background image

10

Regency I31-2 Gas Fireplace Inbuilt

FLUSH FRONT

INSTALLATION

1)

Install Logs before going on to the next

step. See the Log Installation instruction
sheet or page 8 in the manual.

2) Install the bottom glass trim by hooking the

trim into the lip on the firebox base. The trim
will not fit into place if the glass is installed
first.

Diagram 1

Diagram 3

Diagram 4

FACEPLATE & TRIM

INSTALLATION

1) Lay the faceplate panels flat, face down on

something soft so they don't scratch.

2) Take the top faceplate and align the holes

in it with the holes in the side panels. Using
the screws provided, attach from the top
of the panel (the holes in the top panel are
slightly larger than the holes in the side
panel to facilitate easier installation). See
diagram 1.

Diagram  2

Rear View: Trim Assembly

Diagram 5

Hint:  Don't tighten the trim to the bottom of
the faceplate side panels with the screws
provided.  See diagram 1.

3) Using the connectors provided, join the left

side trim (with the ON/OFF switch) to the top
trim. Connect the right side trim to the top
trim.See diagram 2.

4) Place the trim on the assembled faceplate

panels, aligning the wire connections from
the switches with the notch on the left side
panel.

5) Hookup the 3 Fan Switch wires to the fan

switch on the left side trim. Diagram 3.

WARNING: The 3 wires are to the
Fan and the 2 wires are to the ON/
OFF burner switch. DO NOT con-
nect to the wrong switch.

WARNING:

Ensure that the wires do NOT

touch the firebox

INSTALLATION

6) Connect the 2 burner ON/OFF switch wires

by taking the yellow and orange wires with
the female ends and connecting them to the
burner ON/OFF switch.

7) Tuck the wires into the faceplate to keep

them away from the inbuilt fireplace using
the clip provided.  Attach the clip to the rear
of the faceplate to ensure that the wires do
not touch the side of the unit.  See diagram
3.

8) The power cord should be run behind the

faceplate panel.

9) Attach the brass trim to the faceplate by

drilling a 1/8" hole through into the faceplate
using the hole in the trim as a guide.  Fasten
the trim to the faceplate panels using the
plated screws. See diagram 4.

10) Attach the faceplate panels* to the inbuilt

fireplace body using the 4 remaining black
screws.  See diagram 5.

11) Push the Regency logo plate into the two

holes in the bottom left corner of the face-
plate. See diagram 4.

Summary of Contents for I31-2

Page 1: ...ry to light any appli ance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplierfromaneighbour s phone Follow the gas sup plier sinstructions If y...

Page 2: ...s been designed to provide you with all the warmth and charm of a fireplace at the flick of a switch The model I31 2 of this series has been approved by Australian Gas Association for both safety and...

Page 3: ...Fan Maintenance 15 TroubleShooting 17 Parts List 18 Warranty Warranty 23 Page UnitDimensions 2 SafetyLabel 4 Installation For Your Safety 5 Specifications 5 Installation Checklist 5 MaterialsRequired...

Page 4: ...label that accompanies each Regency I31 2 Gas Inbuilt fireplace We have printed a copy of the contents here for your review DATA BADGE NOTE Regency units are con stantly being improved Check the labe...

Page 5: ...ustible fire place The appliance and flue should be enclosed when installed or passing through a living area where children may come in contact with it 5 Always connect this space heater to a chimney...

Page 6: ...TIONS INSTALLATION NOTE Mantel clearances for Installation into a Zero Clearance Kit are differ ent Please refer to the Zero Clear ance Kit Manual for details Mantel Clearances with Bay and Flush Louv...

Page 7: ...ED TOACHIMNEYFLUESERVINGASEPARATE SOLIDFUELBURNINGAPPLIANCE Thisapplianceisdesignedtoattachtoa100mm diameter twin skin or listed gas fuel type flue liner running the full length of the chimney A minim...

Page 8: ...cts as a safety shut off to prevent a build up of carbon monoxide If the flue is blocked or has no draw the switch will automati cally shut off the supply of gas within 5 10 minutes Tampering with the...

Page 9: ...ne end of burner to the other If there is any flame hesitation check that area for any blockage of the burner port 12 Install flush glass and optional bay glass as per instructions in this manual D 02...

Page 10: ...ace the trim on the assembled faceplate panels aligning the wire connections from the switches with the notch on the left side panel 5 Hookup the 3 Fan Switch wires to the fan switch on the left side...

Page 11: ...ion fit if the louvre needs to be adjusted bend the bracket out as shown in the diagram 3 Place the bottom of the flush glass behind the bottom glass trim 4 Secure the glass with the two glass clips a...

Page 12: ...14 GA 16 GA 18 GA 20 GA 22 GA 15 24 m 9 75 m 6 10 m 3 66 m 2 71 m WIRING CAUTION Label all wires prior to disconnectionwhen servicingcontrols Wiring errors can cause improper and dangerous operation W...

Page 13: ...the unit cooled to below a useful heat output range the fan will shut off automatically NORMAL OPERATING SOUNDS OF GAS APPLIANCES It is possible that you will hear some sounds from your gas appliance...

Page 14: ...label 1 Push in gas control knob slightly and turn clockwise to OFF Knob cannot be turned from PILOT to OFF unless knob is pushed in slightly Do not force 2 Wait five 5 minutes to clear out any gas If...

Page 15: ...arranty Clean any fingerprints off before turn ing the unit on If the top louvres start to discolour check the door gasket seal and replace if necessary LOG REPLACEMENT The unit should never be used w...

Page 16: ...of dish soap on the grommet so it will slide more easily onto the pin Check to make sure the fan is seated properly on the pins this is very important try to move the fan back and forth there should...

Page 17: ...oting continues open aeration shutter on burner Note To clean glass remove and wipe with cloth or paper towel Check gas pressure Clean out carbon spider webs lint etc from burner area Check and replac...

Page 18: ...1 Spill Switch Bracket 12 910 220 Spill Switch 13 Levelling Bolts 5 16 x 3 Hex Head 948 216 Logo Plate 918 044 Manual Masport 400 945 Brick Panel Set 33 902 255 Brick Panel Back 34 902 176 Brick Panel...

Page 19: ...Gasket Valve Heat Shield 56 Pilot Bracket 57 904 240 Burner Orifice Nat Gas 37 904 390 Burner Orifice Propane 52 58 910 424 Pilot ON OFF Extension Knob 59 910 426 Flame HI LOW Extension Knob 60 402 0...

Page 20: ...plate Trim Left Assy Regular 401 913 Faceplate Trim Compelte Oversize 141 Faceplate Side Right Oversize 142 Faceplate Top Oversize 143 Faceplate Side Left Oversize 401 524 Trims Packaged Oversize 144...

Page 21: ...0 314 P Center Glass 110 902 183 Bay Brick Panel 400 935 Bay Door Trim Set Gold 400 989 Bay Door Trim Set Steel 111 Bay Door Trim Top 112 904 196 1 Round Ceramic Magnet 113 Bay Door Trim Bottom Flush...

Page 22: ..._______________________________________________ ______________________________________________________ _______________________________________________________________ _________________________________...

Page 23: ...y Assur anceTeamcarefullyinspectseachunitthoroughlybeforeit leaves our door Regency Industries Ltd is pleased to extendthislimitedlifetimewarrantytotheoriginalpurchaser of a Regency Product The Warran...

Page 24: ...Printed in Canada...

Reviews: