background image

 Regency

®

 E18 Gas Fireplace Insert

27

INSTALLATION

MODIFICATION OF MONTIGO 36SR

1.

  Turn off and Disconnect Gas and Power.

2.

  Remove Top and Bottom Louvers.

3.

  Remove Glass Doors and Screen Mesh (See Diagram 8.1).

Diagram 8.1

Diagram 8.4

Diagram 8.3

Diagram 8.5

Diagram 8.2

4

.  Remove Logs and Sand from Sand Pan.

5.

  Remove Top Rail securing the Bifold Doors (See Diagram 8.2).

6.

  Remove Air Inlet Strip (See Diagram 8.3).

7.

  Remove Brick Liner Panels (See Diagram 8.4).

8.

  Unscrew and Remove Trim Around Sand Pan (See Diagram 8.5).

Summary of Contents for E18

Page 1: ...ight any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department FPI FIREPLACE PRODUCTS INTERNATIONAL LTD 6988 Venture St Delta BC Canada V4G 1H4 919 180d MODELS E18 NG Natural Gas E18 LP Propane E18 Gas Insert ...

Page 2: ...ou with all the warmth and charm of a fireplace at the flick of a switch The models E18 NG and E18 LP of this series have been approved by Warnock Hersey for safety As it also bears our own mark it promises to provide you with economy comfort and security for many trouble free years to follow Please take a moment now to acquaint yourself with these instructions and the many features of your Regenc...

Page 3: ...Regency E18 Gas Fireplace Insert 3 DIMENSIONS UNIT DIMENSIONS PP PP PP PP PP PP PP PP PP PP PP Diagram 1 1 ...

Page 4: ... Installation 47 Log Tray Installation 48 Log Set Installation 48 Optional Log Set Installation 50 Glass Door Installation 52 Safety Screen Replacement 52 Drafthood check 53 Remote Control 53 Wall Switch 53 Wall Thermostat 53 Safety Switches 54 Operation Controls 54 Fireplace Controls 54 Final Check 55 Operating Instructions 55 Lighting Procedure 55 Shutdown Procedure 55 Pilot Adjustment 56 Copy o...

Page 5: ...market permanently located manufactured mobile home where not prohibited by local codes See owner s manual for details WARNING This fireplace has been converted for use with a gas fireplace insert only and cannot be used for burning wood or solid fuels unless all original parts have been replaced and the fireplace re approved by the authority having jurisdiction Installer l appareil selon les code...

Page 6: ...y in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS 4 INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless upon inspection...

Page 7: ...absence of local codes with the current NationalElectricalCode ANSI NFPA70orCSA C22 1 Canadian Electrical Code 3 See general construction and assembly in structions The appliance and vent should be enclosed 4 This appliance must be connected to the speci fied vent and termination cap to the outside of the building envelope Never vent to another room or inside a building Make sure that the vent is ...

Page 8: ...r flue spillage Refer to the Test for Flue Spillage section 7 Installstandardandoptionalfeatures Refer to the following sections where applicable a Brick or Enamel Panels b Faceplate Trim c Circulation Fan d Remote Control e Wall Switch f Wall Thermostat 8 Final check Refer to the Final Check section Before leaving this unit with the customer the installer must ensure that the appliance is firing ...

Page 9: ... local codes and or the current National Fuel Gas Code ANSI Z223 1 When using copper or flex connectors use only approvedfittings Alwaysprovideaunionsothat gas lines can be easily disconnected for burner or fan servicing Flare nuts for copper lines and flex connectors are usually considered to meet this requirement Important Always check for gas leaks with a soap and water solution or gas leak det...

Page 10: ...scwhichwillpreventtheblower from operating until the unit reaches the correct temperature Height Depth Width 23 3 8 12 1 2 32 MINIMUM FIREPLACE OPENING FOR MASONRY AND FACTORY BUILT FIREPLACES The minimum fireplace opening for this Regency gas insert are listed below VENTING THE APPLIANCE MUST NOT BE CONNECTED TO A CHIMNEY FLUE SERVING A SEPARATE SOLID FUEL BURNING APPLIANCE Thisapplianceisdesigne...

Page 11: ...a combustible side wall is 6 229mm The minimum clearance from the bottom edge of the front trim above the window to a combustible mantel is 17 7 8 454 mm The minimum height from bottom edge of the front trim above the window to the ceiling is 37 7 8 962 mm Note A non combustible mantel and framing may be installed at a closer tolerance if the framing is made of metal studs covered with a non combu...

Page 12: ...a minimum of 8 feet of vertical pipe and you may use up to a maximum of 6 feet of horizontal pipe with two 9 degree elbows The venting must terminate vertically with an approved B Vent Cap All horizontal runs must maintain a 1 4 of rise for every foot of horizontal run PP 0LQ PP 0LQ PP PP 0LQ PP 0LQ PP 0LQ KDVH HSWK HDGHU HLJKW HLOLQJ HLJKW QVHUW HUR OHDUDQFH LW 6XUURXQG UDPLQJ 7 SLFDO UDPLQJ 1 Wh...

Page 13: ...quirements for ZC kit noted below Remove existing wood header and replace with supplied steel stud Supplied stud will be longer than framed opening adjust to fit before installing Additional adjustments to framed opening may be required 11 Bend ZC kit side pieces as shown and remove knockouts if required before installation Bend to 90º secure in place to supplied steel stud Remove knockouts if req...

Page 14: ...nside base section 15 Install the back section of the ZC kit Fasten bottom back and side sections with 904 576 screws provided 16 Install the remaining side of the ZC kit Bring the electrical box to the inside of the ZC kit Fasten side and back sections with 904 576 screws provided 17 Assemble ZC kit surround with 8 904 897 screws provided in loca tions shown below 18 Securesurroundandoutsideflang...

Page 15: ...framed opening 20 Separate E18 inner and outer fireboxes see E18 installation manual for details 21 Set E18 outside firebox legs as shown below 23 The top panel of the ZC surround may be removed to ease the in stallation of the venting reinstall top panel after venting is installed Extra venting may be required to get inside the ZC box A 4 flex can be used if required not provided if inside ZC she...

Page 16: ...16 Regency E18 Gas Fireplace Insert INSTALLATION 25 Install lower trim piece with 2 904 897 screws to the bottom of the ZC surround before installing faceplate ...

Page 17: ... ZC box it is being intalled in See details in manual 11 Measure and align outer firebox as per manual secure each corner using self tapping screws 12 Install inner firebox into outer firebox ensure draft hood bottom fits on top of draft hood slides left side right side and rear 13 Secure inner firebox 2 screws on top left and right side using existing holes 14 Secure inner firebox on bottom insid...

Page 18: ...ve 4 Phillips crews 2 per side located on the bottom base of the firebox Place screws and panel brackets aside for reinstallation 6 Carefully lift out the inner firebox and set aside until required Use caution with sleeved wires on the left side place inner firebox aside 7 Outer firebox shell is ready for installation Refer to particular approved appliance in which the E18 is being installed into ...

Page 19: ...ove Burner Assembly See Diagram 5 1 Diagram 5 1 Diagram 5 2 Grind corners Diagram 5 3 Diagram 5 4 Modidfied edges must be flush to allow proper seating of the E18 outer shell 7 Cut the Front Bar Out on the left and right Sides of the Firebox See Diagram 5 2 Grind the corners smooth on the left side to reduce the risk of wires being cut Alternate method is to cut front bar in the center and break o...

Page 20: ... PP PP PP 3 LUHER HJ Right side shown PP PP 3 LUHER QVHUW 7 6 GDSWRU 3ODWH IDVWHQHU VHWWLQJ OH GDSWRU HQJWK ROODU 3ODWH 6HWWLQJ 9HQW SRVLWLRQ 1 Loosen 2 x Phillips screws on both right and left legs 2 See above diagram below for required leg setting 3 Install with supplied Phillips screws to pre punched holes and tighten previous screws that were loosened in Step 1 4 Keep left side leg loose until...

Page 21: ...d Disconnect Gas 2 Remove Top and Bottom Louvers 3 Remove Glass Door See Diagram 6 1 Diagram 6 1 Diagram 6 3 Diagram 6 4 Diagram 6 5 Diagram 6 2 4 Remove Side Filler Plates and Front Hood See Diagram 6 2 5 Remove Front Bar See Diagram 6 3 6 Remove Primary and Secondary Limit Switches See Diagram 6 4 7 Remove Insert See Diagram 6 5 ...

Page 22: ...ting of the E18 outerbox 9 Remove Fan See Diagram 6 7 10 Remove the leftover ends of the front bar on the Left and Right sides so that they are flush with the sides of the firebox See Diagram 6 8 E18 INSTALL SPECIFICATIONS See Installation of E18 into Existing Units for General Installation Guidance This install of the E18 uses Vent Connection Type A The Length of 4 Flex needed is approximately 4 ...

Page 23: ...ifold Doors Diagram 7 1 Diagram 7 4 Diagram 7 3 Diagram 7 5 Diagram 7 2 4 Remove Logs and Sand from Sand Pan 5 Remove Front Bar See Diagram 7 2 6 Disconnect Pilot Gas Line and Pilot Thermopile from the Valve Disconnect Thermostat wires from valve 7 Disconnect Valve from the Main Burner Line See Diagram 7 3 8 Unscrew left and right side nuts under the firebox holding down the Sand Pan see Diagram 7...

Page 24: ...gram 7 11 and 7 12 9 Remove Sand Pan and Pilot Assembly 10 Cut out the Bottom of the Firebox See Diagram 7 7 Cut must be clean with Max 1 4 of material left 11 Cut the Sides of the Top Face See Diagram 7 8 Diagram 7 6 Diagram 7 9 Diagram 7 10 Diagram 7 7 Diagram 7 8 Diagram 7 12 Diagram 7 11 12 Bend Top Face Down See Diagram 7 9 13 Measure and draw a line 1 the bottom of the exhaust collar See Dia...

Page 25: ...place Insert 25 INSTALLATION Diagram 7 13 Diagram 7 14 Modified edges must be flush to allow proper seating of the E18 outerbox 14 Bend the Louver Mounts Flat See Diagram 7 13 15 Final Firebox Should Look Like Diagram 7 14 ...

Page 26: ...ength of 4 Flex needed is 2 5 8 semi expanded Secure flue adapter top plate to under side of existing firebox using 4 self taping screws 28 F 28 F2 INSTALLATION SPECIFICATIONS 1 Loosen 2 x philips screws on both right and left legs 2 See above diagram below for required leg setting 3 Install with supplied phillips screws to prepunched holes and tighten previous screws that were loos ened in Step 1...

Page 27: ...3 Remove Glass Doors and Screen Mesh See Diagram 8 1 Diagram 8 1 Diagram 8 4 Diagram 8 3 Diagram 8 5 Diagram 8 2 4 Remove Logs and Sand from Sand Pan 5 Remove Top Rail securing the Bifold Doors See Diagram 8 2 6 Remove Air Inlet Strip See Diagram 8 3 7 Remove Brick Liner Panels See Diagram 8 4 8 Unscrew and Remove Trim Around Sand Pan See Diagram 8 5 ...

Page 28: ... Gas Line 11 Remove Plate On the Bottom of the Firebox where Pilot Enters See Diagram 8 6 12 Unscrew Left and Right Nuts Underneath the Firebox Holding Down the Sand Pan See Diagram 8 7 13 Remove Sand Pan and Pilot Assembly 14 Unscrew the Bottom of the Firebox See Diagram 8 8 15 Unscrew the Firebox Top Front Flange making sure to place the Top Left and right corner screws back in See Diagram 8 9 a...

Page 29: ... INSTALLATION 16 Remove Louver Supports in all 4 corners of the Appliance See Diagram 8 11 Diagram 8 11 Diagram 8 12 Modified edges must be flush to allow proper seating of the E18 outerbox 17 Final firebox should look like Diagram 8 12 ...

Page 30: ...HU VHWWLQJ PP HJ 6HWWLQJ 2XWHU 6KHOO 3RVLWLRQ OH GDSWRU HQJWK ROODU 3ODWH 6HWWLQJ 9HQW SRVLWLRQ PP PP PP 65 LUHER HJ K Right side shown Set to this hole 1 Loosen 2 x philips screws on both right and left legs 2 See above diagram below for required leg setting 3 Install with supplied phillips screws to prepunched holes and tighten previous screws that were loosened in Step 1 4 Keep left side leg lo...

Page 31: ... See Diagram 9 1 3 Remove the Bottom of the Firebox and Sand Pan in one assem bly See Diagram 9 2 4 Unscrew and Remove Front Inner Baffle See Diagram 9 3 5 Cut the Sides of the Rear Inner Baffle at the Back of the Firebox See Diagram 9 4 6 Bend the Inner Rear Baffle up so it is flush with the back of the Firebox or cut off the Baffle if it will not bend flat with the back of the Firebox ...

Page 32: ... 7 Cut The Top Front Flange of the Firebox See Diagram 9 5 8 Cut off support tab at the top of the firebox and final firebox should look like Diagram 9 6 Diagram 9 5 Diagram 9 6 Modified edges must be flush to allow proper seating of the E18 outerbox ...

Page 33: ...s on both right and left legs 2 See above diagram below for required leg setting 3 Install with supplied phillips screws to prepunched holes and tighten previ ous screws that were loosened in Step 1 4 Keep left side leg loose until outer firebox is in position in ZC box to allow adjustment of gas line Firesong 22N faceplate is an outside fit if the front metal face of the 220N is covered with ston...

Page 34: ... Diagram 1 3 Diagram 1 7 Diagram 1 4 Diagram 1 5 Diagram 1 6 3 Remove Lower Trim piece and Bottom Panel See Diagram 1 2 4 Remove Top Rail securing Mesh See Diagram 1 3 5 Shut off and disconnect gas line from valve 6 Unscrew and Remove Trim Around Sand Pan See Diagram 1 4 7 Remove Logs See Diagram 1 5 8 Remove screw on right side to remove sand pan and base See Diagram 1 6 9 Remove Valve 10 Make 2 ...

Page 35: ... of firebox 12 Cut out mid section of Firesong firebox See Diagram 1 9 Cut off bar at back of firebox 14 Cut out right side of existing Firesong firebox See Diagrams1 11 1 12 and 1 13 Left and right cutout begins on front face see diagram 1 12 IMPORTANT Cut out Firesong firebox and install support one side at a time Back bar 13 Remove 6 screws one at a time and replace with pan head wafer screws i...

Page 36: ...ting plate must be retained and affixed to the unit See Diagram 1 14 and 1 15 Diagram 1 13 Diagram 1 15 Firesong decal affixed Diagram 1 14 18 Final modified firebox should look like Diagram 1 15 NOTE Shown with flue collar and 6 flex installed IMPORTANT NOTE Separate inner and outer firebox on E18 see instructions in this manual Before installing outer firebox lay on a flat surface and trim off 1...

Page 37: ...the height of the outer firebox installed is shown below Right side shown PP PP 3 LUHER QVHUW 7 6 GDSWRU 3ODWH IDVWHQHU VHWWLQJ OH GDSWRU HQJWK ROODU 3ODWH 6HWWLQJ 9HQW SRVLWLRQ 1 Loosen 2 x Phillips screws on both right and left legs 2 See above diagram below for required leg setting 3 Install with supplied Phillips screws to pre punched holes and tighten previous screws that were loosened in Ste...

Page 38: ... outlined in your unit specific installation guide 4 Using the a ring clamp and or 3 self drilling sheet metal screws attach the Vent Slide Plate to the Flex Vent Section STEP 1 VENT CONNECTION TYPE B 1 Remove the 6x 8 sheet metalscrews from the top of the Vent Slide Plate 2 Locate the Adaptor Plate on the top of the Slide Plate Retainer and attach with 4 x 8 screws removed in the previous step 3 ...

Page 39: ...e and centered fasten the outer shell to the existing firebox using self tapping screws 1 Ensure thermodiscs and thermodisc brackets are in place 2 Install the firebox into the outer shell by sliding the drafthood bottom onto the drafthood slide until you are able to install 4 screws to secure the firebox Use care to avoid damaging the wire harness Note 2 of the screws along with panel brackets to...

Page 40: ...tlet is on the right side of the unit feed power cord through right grom met and use wire clips to secure power cord inside the unit 8 Secure backing plate with mounting brackets to outer box by screwing 4 self tapping screws on flanges 10 Reinstall glass door see instructions in manual 11 Install control cover adjust horizontal alignment by sliding control cover to ensure even spacing on both side...

Page 41: ...ram 2 Receiver in position 3 Install remote receiver from any of the approved remote controls on the far right hand side of the unit See Diagram 2 Basic Remote receiver shown 4 Disconnect red wire from TH terminal on valve see Diagram 3 5 Cut the female wire spade from the disconnected red wire at the end of connector see Diagram 4 Bare the same red wire using wire strippers in order to connect ne...

Page 42: ... for coding instruc tions and battery installation Important Note When remote control is coded ensure that the ON OFF switch is in the on position or facing up and the remote receiver is in the remote position Diagram 7 Diagram 8 Diagram 9 WHITE WHITE GREEN BLACK ROTARY SPEED CONTROL THERMODISC RED BLACK BLACK BLACK HI LIMIT SWITCH SPILL SWITCH 2 WAY SWITCH REMOTE CONTROL WALL THERMOSTAT TO TH TP ...

Page 43: ...led with the red o ring visible Fig 5 14 Re assemble the black protection cap Fig 6 Burner Orifice Fig 1 Fig 2 Fig 3 Fig 4 LPG Configuration Red o ring visible Fig 5 Fig 6 LP conversion Kit 616 969 1 904 037 LP orifice injector 35 1 904 977 orifice 55 1 908 528 Propane Label Red 1 918 590 Converted to LPG label 1 904 529 Allen Key 1 919 191 Instruction Sheet 17 Attach the label This unit has been ...

Page 44: ...slide the mixing tube over the orifice 2 Make sure to feed the Air Shutter Bar through the lower hole in the valve tray just above the ignitor as you place the Glass Burner in 3 Screw down the Glass Burner with two screws 4 Hang the Front Burner Cover on the front edge Diagram 11 1 Diagram 11 2 Diagram 11 3 Diagram 11 4 ...

Page 45: ...es prior to installation All claims to be recorded at this time Claims for damage after installation will not receive consideration Black Enamel panels will discolor a little during normal operation This is normal and should not be considered a defect All hand and finger marks MUST be cleaned off with a soft cloth Use an ammonia based cleaner ie glass cleaner to remove any fin gerprints before app...

Page 46: ...using Ceramic Spa Stones DO NOT cover burner ports or pilot light that lead to pilot flame Ensure the crystals or stones do not overlap excessively as this will effect the flame pattern OPTIONAL SPA OR VOLCANICSTONES INSTALLATION AROUND BURNER NOTE Spa or Volcanic Stones are NOT to be placed anywhere on the burner tube or Pilot assembly area NOTE Correct final glass installation of Crystals shown ...

Page 47: ...e back wall of the firebox 2 Slide in side panel 3 Positon panel so that grout line in the panel lines up with screw in the baffle 4 If required lower screw to secure panel in position 5 Repeat steps 2 4 on other side Line up screw and grout line Final Install BRICK PANEL INSTALLATION ...

Page 48: ...nstructions below carefully and refer to the images If the are broken do not use the unit until they are replaced Broken logs interfere with pilot operation Improper positioning of the logs may create carbon build up and alter the unit s performance which is not covered under warranty Log Kit 619 935 contains the following pieces 1 Place Log A over the two posts at the back of the log burne Instal...

Page 49: ...ce ember lava platinum embers and embaglow on the burner being careful not to cover the pilot or the gas ports 5 Place Log D on the left pin of Log A and the groove in Log B A B C D 6 Place Log E on the right pin on Log A and on top of Log C A A B D C E E Ember Lava Embaglow Platinum Embers Final Install ...

Page 50: ...l 3 Carefully remove the logs from the packaging and unwrap them The logs are fragile handle with care never force into position 4 Ensure glass crystals are installed on the burner E18 5lbs 5 Install log brackets by clipping brackets to back of burner tray measure 4 from outside edge of the burner tray to outside edge of bracket Brackets installed 4 from outside edge of burner tray 6 Install Rear ...

Page 51: ...al install Installed position of Log 3 1 3 2 4 11 InstalledLog3shouldtouchburnerpositioninthelocationshownbelow Measurement taken from left edge of burner tray approximately 18 1 5 2 1 2 3 4 18 2 1 4 10 13 Place lava embers rocks on glass ensure rocks do not block pilot Do not place lava rocks embers too close to logs as this may cause carboning 14 Adjust aeration see unit manual for setting 15 Re...

Page 52: ...er to reattach 4 Install control cover supplied with screen RRU UDPH 7DE RRU UDPH GLASS DOOR INSTALLATION 1 Hang Glass Door over the Door Frame Tabs 2 Two Screws tighten the door on the two lower Glass Door Tabs RQWURO RYHU RRU 5HWDLQHUV 6FUHZV Diagram 13 1 Diagram 13 2 Diagram 13 3 WARNING Do not operate appliance with the glass front removed cracked or broken Replacement of the glass should be d...

Page 53: ...e used DRAFTHOOD CHECK A spillage test must be made before the in stalled unit is left with the customer Follow the procedure below 1 Start all exhaust fans in the home and then close all external doors and windows in the house Remove the Front Trim from the E18 to gain better access to the Drafthood Opening Make sure the Glass Door is on properly 2 Light the unit and set controls to maximum 3 Aft...

Page 54: ...ON CONTROLS FIREPLACE CONTROLS The E18 has 3 controls for controlling flame height fan speed and flame on off The fan on the E18 is designed to come on once the fireplace has reached a pre deter mined temperature and to go off once the temperature has dropper following use The speed of the fan can be varied by adjusting the Fan Speed Control dial up or down These controls are located to the left s...

Page 55: ...ontinually push and release the black button on spark igniter until pilot lights Continue to hold the control knob in for approximately one minute then release the gas control knob The pilot flame should continue to burn If the pilot does not remain lit repeat operation allowing a longer period before releasing gas control knob 6 Verify log placement If the pilot cannot be seen when lighting the u...

Page 56: ...FORE LIGHTING This appliance must be installed in accordance with local codes if any if none follow the National Fuel Gas Code ANSI Z223 1 NFPA 54 or Natural Gas and Propane Installations Codes CSA B149 1 Australia AG601 New Zealand NZS 5261 WARNING If you do not follow these instructions exactly a fire or explosion may result causing property damage personal injury or loss of life Improper instal...

Page 57: ...kage of the glass Do not strike or abuse the glass Do not operate this fireplace without the glass front or with a cracked or broken glass front Wear gloves when removing damaged or broken glass Replacement of the glass panels should be done by a licensed or qualified service per son GLASS REPLACEMENT In the event that you break your glass by impact purchase your replacement from an authorized Reg...

Page 58: ...nstructions in this manual 6 Unplug the TH and TN TP wires on the front of the Valve VALVE REPLACEMENT INSTALLING VALVE 7 Disconnect piezo wire from piezo ignitor 8 Unscrew the 8 screws holding down the Valve Tray 9 Slide the Valve Tray out about half way giving easier access to the gas connection at the valve 1 Place new valve tray and gasket into position 2 Reverse Steps 10 1 3 Check for gas lea...

Page 59: ...anual 4 Remove Log Set and Embers or crystals and stones if installed 5 Remove Burner and Panels see instructions in manual 6 Remove Valve Tray see previous page 7 Disconnect Ground Wires and unclip Safety Circuit Wires and remove through Grommet 8 Loosen 4 screws holding in Air Inlet Baffle and remove it 9 Loosen 3 screws holding in the Circulation Fan 10 Disconnect Power Leads on Fan Motor 11 Re...

Page 60: ...n but a thermal safety switch will cut out the appliance before it gets to hot The unitl will cycle on and off as required to stay within temperature specifications Caution Ensure that the wires do not touch any hot surfaces and are away from sharp edges When connected with 120 volts the appliance must be electrically grounded in accordance with local codes or in the absence of local codes the cur...

Page 61: ...er 4 616 043 Fan Mounting Bracket 16 616 071 Control Box 5 616 515 Log Tray 17 910 246 On Off Switch 6 616 930 Log Set 18 616 901 2 Brick Panels White cord channel 19 904 943 Orifice Mount 8 616 929 Mesh screen 20 910 190 Piezo Ignitor 9 616 040 Glass door 21 904 946 Gas Orifice 10 616 048 Surround Bracket L 22 910 034 Pilot Assembly 11 911 119 Spill Switch 23 616 526 Burner 12 W241050 Fan Switch ...

Page 62: ...16 070 Adaptor plate gasket 7 E18 Body 2 616 069 Adaptor plate 8 616 068 Surround Panel Rear 3 9 616 067 Surround Panel Right 4 904 960 Ring clamp Installer supplied 10 Magnet and Bracket 5 948 338 Flex Vent Section Installer supplied 11 616 051 Control Cover 6 616 023 Flue Slider Plate 12 Diagram 21 1 ...

Page 63: ...1 616 070 Adaptor plate gasket 7 E18 Body 2 616 069 Adaptor plate 8 616 068 Surround Panel Rear 3 9 616 067 Surround Panel Right 4 904 960 Ring clamp Installer supplied 10 Magnet and Bracket 5 948 338 Flex Vent Section Installer supplied 11 616 051 Control Cover 6 616 023 Flue Slider Plate 12 Diagram 22 1 ...

Page 64: ...64 Regency E18 Gas Fireplace Insert PARTS LIST 0RQWLJR 65 QVWDOODWLRQ LW Diagram 23 1 ...

Page 65: ...Regency E18 Gas Fireplace Insert 65 PARTS LIST LUHVRQJ 1 QVWDOODWLRQ LW Diagram 24 1 ...

Page 66: ...allation Kit Item Part Description Item Part Description 8 Faceplate panel Front 3 Ring Clamp 9 Magnet Bracket not shown 4 Flex section 10 Control Cover 5 Adaptor Slide Plate 11 Firesong 120N Firebox supports 6 E18 Chassis 7 Faceplate panel Rear 6 4 5 3 7 8 10 11 11 ...

Page 67: ...ted distributor or agent provided that the defective part be returned to the distributor or agent Transportation Prepaid if requested Porcelain Enamel Absolute perfectionisneither guaranteednor commercially possible Any chips must be reported and inspected by an authorized dealer within three days of installation Reported damage after this time will be subject to rejection It is the general practi...

Page 68: ...__________________________________________________________ Phone ___________________________________________________________ Date Installed ______________________________________________________ Serial No __________________________________________________________ Register your Regency warranty online www regency fire com Reasons to register your product online today View and modify a list of all y...