Diagram 2
4)
Lift fan off of the 2 pins, tip back and pull
through firebox opening. Disconnect the
green ground wire from the left side of the
fan as soon as you can reach it.
Replacing U28 Fan:
Reverse the above steps (1 - 4). If necessary
install a new gasket before replacing the fan
access panel. Make sure the fan wires and the
ground wire are reattached.
Diagram 1
To remove U28 fan:
1)
Unplug or disconnect power source to stove.
2)
Remove all logs and the rear log support,
then remove the 10 screws holding the
access panel in place, see Diagram 1. (Fan
is also accessible by opening the right side
door. See Diagram 2).
3)
Unclip the black and white wires from the
fan motor.
4)
Remove the two outside frame pieces by
removing two screws per side. See diagram
below.
REMOVING VALVE
If your valve requires maintenance or replace-
ment, follow these instructions:
NOTE: Always shut off the gas supply
before removing the valve.
1)
Open front pedestal door and unhook chain.
You may want to put a soft cloth on the base
of the unit so that when the pedestal door
is open it doesn't scratch the paint. See
diagram below.
2)
Undo the six screws holding the control
panel in place.
3)
Disconnect all wires from the back of the
panel and then remove panel. You should
lay the panel on a soft cloth so it doesn't get
marked up. See diagram below.
5
) Carefully remove the logs, embers and
rockwool.
6)
At this point you should disconnect the gas
at the valve.
7)
Remove the burner by removing the two
1/4" hex head screws. See diagram below.
8)
Remove eight 1/4" hex head
screws holding the burner tray assembly
in place.
9)
Carefully lift the burner tray assembly out.
10)
To replace the burner tray assembly, simply
reverse these instructions.
Note: Use a
magnetic type
screwdriver.