HZ42E Regency Horizon™ Gas Fireplace
53
MAINTENANCE
VALVE ASSEMBLY REPLACEMENT
1)
Turn the unit off and allow it to cool down to room temperature.
2)
Turn off the gas and power supply to the unit.
3)
Remove the faceplate by lifting it up off the glass door.
4)
Remove the glass door.
a)
Remove the 3 screws shown below at the bottom of the glass
door
.
b)
Swing the door out 45
o
from the bottom and lift up and out.
Faceplate
Glass Door
5)
Remove the pilot cover as shown below.
6)
Lift
out
fi rebox base cover.
7)
Remove three screws from locations shown below to release
burner.
Slide burner to the left to release from the orifi ce and lift out -
see inset.
8)
Remove the valve tray by undoing the 14 outer screws.
Note:
Some of the screws are not visible in Diagram below.
Note:
If optional accent lights have been installed - assure all wiring is out
of the way before removing valve assembly.