WARRANTY

Regency

®

 Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each 

unit thoroughly before it leaves our door. Regency® is pleased to extend this limited lifetime warranty to the  original purchaser of a Regency

®

 Product.

The Warranty:  

Lifetime

Covered under the agreement are the following components: The combustion chamber, heat exchanger, burner tubes/pans, logs, glass crystals, ceramic spa stones, 
pebbles, brick panels and gold plating (against defective manufacture only) are covered under the Limited Lifetime Warranty for fi ve (5) years for parts and labour and 
parts only thereafter.

External casting, surrounds and grills are covered against cracks and warps resulting from manufacturer defects, parts and labour for one (1) year from the date of 
purchase and parts only thereafter.

Special Finishes - One year on stainless steel panels, nickel overlays, nickel faceplates, brushed nickel and antique copper full screens and doors. You can expect 
some changes in color as the product "ages" with constant heating and cooling. Regency warranties the product for any manufacturing defects on the original product. 
However, the manufacturers warranty does not cover changing colors and marks, ie. fi nger prints, etc applied after the purchase of the product. Damage from the use 
of abrasive cleaners is not covered by warranty.

Electrical components such as fans, switches, ignition modules, wiring, thermodiscs, remote control, thermopiles, thermocouples and gas valves are covered for one 
year for parts and labour from the date of purchase.

The warranty on brass parts is for one year, no labour. The brass is not warranted against tarnishing.

Repair/replacement parts purchased by the consumer from Regency

®

 after the original coverage has expired on the unit will carry a 90 day warranty valid with a receipt 

only.  Any item shown to be defective will be repaired or replaced at our discretion.  No labour coverage is included with these parts.

Conditions:

All installations must be performed by a qualifi ed gas fi tter and installed according to all applicable local and national codes.  Also, all service work must be carried out 
by a qualifi ed gas service person provided by the selling dealer.  It is the responsibility of the installer to ensure that the appliance is fi ring as per rating plate.  Any part 
or parts of this unit which in our judgement show evidence of such defect will be repaired or replaced at Regency

®

's option, through an accredited distributor or agent 

provided that the defective part be returned to the distributor or agent 

Transportation Prepaid,

 if requested. In areas where there is not an approved service agent or 

the closest approved service agent is situated more than thirty (30) kilometres from the installation, Regency is not obliged to arrange warranty repairs and travel and/
or additional labour charges will apply.

Porcelain/Enamel - Absolute perfection is neither guaranteed nor commercially possible.  Any chips must be reported and inspected by an authorised dealer within three 
days of installation.  Reported damage after this time will be subject to rejection.

It is the general practice of Regency

®

 to charge for larger, higher priced replacement parts and issue credit once the replaced component has been returned to Regency 

and evaluated fro manufacturer defect.
At all times Regency reserves the right to inspect product in the fi eld which is claimed to be defective.

All claims must be submitted to Regency

®

 by authorised selling dealers.  It is essential that all submitted claims provide all of the necessary information including customer 

name, purchase date, serial #, type of unit, problem, and part or parts requested, without this information the warranty will be invalid.

Exclusions:

This limited Lifetime Warranty does not extend to or include paint, door or glass gasketing or trim.  It does not cover installation and operational related problems such as 
over-fi ring, downdrafts or spillage caused by environmental conditions, nearby trees, buildings, hilltops, mountains, inadequate fl ueing or ventilation, excessive offsets, 
negative air pressures caused by insuffi cient make up air, mechanical systems such as furnaces, fans, clothes dryers etc.

Embers, rockwool, gaskets, door handles and paint are not covered under the terms of this warranty policy.

Regency

®

 will not be liable for acts of God, or acts of terrorism, which cause malfunction of the appliance.

Performance problems due to operator error will not be covered by this warranty policy.

The warranty does not extend to any part or parts which show evidence of misuse or abuse, neglect, accident, lack of maintenance, or improper installation.

Products made by other manufacturers and used in conjunction with the operation of this appliance without authorisation from Regency

®

, may nullify your warranty on 

this product.

Regency shall in no event be liable for any special, indirect consequential damages of any nature whatsoever which are in excess of the original purchase price of the 
product. Any alteration to the unit which causes sooting or carboning that results in damage to the exterior facia is not the responsibility of Regency Fireplace Products.

SUBJECT TO CHANGE.

DISTRIBUTORS:

Western Australia

Eastern Australia

Air Group Australia

Fireplace Products Australia PTY. Ltd.

28-30 Division St.

1-3 Conquest Way

Welshpool, WA   6106

Hallam, VIC 3803

08 9350 2200

03 9799 7277

NOTE: PLEASE  RETAIN YOUR INVOICE AS PROOF OF PURCHASE FOR WARRANTY 

VERIFICATION

INCORRECT INSTALLATION OR GAS PRESSURE SETTINGS ARE NOT COVERED BY 

WARRANTY

A SERVICE OR CALLOUT FEE WILL BE CHARGED IN THESE CIRCUMSTANCES.

Summary of Contents for IG34-LPG

Page 1: ...ht any appli ance Do not touch any electri cal switch do not use any phone in your building Immediately call your gas supplierfromaneighbour s phone Follow the gas sup plier s instructions If you cann...

Page 2: ...you with all the warmth and charm of a fireplace at the flick of a switch The model IG34 of this series has been approved by Australian Gas Association for both safety and efficiency As it also bears...

Page 3: ...stall 14 Log set installation 15 Glass Door installation 18 Standard Flush Door 18 Optional Flush Trim Faceplate Optional plinth trim Assembly 19 Faceplate and door frame Installation 20 Thermodisc in...

Page 4: ...the unit and if there is a difference the label on the unit is the correct one DO NO T DO NO T DO NO T DO NO T DO NO T DO NO T OPERATE THIS APPLIANCE BEFORE READING THE INSTRUCTIONS BOOKLET PLACE ARTI...

Page 5: ...ion 7 Anysafetyglassremovedforservicingmust bereplacedpriortooperatingtheappliance 8 To prevent injury do not allow anyone who is unfamiliar with the operation to use the fireplace 9 Installer must me...

Page 6: ...ney above the appliance Move the appliance into the exact location where it is to be installed Ensure that the Insert is level C L Gas Inlet FLUEING This appliance is designed to be attached to two 3...

Page 7: ...r tighten S I T Valve Description 1 On Off Solenoid Valve EV1 2 On Off Solenoid Valve EV2 3 Inlet Pressure Test Point 4 Outlet Pressure Test Point 5 Connection for Pressure Regulator Combustion Chambe...

Page 8: ...te over the tow ends of the Flex Liner and secure it to the sur rounding masonry using masonry anchor bolts Before installing the baseplate run a bead of non hardening seal and between the Baseplate a...

Page 9: ...ting controls is NOT covered under warranty INSTALLATION IG34 NG For 0 to 610 meters altitude IG34 LPG For 0 to 610 meters altitude IG34 ULPG For 0 to 610 meters altitude Burner Inlet Orifice Sizes NG...

Page 10: ...nd discard Use a wrench to hold on to the elbow behind the orifice Control Box Cover Antenna Jumper Location 16 Remove the jumper using a plier 7 Reinstall new burner orifice LPG stamped 51 and tighte...

Page 11: ...control 23 Check for proper flame appearance and glow on logs C B A 18 Turn on gas supply and plug in power cord 19 Adjusting the Outlet Pressure All the adjustments must be carried out in the followi...

Page 12: ...discard Use a wrench to hold on to the elbow behind the orifice Control Box Cover Antenna Jumper Location 16 Remove the jumper using a plier 7 Reinstall new burner orifice ULPG stamped 53 and tighten...

Page 13: ...tic cap A using needle nose pliers Maximum pressure Turn the unit ON to its highest input rating Screw in the nut B to increase the outlet pressure and screw it out to decrease it Use a 10 mm wrench N...

Page 14: ...ceplate inner door frame and screen if already installed Refer to page 18 in the instruction manual 2 Remove the glass door by undoing 2 latches lift up and out Refer to page 17 in the manual for deta...

Page 15: ...79 P Vermiculite k 946 669 Platinum Embers supplied with packaged manual Note Install Optional Brick Panels prior to installing logs 1 Carefully remove the logs from the box and unwrap them The logs a...

Page 16: ...02 45 and across the cutout on Log A 02 43 Cutout Pin Cutout Notch 8 Position notch in Front Right Log F 02 48 on Log E 02 47 and push the bottom right edge against the bracket on the burner tray and...

Page 17: ...t the bracket and the front edge of the rear burner Side View 11 Separate platinum embers and place on and around the embers and rockwool on the burner tray Avoid stacking platinum embers 12 Test fire...

Page 18: ...rds the unit diagram 1 Be careful that the glass gasket does not roll up there must be a gap between the gasket and the door lip to ensure that the door sits securely on the unit See Diagram 2 Use the...

Page 19: ...els flat face down on something soft so they don t scratch 2 Take the top faceplate and align the holes in it with the holes in the side panels Secure with provided nuts and bolts 3 Install faceplate...

Page 20: ...ing the back of the faceplate with supplied grey adhesive clips 2 Take the limit switch harness from the unit and slide the thermodisc into the bracket located on the top backside of the faceplate Se...

Page 21: ...tom frame is positioned properly before installing by making sure there is equal spacing on either side 7 Install lower screw below glass door secure with 4 screws 8 Flip bottom louver up to close 9 I...

Page 22: ...he unit to burn for 15 min to stabilize 3 Check for proper draft CAUTION Any alteration to the product that causes sooting or carboning that results in damage to the exterior facia is not the responsi...

Page 23: ...E Whentheglassiscoldandtheappliance is lit it may cause condensation and fog the glass This condensation is normal and will disappear in a few minutes as the glass heats up DO NOT ATTEMPT TO CLEAN THE...

Page 24: ...at as there are temperature changes within the unit these sounds will likely re occur Again this is normal for steel fireboxes Gas Control Valve As the gas control valve turns ON and OFF a dullclickin...

Page 25: ...lames are steady not lifting or floating If there is a problem call an authorized service person 4 The appliance and flueing system must be inspected before use and at least annu ally by an authorized...

Page 26: ...and screen 6 Remove the ECS harness from the back clip 7 Pull out the ECS box NOTE The ECS box is held in place with velcro 8 Remove the 2 screws that secure the fan in place 9 Carefully slide the fa...

Page 27: ...e the glass door logs and black or stainless inner liner if installed 5 Remove the rear log tray burner and grate 6 Disconnect gas line from the valve 7 Remove the firebox base plate by removing the 1...

Page 28: ...N A N A N A 910 084 Control Box 910 527 Manual Control Switch N A N A N A N A 910 080 Valve 910 521 Control Box Cable 1 910 522 Control Box Cable 2 910 523 Control Box Cable 3 910 525 Control Box Cabl...

Page 29: ...SIGMA Valve 845 6 336 001 Valve Tray Gasket 7 402 526 Grate Assembly 8 336 535 Burner Assembly NG LPG 9 402 935 Log Set 10 910 936 Pilot Assy NG 3 flame convertible top 910 947 Pilot Assy LPG 3 flame...

Page 30: ...IG34 Gas Inbuilt Fireplace PARTS LIST FACEPLATE ASSEMBLY Part Description 14 366 942 Plinth Kit 15 336 914 Faceplate Trim Complete Regular 16 336 532 Flush Screen Door Not available as a replacement...

Page 31: ...r the closest approved service agent is situated more than thirty 30 kilometres from the installation Regency is not obliged to arrange warranty repairs and travel and or additional labour charges wil...

Page 32: ...__________________________________ Register your Regency warranty online www regency fire com au Reasons to register your product online today View and modify a list of all your registered products Re...