HZ42E Regency Horizon™ Gas Fireplace
9
INSTALLATION
This includes:
1)
Clocking the appliance to ensure the correct
fi ring rate (rate noted on label 26,000 Btu/h
(NG), 24,500 Btu/h (LP) after burning appliance
for 15 minutes.
2)
If required, adjusting the primary air to ensure
that the fl ame does not carbon. First allow the
unit to burn for 15-20 min. to stabilize.
CAUTION: Any alteration to the product that
causes sooting or carboning that results in
damage is not the responsibility of the manu-
facturer.
INSTALLATION
CHECKLIST
1)
Locate appliance
a) Room location (Refer to "Locating Your Gas
fi replace" section)
b) Clearances to Combustibles (Refer to
"Clearances" section)
c) Mantle Clearances (Refer to "Mantel
Clearances" section)
d) Framing & Finishing Requirements (Refer
to "Framing & Finishing" section)
e) Venting Requirements (Refer to "Venting"
section)
2)
Assemble Standoffs (Refer to "Unit Assembly
Prior to Installation).
3)
Slide unit into place.
4)
Install vent (Refer to "Venting Arrangement"
sections).
5)
Make gas connections (Refer to "Gas Line
Installation section).
6)
Make electrical connections to receptacle
supplied with unit (recommended).
7)
Test the pilot (Refer to "Pilot Adjustment"
section).
8)
Test Gas Pressure (Refer to "Gas Pipe Pressure
Testing" section).
9)
Install standard and optional features. Refer to
the following sections:
a)
Glass Crystals/ Optional Ceramic
Stones
b)
Optional Firebox Base Pebbles
c) Optional
Refl ective Panels
d) Optional
Accent
Light
e) Faceplate
f)
Remote Control or Wall Thermostat
10)
Wall Mounted ON/OFF Switch:
Use the toggle wall switch supplied with the
manual package. Use of a “decor” switch causes
higher resistance which is a problem on gas
fi replaces.
11)
Final check.
Before leaving this unit with the customer, the
installer must ensure that the appliance is fi ring
correctly and
operation fully explained to
customer
.
LOCATING YOUR
GAS FIREPLACE
1)
When selecting a location for your fi replace,
ensure that the clearances are met.
2)
The appliance must be installed on a fl at, solid,
continuous surface For example a wood, metal
or concrete fl oor or in a raised (on the wall) ap-
plication. The appliance must be installed on
a metal or wood panel extending the full width
and depth of the appliance.
3)
The HZ42E Direct Vent Gas Fireplace can be
installed in a recessed position or framed out
into the room as in A, B, C and D.
See Diagram 1.
Diagram 1
A)
Flat on Wall
B)
Flat on Wall Corner
C)
Recessed into Wall/Alcove
D)
Corner
4)
This appliance is Listed for bedroom installations
using the standard Remote (millivolt thermostat
system). Some areas may have further
requirements, check local codes before
installation.
5)
The HZ42E Direct Vent Gas Fireplace
is approved for alcove installations, see
"Clearances" section for details.
6)
We recommend that you plan your installation on
paper using exact measurements for clearances
and fl oor protection before actually installing this
appliance. Have an authorized inspector, dealer,
or installer review your plans before installation.
Note: For vent terminations refer to "Exterior
Vent Termination Locations" section.