Regency Horizon™ HZ40E-10 Gas Fireplace

 | 

42

installation

OPTIONAL FAN INSTALLATION - EXISTING INSTALL

919-405

06/26/14

OPTIONAL FAN INSTALLATION - INTO EXISTING INSTALLATIONS

120 Volt AC power is needed for the fan switch and blower. The fan can be 

hard wired if desired. The receptacle box should be installed  on  the left 

hand side of the unit by a qualifi ed electrician. The neutral (wider) slot of the 

polarized receptacle should be at the top (see page 41 for wiring diagram).

Unit must be grounded at all times. Do not cut the ground terminal off 

under any circumstances.

1.

 

Shut off

 the

 

gas and power supply to the unit.

2.

  Remove the faceplate, mesh guard, enamel panels (if installed) and the 

glass door. (See the manual for detailed instructions)

3.

  Remove the inner panels - reverse of  "Inner panel Installation" in the

 

installation manual.

4.

  Remove the burner tray cover by lifting up and out as shown below.

*  Prior to removing burner - remove crystals, pebbles, spa stones and inner 

panels - if installed.

5.

  Loosen 3 screws at the back of the burner to release it.

8)

  Remove the burner by sliding it to the right - then lift out.

9)

  Remove the left access plate by undoing the 8 screws - see locations 

below. 

    

  

10)

 Remove the left access plate by undoing the 8 screws - see locations 

below. 

    

  

Location of screws on access plate

11.

 Maneouver fan through left access panel opening.

3

HZ40E

Summary of Contents for Horizon HZ40E-LP10

Page 1: ...soline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Leave the building immediately Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach you gas supplier call t...

Page 2: ...by local codes This Direct Vent System Appliance must be installed in accordance with the manufacturer s installation instructions and the Manufactured Home Construction and Safety Standard Title 24 CFR Part 3280 or the current Standard of Fire Safety Criteria for Manufactured Home Installations Sites and Communities ANSI NFPA 501A and with CAN CSA Z240 MH Mobile Home Standard in Canada This appli...

Page 3: ...e warmth and charm of a fireplace at the flick of a switch The model HZ40E has been approved by Warnock Hersey Intertek for both safety and efficiency As it also bears our own mark it promises to provide you with economy comfort and security for many trouble free years to follow Please take a moment now to acquaint yourself with these instructions and the many features of your Regency Fireplace ...

Page 4: ...ertical Terminations Rigid Pipe 4 x 6 5 8 32 Venting Arrangements Vertical Terminations 34 Unit Installation with Horizontal Termination 35 4 x 6 5 8 venting 35 Unit Installation with Horizontal Termination 36 Unit installation with Vertical Termination 37 4 x 6 5 8 venting 37 High Elevation 38 Gas Line Installation 38 Pilot Adjustment 38 Gas Pipe Pressure Testing 38 885 S I T Valve Description 38...

Page 5: ...s the correct one COPY OF SAFETY DECAL For the State of Massachusetts installation and repair must be done by a plumber or gasfitter licensed in the Commonwealth of Massachusetts FortheStateofMassachusetts flexiblecon nectorsshallnotexceed36inchesinlength For the State of Massachusetts the appli ances individual manual shut off must be a t handle type valve The State of Massachusetts requires the ...

Page 6: ...ectly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS 4 INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless upon inspec...

Page 7: ...Regency Horizon HZ40E 10 Gas Fireplace 7 7 dimensions 1092mm 972mm 522mm 902mm 318mm 388mm 15 1 4 Inner Outer Faceplate 4 Piece Faceplate Verona Surround ...

Page 8: ...er we are required by the Canadian Safety Standards and ANSI Standards to make you aware of the following CLOTHING OR OTHER FLAMMABLE MATERIAL SHOULD NOT BE PLACED ON OR NEAR THE APPLIANCE CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATURES ESPE CIALLY THE FIREPLACE GLASS AND SHOULD STAY AWAYTO AVOID BURNS OR CLOTHING IGNITION GENERAL SAFETY INFORMATION 1 The applianc...

Page 9: ...tly and operation fully explained to customer LOCATING YOUR GAS FIREPLACE 1 When selecting a location for your fireplace ensure that the clearances are met 2 The appliance must be installed on a flat solid continuous surface For example a wood metal or concrete floor or in a raised on the wall ap plication The appliance must be installed on a metal or wood panel extending the full width and depth ...

Page 10: ...ace and vent system be installed only in accordance with these instructions Clearance Dimension Measured From A Mantel Height min 17 330mm Top of Fireplace Opening B Sidewall on one side 8 203mm Side of Fireplace Opening C Ceiling room and or alcove 22 559mm Top of Fireplace Opening D Mantel Depth max 13 330mm 22 Above Fireplace Opening E Alcove Width 84 2134mm Sidewall to Sidewall Minimum F Alcov...

Page 11: ...nsure the paint that is used on the mantel and the facing is high quality or the paint may discolour MANTEL LEG CLEARANCES Combustible mantel leg clearances as per diagram Combustible Material 2 12 6 4 8 10 13 330mm Standoff Metal Stud On Edge 0 14 Non combustible Facing To Unit Base 1 25mm 22 17 27 10 20 26 Top of Fireplace Opening 559mm 4 Allowable mantel legp rojection 7 1 8 181mm 10 203mm 13 2...

Page 12: ...ox as possible The nailing strips can be adjusted back up to 3 1 4 to allow for varying thicknesses in non combustible material wall finishes Nailing Strips INSTALLATION ACCESS PANEL Theunitisequippedwitharemovableaccesspanelforpre finishinstallation of optional components this panel is located on the lower front face 1 Remove 8 screws to remove access panel 2 Easier access to gas connection with ...

Page 13: ...16 538mm C2 Vertical Vent 25 3 16 640mm Vertical rise terminating horizontal D Minimum Height to Combustibles 43 7 8 1004mm E Corner Wall Depth 61 1549mm F Corner Facing Wall Width 86 1 4 2191mm G Vent Centerline Height 36 1 4 921mm H Non combustible facing height 17 432mm I Gas Connection Opening Height 2 51mm J Gas Connection Height 4 3 16 106mm K Gas Connection Inset 8 5 16 211mm L Gas Connecti...

Page 14: ... and retighten screws 4 Attach both vertical studs and secure using 6 screws 2 at bottom 2 at top and 2 on sides as shown NOTE Ensure the flat side of the steel stud is facing the wood framing Flat side out 5 Secure horizontal steel header stud with 2 screws per side as per diagram 6 Slide the unit into position Hook up gas venting electrical and fan if purchased prior to installing the remaining ...

Page 15: ...tion box to the framing at desired location within 10 ft from fireplace 2 Feed the 12 pin connector through the opening at back of junction box 3 Connect the 12 pin connector to the back of the receiver 4 Install the Receiver in the Low Voltage Junction box 5 Insert the 4 AA type batteries in the battery compartment with the correct polarity 6 Place the slider into the cover plate 7 Put the Receiv...

Page 16: ...gh strength compound for the first coat This product can be found at any hardware store Mud must be cured as per manufacturer s recommendations 6 Prime wall for a second time for proper adhesion of paint 7 Paint walls using a high quality paint which will withstand the high temperatures being emitted from this appliance NON COMBUSTIBLE REQUIREMENTS Installation of the Receiver must be completed be...

Page 17: ...ase 4 Non combustible material ie tile slate etc may be brought up to and overlap the unit top and bottom ensuring that the maximum thickness does not go beyond the 3 1 4 as shown in the diagram below The faceplate will not be able to be mounted if finished material is beyond 3 1 4 1 Frame in the enclosure for the unit with framing material IMPORTANT The framed opening must be of non combustible m...

Page 18: ... required acceptable for a combustible material To obtain the best most durable finish around your fireplace this calls for a high level of care and attention to the preparation and finish around this appliance using only the highest quality materials able to withstand the temperatures produced By following the installation instructions in the manual exactly you will increase your chances of a dam...

Page 19: ...tended above meter regulator assembly 36 90cm a J Clearance to service regulator vent outlet 36 90cm K Clearance to non mechanical air supply inlet to building or the combustion air inlet to any other appliance 12 30cm 9 23cm L Clearance to a mechanical air supply inlet 3 91cm above if within 10 3m horizontally 72 1 8m 36 90cm b M Clearance above paved sidewalk or a paved driveway located on publi...

Page 20: ...h 3 10 Black N A N A N A 4DALB N A TC 4DLTB Adjustable Length 7 Galvanized N A N A 4D7A N A N A N A Adjustable Length 7 Black N A N A 4D7AB N A N A N A Extension Pipe 8 1 2 Galvanized 46DVA 08A N A N A N A N A N A Extension Pipe 8 1 2 Black 46DVA 08AB N A N A N A N A N A Adjustable Length 12 Galvanized N A N A 4D12A N A SV4LA12 N A Adjustable Length 12 Black N A N A 4D12A N A SV4LBA12 N A Extensio...

Page 21: ...l Termination Kit A Disc 4DT HKA 4DHTK2 4DHTKA SV SHK N A Horizontal Termination Kit B 46DVA KHA Changed Components 4DT HKB 4DHTK1 4DHTKB SV HK N A Vertical Termination Kit Disc 4DT VKC 4DHTK 4DHTK SV FK N A FPI 946 506 P Vent Guard Optional for AstroCap 946 205 Vinyl Siding Shield for Riser Vent Terminal 510 994 Rigid Pipe Adaptor Must use with all rigid piping 946 208 P Vent Guard Optional for R...

Page 22: ...ndicated in the venting arrangements diagrams refer to the following instructions 1 Remove the glass door see instructions in this manual 2 Remove the screws that hold the vent restrictor plate in place 3 Adjust the vent restrictor plate to the required vent restrictor position as per the diagrams shown 4 Once the vent restrictor plate is in the required position secure with screws VENT RESTRICTOR...

Page 23: ...ow at the flue collar when using rigid venting Note Must use optional rigid pipe adapter Part 510 994 when using Rigid Pipe Venting Systems Maintain clearances to combustibles as listed in Clearances section Horizontal vent must be supported every 3 feet Firestops are required at each floor level and whenever passing through a wall A vent guard should be used whenever the termination is lower than...

Page 24: ... 4 X 6 7 8 These venting systems in combination with the HZ40E Direct Vent Gas Fireplace has been tested and listed as a direct vent heater system by Warnock Hersey Intertek The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram in Exterior Vent Termination Locations section Regency Direct Vent Flex System Termination Kits includes all the parts...

Page 25: ...gid Pipe Adaptor in conjunction withDuraventDirect Vent SelkirkDirect Temp Ameri Vent Direct Venting ICC Excel Direct and Security Secure Vent systems Use of these systems with the Rigid Pipe adaptor is deemed acceptable and does not affect the Intertek WHI listing of components WARNING Do not combine venting components from different venting systems However use of the the AstroCapTM and FPI Riser...

Page 26: ...ng the starting 45o elbow at the flue collar when using rigid venting 2 Minimum distance between elbows is 1 ft 305mm Maintain clearances to combustibles as listed in the Clearances section Horizontal vent must be supported every 3 feet Firestops are required at each floor level and whenever passing through a wall Must use optional rigid pipe adaptor Part 510 994 when using rigid pipe vent systems...

Page 27: ...feet with minimum of 11 feet total vertical and maximum 9 feet total horizontal P l e a s e n o t e minimum 1 foot between90o elbows is required A 1 Max 1 Min 3 Max B 2 Max 3 Min 5 Max C 3 Max 5 Min 6 Max D 4 Max 7 Min 7 Max E 5 Max 9 Min 8 Max F 6 Max 11 Min 9 Max H1 H V Horizontal Venting with Two 2 90o Elbows One 90o elbow Two 45o elbows Option H V H H1 With these options maximum total pipe len...

Page 28: ...s maximum total pipe length is 28 feet with minimum of 12 feet total vertical and maximum 9 feet total horizontal P l e a s e n o t e minimum 1 foot between 90o elbows is required A 2 Min 1 Max 3 Min 4 Max B 3 Min 2 Max 4 Min 5 Max C 4 Min 3 Max 6 Min 6 Max D 5 Min 4 Max 8 Min 7 Max E 6 Min 5 Max 10 Min 8 Max F 7 Min 6 Max 12 Min 9 Max Restrictor Position Set 0 factory setting ...

Page 29: ...t American Metal Products Ameri Vent Direct Vent Security Secure Vent ICC Excel Selkirk Direct Temp AstroCapTM is a proprietary trademark of FPI Fireplace Products International Ltd Dura Vent and Direct Vent are registered and or proprietary trademarks of Simpson Dura Vent Co Inc Pipe Length Vertical Terminal Storm Collar Flashing Ceiling Firestop Adj Pipe Length Horiz Termina Wall Thim Vinyl Sidi...

Page 30: ...in the Clearances section Horizontal vent must be supported every 3 feet Firestopsarerequiredateachfloorlevelandwhenever passing through a wall Must use optional rigid pipe adaptor Part 510 994 when using rigid pipe vent systems Refer to the Vent Restrictor Position section for details on how to change the vent restrictor from the factory setting of Set 0 to Set 1 or Set 2 if required Maximum 40 f...

Page 31: ...minations Section for minimum and maximum heights Required Parts Part Description 946 529 Co linear DV Vertical Termination Cap 948 305 3 Flex 35 ft 946 563 Co Axial to Co Linear Adapter Kit whichcontainsthefollowing Co linear Flex Adapter Outer Pipe Inner Pipe Adapter 510 994 Rigid Pipe Adaptor 46DVA E45 45o Elbow Alternate Approved Caps 46DVA VC Vertical Termination Cap 46DVA VCH High Wind Cap 4...

Page 32: ...nting with Two 2 90o Elbows For additional vertical venting with 2 x 90o elbows refer to Rigid Pipe Venting Arrangements Section One 90o elbow Two 45o elbows Option V H V V1 With these options maximum total pipe length is 30 feet with minimum of 6 feet total vertical and maximum 8 feet total horizontal Please note minimum 1 foot between 90o elbows is required A 1 Min 4 Max 2 Min B 2 Min 5 Max 3 Mi...

Page 33: ...these options max total pipe length is 30 feet with min of 11 feet total vertical and max 7 feet total horizontal Please note min 1 foot between 90o elbows is required Option V H H1 V V1 A 2 Min 3 Max 4 Min B 3 Min 4 Max 6 Min C 4 Min 5 Max 7 Min D 5 Min 6 Max 8 Min E 6 Min 7 Max 9 Min F 7 Min 8 Max 10 Min Withtheseoptions max total pipelengthis30feetwithmin of 10 feet total vertical and max 8 fee...

Page 34: ...ax 35 Horizontal Distance Feet Vertical Height feet Vent Restrictor Set 2 Vent Restrictor Vent Restrictor V Vent Restrictor Set 2 Set 1 16 Max Vent 8 2 4m Min Horizontal Distance Feet Vertical Height feet 2 51mm max 35 36 1 4 921mm 35 10 7m Max Vent Restrictor Set 2 16 Max Vent Restrictor Set 1 Restrictor Set 1 Restrictor Set 2 35 Horizontal Distance Feet Vertical Height feet 2 51mm max Combined m...

Page 35: ... collar Slip the adapter over the existing inner and outer flue collar Fasten to the outer collar only with the 3 supplied screws drilling pilot holes will make this easier 4 Level the fireplace and fasten it to the framing using nails or screws through the top and side nailing strips Diagram 1 Note For best results and optimum performancewitheachapprovedventing system it is highly recommended to ...

Page 36: ...ermination cap faces up there are markings on the cap indicating which way is up This will position the termination cap with proper down slope for draining water Fasten the cap to the outer wall with the 4 supplied screws 6 Pull the centre inner and outer flex liner out enough to slip over the flue collars of the fireplace You may wish to cut the liner shorter to make it more workable Do not bend ...

Page 37: ...he fully twist locked position and sealed 5 Cut a hole in the roof centered on the small drilled hole placed in the roof in Step 2 The hole shouldbeofsufficientsizetomeettheminimum requirements for clearance to combustibles of 1 1 2 Slip the flashing under the shingles shingles should overlap half the flashing as per Diagram 3 6 Continue to assemble pipe lengths Note If an offset is necessary in t...

Page 38: ...en HIGH ELEVATION This unit is approved for altitude 0 to 4500 ft CAN1 2 17 M91 GAS LINE INSTALLATION Since some municipalities have additional local codes it is always best to consult with your local authorities and the CAN CGA B149 installation code For USA installations follow local codes and or the current National Fuel Gas Code ANSI Z223 1 When using copper or flex connectors use only approve...

Page 39: ...tem Configuration 886 GTMF Wire Diagram SureFire Switch 885 1 of 10 AC Adaptor CAUTION Labelallwirespriortodisconnection whenservicingcontrols Wiringerrorscancause improper and dangerous operation Caution Ensure that the wires do not touch any hot surfaces and are away from sharp edges ...

Page 40: ...embly through the front access panel slide all the way back to the back of the two tabs Installation Access Panel 2 Slide the fan through the front access opening push the fan all the way to the back until the fan base engages with the tabs on the bottom of the unit 5 Connect one of the black wires from the power cord to the black wire included with the fan light blue connector Connect the other e...

Page 41: ...Turn the switch on the Fan Control Module to the ON position ON is to the left The O is the off position FCM COM connector TO REMOVE THE FAN 1 Turn the power off 2 Reverse the above instructions Maintenance The sealed bearings are lubricated there is no need to lu bricate them further Extra lubricant will cause more lint and dust buildup causing the bearings to prematurely fail Regular cleaning an...

Page 42: ...off the gas and power supply to the unit 2 Remove the faceplate mesh guard enamel panels if installed and the glass door See the manual for detailed instructions 3 Remove the inner panels reverse of Inner panel Installation in the installation manual 4 Remove the burner tray cover by lifting up and out as shown below Prior to removing burner remove crystals pebbles spa stones and inner panels if i...

Page 43: ...ase with 2 screws Note the right access panel was removed to allow easier access to the right side screw 14 Secure the ground wire from the fan assembly and the power cord to the ground lug located on the back left near the fan 15 The fan control module supplied with the fan kit secures to the side access panel Remove 2 top screws and loosen 2 bottom screws to remove the side access pane 17 Plug i...

Page 44: ...White Black Black Ground Fan Fan Proflame System Configuration 886 GTMF Wire Diagram SureFire Switch 885 CAUTION Labelallwirespriortodisconnection whenservicingcontrols Wiringerrorscancause improper and dangerous operation Caution Ensure that the wires do not touch any hot surfaces and are away from sharp edges WIRING DIAGRAM WITH OPTIONAL FAN ...

Page 45: ...Use care not to scratch or mar the panel on the pilot shield Final Install 3 Remove installed factory panels Loosen 2 screws do not remove on panel clip securing side panel Slide panel clip down away from screws Remove side panel Handling Instructions Black Enamel Panels Black Enamel panels must be inspected for scratches and dimples prior to installation All claims to be recorded at this time Cla...

Page 46: ...ds 30 Ceramic Stones or 2 lb Bead 25 Volcanic Stones NOTE Glass Crystals are not supplied with the unit Must purchase separately see quantities above OPTIONAL PEBBLES GLASS CRYSTAL INSTALLATION FOR FIREBOX BASE AROUND BURNER Firebox Around Burner Packages Unit Glass Crystals Fire Beads Pebbles HZ40E 5 lbs 5 lbs 2 packages 6 x bags pebbles There are 2 optional packages to choose from to cover the f...

Page 47: ...rature 2 Remove flush glass door see manual 3 Carefully remove the logs from the packaging and unwrap them The logs are fragile handle with care never force into position 4 Ensure glass crystals are installed on the burner HZ54E 2lbs HZ40E 1 5lbs 5 HZ54E only Remove existing pilot hood replace with pilot hood provided with log set HZ54E existing Pilot Hood HZ54E new Pilot Hood HZ40E log placement ...

Page 48: ...og piece on firebox floor as shown 16 Place Right Log piece on firebox floor as shown 17 If desired install additional crystals on firebox floor in and around installed logs 18 Install lava embers spread evenly over glass HZ54E shown Left Log 2 positioned to match template profile HZ54E shown Completed Install HZ40E shown Completed Install HZ54E shown Left Cross Log 4 positioned to match template p...

Page 49: ...door simply hook the top door flange onto the top of the unit and swing the door towards the unit Diagram 1 Note Be careful that the glass gasket does not roll up there must be a gap between the gasket and the door lip to ensure that the door sits securely on the unit See Diagram 2 Diagram 2 Diagram 3 Diagram 1 2 With the door in proper position secure with 2 screws in locations shown in Diagram 3...

Page 50: ...l screen into inner door trim 3 Secure screen by bending down the 6 tabs as shown 4 Hook the outer door frame 3 and mesh screen 2 assembly over the inner door frame 1 5 Bend the center tab up and secure with a screw to attach the outer frame mesh assembly to the inner door frame 6 Attach the completed assembly to the glass frame on the fireplace 7 Secure the assembly with screws on each side as sh...

Page 51: ... HZ40E 4 PC FACEPLATE INSTALLATION Important 1 2 gap required between faceplate and finished wall when using part 256 924 256 926 256 927 4 pc faceplate 1 If installing optional mesh glass guard See optional Mesh Glass Guard installation instructions 2 Install brackets onto the back of the faceplate 3 screws for each bracket in locations shown below Hook bracket over these tabs Final Install 1 4 1...

Page 52: ... brackets into the mounting slots at the side of the firebox as shown below It is recommended that you use the first mounting slot the one closest to the door frame overlay out of the 3 so that the faceplate and door frame overlay are flush with one another NOTE There are 3 mounting slots available this is to accommodate any finishing that protrudes slightly beyond the faceplate Tab on Faceplate B...

Page 53: ...fog the glass This condensation is normal and will disappear in a few minutes as the glass heats up DONOTATTEMPTTOCLEANTHEGLASS WHILE IT IS STILL HOT DO NOT BURN THE UNIT WITHOUT THE GLASS DOOR IN PLACE FIRST FIRE NORMAL OPERATING SOUNDS OF GAS APPLIANCES It is possible that you will hear some sounds from your gas appliance This is perfectly normal due to the fact that there are various gauges and...

Page 54: ... approximately 60 seconds If there is no flame ignition rectification the board will stop sparking for approximately 35 seconds After wait time the board will start second try for ignition by sparking for approximately 60 seconds If there is still no positive ignition the board will go into lock out The system will need to be reset as follows a Turn the system off using ON OFF switch or press ON O...

Page 55: ...r service agency or gas supplier AVERTISSEMENT Quiconque ne respecte pas à la lettre les instructions dans la présente notice risquede déclencher un incendie ou une explosion entraînant des dommages des blessures ou la mort Une installation d ajustement de modification de service ou d entretien peut provoquer des blessures ou des dommages matériels Reportez vous au manuel du propriétaire de l info...

Page 56: ...ing damaged or broken glass WARNING Do not operate the appliance with the glass panels removed cracked or broken Replacement of the glass panels should be done by a licensed or qualified service person GLASS DOOR Your Regency fireplace is supplied with high temperature 5mm Ceramic glass If your glass requires cleaning we recommend using an approved glass cleaner available at all authorized dealers...

Page 57: ...he faceplate or door frame see instruction in this manual 5 Remove the inner panels reverse of Inner panel Installation in this manual 6 Remove the burner tray cover by lifting up and out as shown below Prior to removing burner remove crystals pebbles spa stones and inner panels if installed 7 Remove 3 screws on the burner to release it locations shown below 8 Remove the burner by sliding it to th...

Page 58: ...7 911 006 Pilot Assembly IPI NG 911 007 Pilot Assembly IPI LP 8 258 574E P Valve Assembly HZ40E NG SIT 258 576E P Valve Assembly HZ40E LP SIT 9 910 157 P Replacement Fan Dual Blower 10 258 013 Mesh Barrier Part Description 911 032 10 ft wiring harness 910 572 Wall switch receiver 910 576 Receiver wall plate white 911 037 Flame Sensor 911 038 Flame electrode 910 100 Pilot orifice NG 910 101 Pilot o...

Page 59: ...oor Frame Black 258 967 Inner Door Frame Stainless 256 951 Verona Glass Surround Pure Black 256 955 VeronaGlassSurroundChocolateBrown 258 917 Fan Kit 258 013 Mesh Guard 256 930 P Log Set Part Description 5 pound bag of glass crystals 946 775 Black Reflective Crystals 946 776 Copper Crystals 946 777 Starfire Crystals 946 672 Natural River Pebbles 946 674 Ceramic Spa Stones 946 710 Volcanic Stones S...

Page 60: ...60 Regency Horizon HZ40E 10 Gas Fireplace 60 notes ...

Page 61: ...Regency Horizon HZ40E 10 Gas Fireplace 61 61 notes ...

Page 62: ...62 Regency Horizon HZ40E 10 Gas Fireplace 62 notes ...

Page 63: ...eturned to the distributor or agent Transportation Prepaid if requested Porcelain Enamel Absolute perfection is either guaranteed nor commercially possible Any chips must be reported and inspected by an authorized dealer within three days of installation Reported damage after this time will be subject to rejection It is the general practice of Regency to charge for larger higher priced replacement...

Page 64: ..._________________________________________________ Phone ____________________________________________________________ Date Installed _______________________________________________________ Serial No ___________________________________________________________ Register your Regency warranty online www regency fire com Reasons to register your product online today View and modify a list of all your re...

Reviews: