background image

26

 | 

Regency CS1200  Freestanding Wood Stove

 | 

26

operating instructions

ASH DISPOSAL

During constant use, ashes should be removed 

every few days. The  Ash Drawer option features 

a convenient ash dump for easy removal of ash, 

refer to the "Modular Options" section.

Safety Precautions

1)

  Do not allow ashes to build up to the loading 

doors!  Only remove ashes when the fire has 

died down.  Even then, expect to find a few hot 

embers.

2)

  Please take care to prevent the build-up of ash 

around the start-up air housing located inside 

the stove box, under the loading door lip.

3) 

Never start a fire if the ash plug and ash drawer 

are not in place. This will cause overfiring which 

can cause excessive warping of the stove. 

Evidence of overfiring can void the warranty 

on your stove.

4)

  The firebricks are brittle and can be damaged 

if the plug is replaced carelessly or pieces that 

are too large are forced through the hole. 

Ash Drawer Operating Guideline 

1)

  Only clean ashes out of the stove when the 

stove is cold.  Remove the plug by lifting on the 

handle using the tool provided. Push the ashes 

down the hole into the ash drawer, the large 

pieces can be left in the firebox and burned 

during  the  next  fire  or  removed  through  the 

door opening.

2)

  Always leave 1/2 to 1 inch of ash in the bottom 

of the firebox.  This helps in easier starting and 

a more uniform burn of your fire. Replace ash 

plug when ashes have been removed.

3)

  Open the lower surround door by hooking two 

fingers in the slot near the left side - pull open 

towards the right.

4)

  When emptying the ash drawer, make sure 

the ashes are cold. Ashes should be placed 

in a metal container with a tight fitting lid.  The 

closed container of ashes should be placed on 

a non - combustible floor or on the ground, well 

away from all combustible materials, pending 

final disposal.  If the ashes are disposed of by 

burial in soil or otherwise locally dispersed, they 

should be retained in the closed container until 

all cinders have thoroughly cooled.  Other waste 

should not be placed in the ash container.

5)

  Before putting the ash drawer back into place, 

make sure the ash plug is back in place. 

 

Summary of Contents for CS1200 Alterra

Page 1: ...9 CS1200 Alterra Freestanding Wood Stove 09 15 15 Owner s Installation Manual Tested by Installer Please complete the details on the back cover and leave this manual with the homeowner Homeowner Please keep these instructions for future reference French Manual Download http bit ly 1E1h5ew ...

Page 2: ...here the majority of the chimney is within the building envelope and fully lined It is against federal regulation to operate this wood heater in a manner inconsistent with operating instructions in this manual or if any parts are removed It is against federal regulation to operate this wood heater in a manner inconsistent with operating instructions in this manual CAUTION BURN UNTREATED WOOD ONLY ...

Page 3: ...Stainless steel smoke deflector adjustment replacement 15 Baffle and tube Installation 16 Brick Installation 16 Door Handle 16 Side panel Installation 17 Ash drawer option 18 Lower Surround door reversal 19 left to right side opening 19 Cast Door reversal 19 Wood Storage 21 Optional Ashlip installation 21 Optional outdoor Air kit installation 22 Blower Fan installation 23 Fan Operation 23 Fan wiri...

Page 4: ...LAPORTEFERMÉE OUVRIRLAPORTEDECHARGEMENT POUR ALIMENTER LE FEU SEULEMENT NE PAS UTILISER DE GRILLE À BÛCHES NI SURÉLEVER LE FEU MONTER LE FEU DE BOIS DIRECTEMENT SUR L ÂTRE NE PAS SURCHAUFFER SI LE POÊLE OU LE CONNECTEUR DE CHEMINÉE SE MET À ROUGIR VOUS SURCHAUFFEZ INSPECTEZ ET NETTOYEZ FRÉQUEMMENT LA CHEMINÉE ET LE CONNECTEUR EN CERTAINES CONDITIONS D UTILISATION UN DÉPÔT DE CRÉOSOTE PEUT SE FORME...

Page 5: ...DIMENSIONS 9 15 16 14 7 16 39 9 16 1105mm 17 1 8 436mm 26 3 4 680mm A A 21 3 4 552mm 37 13 16 961mm 19 1 16 485mm 250mm 367mm 17 1 8 436mm 27 1 8 689mm 9 15 16 250mm 7 5 16 186mm 17 1 8 435mm CL for outside air 6 flue collar Shown with optional blower installed ...

Page 6: ...f the door opening and 6 to the sides and rear of the unit Someareasmayrequirealargersizefloorprotector See your local inspector For outside air installation refer to Mobile Home section 8 When the floor protection is complete position the stovewiththefluecollarcenteredundertheinstalled chimney 9 In seismically active areas Regency recommends that your unit is secured to the floor by using the bol...

Page 7: ...er line CS1200 A B C D E F 13 11 8 26 3 8 18 1 2 20 3 4 Residential Close Clearance To be installed with required pipe components When the stove is installed as a close clearance residential unit a listed double wall connector is required from the stove collar to the ceiling level From Unit From Corner From Flue Center line CS1200 A B C D E F 11 7 7 24 1 2 14 5 19 3 4 Mobile Home Close Clearance T...

Page 8: ...m 16 from the fuel door opening of the stove and minimum 6 or the rear clearance to combustibles whichever is smaller from the rear of the stove NOTE In Canada floor protection must extend 18 to the front and 8 to each side of the stove Minimum Alcove Clearance to Combustible Materials Unit From Back Shield Side Shields From Flue Center Line Min Width Min Hearth to Rear Wall CS1200 G H I J K L 11 ...

Page 9: ... It is recommended that no ceiling support member be cut for chimney and support box installation If it is necessary to cut them the members must be made structurally sound 2 Install radiant shield and support from above 3 Stacktheinsulatedpipeontoyourfinishsupport to a minimum height of 3 feet above the roof penetration or 2 feet above any point within 10 feet measured horizontally There must be ...

Page 10: ...se mortar or other signs of deterioration and blockage Have the chimney cleaned beforethestoveisinstalledandoperated Whenconnect ing the stove through a combustible wall to a masonry chimney special methods are needed Ensure that an effective vapour barrier at the location where the chimney or other component penetrates to the exterior of the structure MASONRY FIREPLACE There are listed kits avail...

Page 11: ...y clearance to brick and combustibles 2 in 50 8mm Minimum clearance 12 in 304 8mm of brick Chimney connector Fire clay liner Method C 6 152 4 mm Clearance to Combustible Wall Member Starting with a minimum 24 gage 024 61 mm 6 152 4 mm metal chimney connector and a minimum 24 gage ventilated wall thimble which has two air channels of 1 25 4 mm each construct a wall pass through There shall be a min...

Page 12: ...deg elbow 2 ft T 3 ft Each foot of horizontal run 2 ft 3 Add 4 overall for each 1000 above sea level Example a 1 1 2 ft of horizontal run 3 ft one T 3 ft Total Addition at sea level 6 ft Example b One 90 deg elbow 2 ft 2 ft of horizontal run 4 ft one T 3 ft Total Addition at sea level 9 ft Recommended Flue Height Elevation Example a Example b 0 18 21 1000 18 72 21 84 2000 19 44 22 68 5000 21 60 25...

Page 13: ...ugh 8 a supply of fresh air has to be supplied to your unit Cut a minimum 4 inch diameter hole through your outside wall Use 4 duct pipe with a mesh grill to pipe fresh air into the back shield area Place your unit in position and secure it to the floor using two lag bolts 3 8 x 3 1 2 through the two holes inside the pedestal base It is important to maintain the structural integrity of the Mobile ...

Page 14: ...OBILE HOME INSTALLATION The Regency CS1200 is approved for installation in a Mobile Home if one of the following pipe systems is used U S Installation METALBESTOS SSII Qty Part Description 1 6DS VK Connector Kit 1 6TMH Shield Support 1 6TAF 6 Flashing 1 6T 36 Chimney Length 1 6T 18 Chimney Length 1 6T CT Rain Cap PRO JET 3103 Qty Part Description 1 PV06 TK Connector 1 CSB Shield Support 1 RRS Radi...

Page 15: ... loosen off both bolts and slide defector upward and out Install new defector and hand tighten bolts Ensure positive location of the defector prior to hand tightening WARNING Operation of the unit with out proper installation of smoke deflector will void warranty Smoke deflector is installed through the door opening in location shown in diagram Smoke deflector Ensure defector is seated so bolts ar...

Page 16: ...e and then slide it back over the rear air tube 3 Tilt the left baffle brick up on top of the side channel and it will leave enough room to position the right baffle brick in the same manner as Step 1 above Then reposition the left baffle brick flat on the air tube The door handle can be removed and stored on a hanger located on the inside left in the wood storage area 4 Important push both baffle...

Page 17: ...efore applying heat to the unit Failure to do this will result in burn stains on panels which you will be unable to remove Not protected by product warranty One set of side panels needs to be installed on the stove When installing stainless steel side panels follow the handling and cleaning instructions below 1 Bend the metal tab located in the top front corner of the side panels to a 45 angle wit...

Page 18: ...operating instructions 1 Open the main top door and the center door on the front of the unit 3 Remove the ash dump cover plates one inside the firebox and one on the underside of the firebox access the lower plate through the center door it is directly below the upper ash dump plate by removing the two nuts and bolts holding the 2 plates together from underneath the stove Ash Dump Plates Ash Plug ...

Page 19: ...olts 2 Remove the latch on the left side of the unit by removing 2 bolts 3 Rotate the latch 180 and reinstall on the right side 4 Rotate both hinge 180 and reinstall hinge on left side 5 Remove and rotate both the male part of the latch 180 located on the inside of the lower surround door Install the latch on the opposite side of the door Door latch male portion 6 Reinstall the door do not rotate ...

Page 20: ...the 2 bolts securing the door catch assembly to the unit 6 Remove the glass from the door and flip it around 180 so the painted strip is at the bottom of the door 7 Flip the handle around 180 and reattach to the door with 2 bolts Center of pin will need to be tapped to offset opposite side of cam 4 Flip the door hinge 180 install on the left side of the unit with 2 bolts 5 Reattach the door catch ...

Page 21: ...aper within pedestal Note Please refer to local codes B365 NFPA211 and your local jurisdiction Store wood behind door opening 1 Open lower surround door 2 Ashlip to be positioned just below the ashdrawer if installed 3 Manoeuvre ashlip into position on an angle the tabs on the ashlip rest behind side walls on unit see diagrams below Tabs on ashlip Final install of Ashlip Ashlip to be positioned he...

Page 22: ...n below to remove backing plate 2 Center the plate pipe over the opening on the back of the stove Secure with 4 self tapping screws 3 Reinstall the backing plate over the air kit pipe Secure with 4 bolts removed from step 1 Move unit into place 4 On the outside of the building slide cap over end to pipe to complete the installation ...

Page 23: ...nce is equipped with a three pronged grounding plug for your protection against shock hazard and should be plugged directly into a properly groundedthree prongreceptacle Donotcutorremove the grounding prong from this plug NOTE This appliance when installed must be electrically grounded in accord ance with local codes or in the absence of local codes with the National Electrical Code ANSI NFPA 70 o...

Page 24: ... sides Softer woods like pine spruce and poplar aspen that is cut split and stacked properly in the early spring maybe be ready for burning in the fall Extremely hard woods like oak and maple and large pieces of firewood may take a minimum of a full year to dry enough Drying may also take longer in damp climates There are a few ways to tell if wood is dry enough to burn efficiently Use as many ind...

Page 25: ...the fireplace stove opening creat ing risks from both fire and smoke DRAFT CONTROL Both the primary and air wash drafts are controlled by the control rod located on the left side of the unit when facing the unit To increase your draft pull open and to decrease push closed All units have a secondary draft system that continually allows combustion air to the induction ports at the top of the firebox...

Page 26: ...t of the stove when the stove is cold Remove the plug by lifting on the handle using the tool provided Push the ashes down the hole into the ash drawer the large pieces can be left in the firebox and burned during the next fire or removed through the door opening 2 Always leave 1 2 to 1 inch of ash in the bottom of the firebox This helps in easier starting and a more uniform burn of your fire Repl...

Page 27: ...ct this unit to a chimney flue serv ing another appliance 10 Do not use grates or andirons or other methods for supporting fuel Burn directly on the bricks 11 Open the draft control fully for 10 to 15 seconds prior to slowly opening the door when refuelling the fire 12 Do not connect your unit to any air distribution duct 13 Your woodstove must burn dry seasoned standard firewood only The use of c...

Page 28: ...hen removing broken glass to avoid injury When placing the replacement glass in the door make sure that the glassgasketingwillproperlysealyourunit Replace the retainer it should rest on the gasket not the glass and tighten securely with a glass clips and screws Do not wrench down on the glass as this may cause breakage Do not use substitute materials If your glass does break do not continue to use...

Page 29: ... the seal on the loading door with a paper bill Place a paper bill in the gasketed area of the door of a cold stove Close the door Try to remove the paper by pulling The paper should not pull out easily if it does try adjusting the door latch if that doesn t solve the problem replace the door gasket Check and lubricate door hinge latch Use only high temperature anti seize lube ie never seize Check...

Page 30: ...t 076 927 Side Shield Stainless Set 7 156 519 Door Catch Assembly 8 076 516 Heat Shield 9 156 523 Door Hinge Assembly 10 942 110 Ash drawer plug 11 076 911 Ash Drawer Assembly 12 076 004 Fan Opening Cover 13 076 010 Back Shield 14 074 954 Air tube 15 033 953 Air tube 16 073 955 Baffle set 17 076 913 Ashlip 18 820 483 Smoke Deflector Part Description Firebox Assembly 940 366 P Neoceram Glass 919 53...

Page 31: ...ottom 3 222 036 Sensor Mount 4 200 227 Fan Bracket Right Hand 5 200 228 Fan Bracket Left Hand 6 200 229 Fan Housing Back 7 910 157 P Fan 8 910 142 Thermodisc Part Description 1 076 960 Firebrick Set RED LOW WHITE COMMON CONNECTION DIAGRAM BLACK HIGH 115V 60HZ 1 1A J250 150 O44003 T P 3000 RPM JAKEL INC DATE T P L B 5 6 2 3 4 7 8 1 FAN ASSEMBLY FIRE BRICK ...

Page 32: ...32 Regency CS1200 Freestanding Wood Stove 32 notes ...

Page 33: ...RRegency CS1200 Freestanding Wood Stove 33 33 notes ...

Page 34: ...34 Regency CS1200 Freestanding Wood Stove 34 notes ...

Page 35: ...on the warranty will be invalid Exclusions This limited Lifetime Warranty does not extend to or include paint door or glass gasketing firebrick back sides bottom or trim It does not cover installation and operational related problems such as over firing use of corrosive driftwood wood preservatives metal foils coal plastic garbage sulphur mill ends oils solvents petroleum products railroad ties pape...

Page 36: ...___________________________________________ Serial No ___________________________________________________________ Register your Regency warranty online www regency fire com Reasons to register your product online today View and modify a list of all your registered products Request automatic email notification of new product updates Stay informed about the current promotions events and special offe...

Reviews: