background image

32

Regency GFI300L Gas Fireplace Inbuilt

PARTS LIST

FACEPLATE ASSEMBLY

 

 

 

 

                                     

BURNER AND PILOT ASSEMBLY

 

 

 

 

                                     

      

 

 

 

 

 

                  

Part #

Description

45

940-423/P

Tempered Glass

46

948-066

Glass Standoff (ea)

      

 

 

 

 

 

                  

Part #

Description

47

911-146

Pilot Assy NG

911-157

Pilot Assy LP

45

47

46

Summary of Contents for GFI300LLP-R

Page 1: ...al switch donotuseanyphone in your building Immediately call your gas supplier from a neighbour s phone Follow the gas sup plier s instructions If you cannot reach your gas supplier call the fire depart ment WARNING Improperinstallation adjustment alteration service or maintenance can cause injury or property damage Refer to this manual For assistanceoradditionalinformationconsult an authorised in...

Page 2: ...provide you with all the warmth and charm of a fireplace at the flick of a switch The model GFI300L of this series has been approved by Australian Gas Association for both safety and efficiency As it also bears our own mark it promises to provide you with economy comfort and security for many trouble free years to follow Please take a moment now to acquaint yourself with these instructions and the...

Page 3: ...n 14 Aeration Adjustment 14 Conversion Kit to LP or ULPG 15 Optional Enamel panels 17 Log Set installation 18 Glass door installation 20 Faceplate trim installation 21 Primary Glass guard installation 22 Optional mesh guard installation 22 Wiring 23 Operating Instructions Operating Instructions 24 Lighting Instructions 24 Shutdown Instructions 24 First Fire 24 Remote Control 24 Summary Of Controls...

Page 4: ...n the unit and if there is a difference the label on the unit is the correct one DO NO T DO NO T DO NO T DO NO T DO NO T DO NO T OPERATE THIS APPLIANCE BEFORE READING THE INSTRUCTIONS BOOKLET PLACE ARTICLES ON OR AGAINST THIS APPLIANCE STORE CHEMICALS OR FLAMMABLE MATERIALS SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHILE IN OPERATION OPERATE WITH PANELS COVERS OR GUARDS REMOVED FROM THIS AP...

Page 5: ...Regency GFI300L Gas Fireplace Inbuilt 5 INSTALLATION UNIT DIMENSIONS 236mm 362mm 584mm 288 mm 38mm 908mm 682mm 683 mm 362 mm 100 mm flue ...

Page 6: ...ments burners and circulating airpassagewaysoftheappliancebekeptclean and free from excessive lint from carpeting 4 Seegeneralconstructionandassemblyinstruc tions This appliance may only be installed in a flued non combustiblefireplace Theappliance and flue should be enclosed when installed or passing through a living area where children may come in contact with it 5 Always connect this space heat...

Page 7: ...m cavity requirements are to be maintained to ensure safe and proper operation of the appliance Ensure all construction conforms to local building codes MASONRY INSTALLATION The minimum fireplace dimensions for a masonry installation are shown in the diagrams below 367mm 590mm 688mm 367mm 238mm125mm ...

Page 8: ...LES The minimum fireplace clearances for the Regency gas space heater are shown in the following diagrams From Unit Sides A 464 mm Ceiling B 860 mm Mantle C see Mantel Clearances Min Alcove Width E 1924 mm Max Alcove Depth F 914 mm D E C A B F 4 102mm Allowable mantel leg projection 7 1 8 181mm 10 203mm 13 279mm 1 5 38mm MANTEL LEG 7 178mm MANTEL LEG CLEARANCES Combustible mantel leg clearances as...

Page 9: ...orner Wall Depth 39 9 16 1006mm F Corner Facing Wall Width 56 1422mm I Gas Connection Opening Height 2 51mm J Gas Connection Height 2 5 8 67mm K Gas Connection Inset 3 11 16 99mm L Gas Connection Opening Width 2 1 2 64mm A B C Timber Studs F E I J K L Finished Floor C C Note All framing may be of wood construction OPTIONAL MOCK FIREPLACE ZERO CLEARANCE DIMENSIONS NO MASONRY CHIMNEY ...

Page 10: ...nd bend into the correct shape Bend up at the bend lines until the screw holes in the standoff and the pre punched screw holes on the unit line up 3 Install left and right nailing brackets Remove existing screws from the outside of the unit line up bracket with holes in the unit and secure with 2 removed screws See framing clearance dimensions in the installation manual Mock Fireplace zero clearan...

Page 11: ...ot have to be completely enclosed in a chase You must maintain clearances from the vent to combustible materials See Clearances section Combustible materials can be laid against the side and back standoffs and the stove base 3 Finishing material may be brought to the side and top of the framing do not bring combustible material beyond the framed opening This is both for safety and servicing of the...

Page 12: ...the glass is removed or opened for servicing it must be replaced and closed prior to operating the appliance The glass must be fixed in the door when operating SPECIFICATIONS NG LP ULPG Injector Size 40 53 55 Input Rating Max 30 mj Max 27 mj Max 21 mj Min 20mj Min 22 mj Min 17 mj Manifold Pressure 0 9 kPa 2 3 kPa 2 3 kPa Aeration Setting 5 mm 13 mm full open GAS CONNECTION WARNING Only persons lic...

Page 13: ...e operation and must be installed with provisions for adequate combustion and ventilation air avail able to the room in which it is to be operating Air for combustion is drawn in through the front of the unit therefore the front of the unit must be kept DRAFT DIVERTER CONNECTION 1 Attach the flue to the flue collar on the detach able draft diverter The flue collar of the appli ance will fit inside...

Page 14: ...n the safety label 6 When finished reading manometer turn off the unit disconnect the hose and tighten the screw clockwise with a 1 8 flat screwdriver Note Screw should be snug but do not over tighten Note If you have an incorrect flame pattern contactyourRegency dealerforfurther instructions Incorrectflamepatternwillhavesmall probably yellow flames not coming into proper contact with the rear bur...

Page 15: ...e logs See log section in this manual 6 Remove the panels See panel section in this manual 7 Remove the log tray by removing 2 screws in locations shown below 8 Lift log tray up and out to remove 9 Remove burner loosen screw on left side remove screw from right side slide to the right and lift up and out to remove and discard Loosen Remove 10 Remove 2 screws in location shown below to remove front...

Page 16: ...t taking care not to obstruct the breather orifice of the pres sure Put back the modulator plastic cap WARNING To ensure the correct operation of the modulator it is necessary that the plastic cap A is returned to its original loca tion 23 Reverse Steps 10 4 3 2 and 1 24 At the end of all setting and adjustment operations check electrical installation and gas leaks 24 Check operation of flame cont...

Page 17: ...flat against the back of the unit 4 Before installing the side panels loosen the screws for the tabs enough so that you can slide the tabs on to the screws easily but that the tabs are secure For the location of the side tab screws see diagram 2 5 Slide the side panels into position and tighten the screw to secure the tab repeat to install panel on opposite side of unit 6 Reinstall glass door see ...

Page 18: ...burner as shown below 2 1 2 Locate pin hole on Log 2 and line up with pin on the right side of the burner The left end of Log 2 will rest against a tab in location shown below 3 Place Log 3 on the centre of the burner rest the log against the centre tabs Logs 1 fits over pins behind burner Logs 2 fits over pin on left side rests against tab on right Logs 2 in position Logs 3 place in centre of bur...

Page 19: ...g 5 fits into the notch in Log 1 The other end of the Log 5 will rest on the burner tray covering the hole as shown below 6 Place Log 6 across Logs 1 and 4 The top part of Log 6 fits into the notch on the left hand side of Log 1 The bottom end of Log 6 should sit so it covers a screw on the burner tray 7 Place Log 7 on the left hand side of the burner Log 7 will sit in a notch on Log 6 and the bot...

Page 20: ...g 7 in position Rest Log 9 upright against Log 2 as shown below 9 2 Final Install Log 9 rests on Log 2 INSTALLATION GLASS DOOR INSTALLATION 1 Lift glass door and slot keyhole in glass door over screw installed in unit body 2 Once in position slide glass door down and secure with 2 screws at the bottom of the door as shown below and tighten the top 2 two screws 3 To remove reverse steps ...

Page 21: ...ure Faceplate with 2 screws in locations shown below 2 Lift Faceplate over brackets on top of unit hook faceplate over brackets and lower gently 4 Install lower access panel slide the 2 tabs located on the top of the ac cess panel into position and secure with 2 screws as shown below 5 Proceed to glass or optional mesh guard installation ...

Page 22: ...ncy GFI300L Gas Fireplace Inbuilt INSTALLATION PRIMARY GLASS GUARD INSTALLATION OPTIONAL MESH GUARD INSTALLATION 1 Insert silicone grips into all four 4 glass retaining brackets 2 Slide glass through brackets ...

Page 23: ...acesandareawayfrom sharp edges SIT 204 IGNITION MODULE SIGMA 845 GND GND JUMPER 2 12 1 10 11 9 RED BLUE GREEN BROWN 4 5 3 2 1 YELLOW 3 YELLOW BLUE GND BROWN LOW SPEED WHITE RED BLACK FAN 5 3 4 BROWN VIOLET BLUE RED 1 3 2 4 WHITE YELLOW VIOLET BLACK 5 6 1 2 BROWN BLUE VIOLET RED BLACK WHITE YELLOW VIOLET ORANGE ORANGE MODULATING 7 8 6 5 4 3 VALVE RESET SWITCH NC BLACK BLACK 2 1 COIL MODULE SPARK MO...

Page 24: ...theappliance is lit it may cause condensation and fog the glass This condensation is normal and will disappear in a few minutes as the glass heats up DO NOT ATTEMPT TO CLEAN THE GLASS WHILE IT IS STILL HOT DO NOT BURN THE APPLIANCE WITH OUT THE GLASS FRONT IN PLACE FAN OPERATION Set the fan speed on the control panel to adjust to the desired speed Pressing and releasing the plus FAN button will ch...

Page 25: ...round the appliance DUHD IRU JDV H VXUH WR VPHOO QH W WR WKH ÀRRU EHFDXVH some gas is heavier than air and will settle on the ÀRRU WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electric switch do not use DQ SKRQH LQ RXU EXLOGLQJ Immediately call your gas supplier from a QHLJKERUV SKRQH ROORZ WKH JDV VXSSOLHU V instructions I RX FDQQRW UHDFK RXU JDV VXSSOLHU FDOO WK...

Page 26: ...E Conduct an inspection of the venting system semi annually Recommendedareastoinspectasfollows 1 ChecktheVentingSystemforcorrosioninareas that are exposed to the elements These will appear as rust spots or streaks and in extreme cases holes These components should be replaced immediately 2 Remove the Cap and shine a flashlight down theVent Removeanybirdnests orotherforeign material 3 Checkforevide...

Page 27: ...l 5 Remove the logs See log section in this manual 6 Remove the panels See panel section in this manual 7 Remove the log tray by removing 2 screws in locations shown below 8 Lift log tray up and out to remove 9 Remove burner loosen screw on left side remove screw from right side slide to the right and lift up and out to remove 10 Remove 2 screws in location shown below to remove front bracket Loos...

Page 28: ...sure all power is turned off 1 Follow steps 1 11 on previous page to access pressure switch 2 Disconnect wire leads and tubing on the switch NOTE It is important to label wires and hose connections to ensure the new switch is hooked up in the same manner 3 Remove the two screws on the mounting bracket 4 Slide switch out to the left side 5 Remove switch and replace 6 Reverse steps to complete insta...

Page 29: ...ve and check static pressure If OK turn unit on and check there is no significant drop in the pressure Unit sparks pilot ignites spark continues for 25 seconds even after pilot flame is present This can be caused by incorrect polarity Check that wall socket to appliance has correct polarity If an extension lead is fitted check polarity of the lead Check the polarity of the supply lead to the appli...

Page 30: ...Assembly Gasket 904 345 Burner Orifice 53 LPG 904 575 Burner Orifice 55 ULPG 911 145 Manual Switch Not shown Not a replacement part Part Description 23 904 553 8 x 1 2 PAN HD PHILLIPS 24 904 926 SCREW 10 32 x 5 8 PAN HEAD 25 904 122 RIVET 1 8 x 1 8 STEEL OPEN END 26 904 578 10 24 x 0 750 PAN HEAD PHILLIPS 28 626 525 Burner Assembly NG 29 626 530 Burner Assembly LP 32 910 155 P Replacement Fan Moto...

Page 31: ...Regency GFI300L Gas Fireplace Inbuilt 31 PARTS LIST MAIN ASSEMBLY 27 9 6 21 24 26 11 4 5 12 16 17 37 1 2 38 28 35 32 33 10 34 ...

Page 32: ...s Fireplace Inbuilt PARTS LIST FACEPLATE ASSEMBLY BURNER AND PILOT ASSEMBLY Part Description 45 940 423 P Tempered Glass 46 948 066 Glass Standoff ea Part Description 47 911 146 Pilot Assy NG 911 157 Pilot Assy LP 45 47 46 ...

Page 33: ...Regency GFI300L Gas Fireplace Inbuilt 33 NOTES ...

Page 34: ...34 Regency GFI300L Gas Fireplace Inbuilt NOTES ...

Page 35: ...e Covered under the agreement are the following components Combustion chamber heat exchanger burner tubes logs embers glass thermal breakage and all gold plating against defective manufacture The above will be covered for parts and labour for the first five years and parts only thereafter Electrical components such as fans switches wiring thermodiscs remote control thermopiles thermocouples and ga...

Page 36: ...alled ______________________________________________________ Serial No __________________________________________________________ Register your Regency warranty online www regency fire com au Reasons to register your product online today View and modify a list of all your registered products Request automatic email notification of new product updates Stay informed about the current promotions even...

Reviews: