: ...w in order for us to serve you better Warranty Registration Form or Register online immediately at the above Web Site Warranty Details Serial Number required Purchase Date required mm dd yyyy Product...

Page 58: ......

Page 59: ......

Page 60: ...ation Dealer Name Address _______________________________________________ ___________________________________________________________________ Installer ________________________________________________...

Reviews: