safety decal

This is a copy of the label that accompanies 

each Regency Small Freestanding Woodstove 

(F1100S).

We have printed a copy of the contents here 

for your review.

NOTE:

 Regency units are constantly being 

improved. Check the label on the unit and if 

there is a difference, the label on the unit is the 

correct one.

COPY OF SAFETY LABEL FOR F1100S

duplicate serial number

Part #: 908-281c

Size:   6.53" H x 10.8" W (File at 100%)

Color: black on grey except for the items indicated as being printed in red.

Jan. 2/08: updated yrs. of manufacture.

Mar. 15/10: updated yrs. of manufacture.
Jan 10/13: updated yrs. of manufacture.

Feb. 24/14: Rev. B - added French

Mar. 11/14: Updated Floor Clearances

Nov. 25/14: Rev C - updated ETL logo

MINIMUM ALCOVE CEILING HEIGHT: 2.15 M / 7 FT         MAXIMUM ALCOVE DEPTH 915 MM / 36 IN.    

MINIMUM CLEARANCES FOR HORIZONTAL CONNECTOR TO CEILING: 455 MM / 18"

THE SPACE BENEATH THE HEATER MUST NOT BE OBSTRUCTED. OPERATE ONLY WITH FIREBRICKS IN PLACE.

F1100S WITHOUT 

AIRMATE SHIELD

F1100S WITH 

AIRMATE SHIELD

FOR USE WITH SOLID WOOD FUEL ONLY.  USE OF OTHER FUELS MAY DAMAGE HEATER AND CREATE A HAZARDOUS CONDITION.  DO NOT OBSTRUCT COMBUSTION 

AIR OPENINGS.  OPERATE ONLY WITH FIREBRICKS IN PLACE.  RISK OF SMOKE AND FLAME SPILLAGE, OPERATE ONLY WITH DOORS FULLY OPEN OR FULLY CLOSED. 

IF INSTALLED IN A MOBILE HOME OPERATE ONLY WITH DOORS FULLY CLOSED - OPEN FEED DOOR TO FEED FIRE ONLY. WHEN OPERATED WITH DOORS OPEN THE 

MANUFACTURER SUPPLIED SCREEN MUST BE USED. DO NOT USE GRATE OR ELEVATE FIRE.  BUILD WOOD FIRE DIRECTLY ON HEARTH.  DO NOT OVERFIRE - IF HEATER 

OR CHIMNEY CONNECTOR GLOWS YOU ARE OVERFIRING.  INSPECT AND CLEAN CHIMNEY AND CONNECTOR FREQUENTLY.  UNDER CERTAIN CONDITIONS OF USE 

CREOSOTE BUILDUP MAY OCCUR RAPIDLY.  KEEP FURNISHINGS AND OTHER COMBUSTIBLE MATERIAL AWAY FROM HEATER.  REPLACE GLASS ONLY WITH NEOCERAM 

GLASS. COMBUSTIBLE FLOOR MUST BE PROTECTED BY NON-COMBUSTIBLE MATERIAL EXTENDING BENEATH THE HEATER AND TO THE FRONT AND SIDES AS INDICATED 

OR TO THE NEAREST PERMITTED COMBUSTIBLE MATERIAL.

OPTIONAL COMPONENT: FAN, ELECTRICAL RATING: VOLTS 115, 60 HZ, 2 AMPS, SCREEN DOOR

DANGER: RISK OF ELECTRIC SHOCK. DISCONNECT POWER BEFORE SERVICING UNIT. DO NOT ROUTE POWER CORD UNDER OR IN FRONT OF APPLIANCE.

COMPONENTS REQUIRED FOR MOBILE HOME INSTALLATION: OUTSIDE AIR KIT AND ONE OF THE FOLLOWING DOUBLE WALL CONNECTOR

IN CANADA:  LISTED SECURITY MODEL DP, OR OLIVER MACLEOD PRO-VENT PV DOUBLE WALLED CONNECTOR WITH  LISTED CHIMNEY SYSTEM: SECURITY MODEL 

S2100, ICC EXCEL 2100.

IN USA:   LISTED DOUBLE WALL CONNECTORS SECURITY MODEL DP, SELKIRK MODEL DS, OLIVER MACLEOD PRO VENT PV, SIMPSON DURA 

VENT MODEL DVL, GSW SUPER PIPE 6, METAL-FAB DOUBLE WALL.  CONNECTED TO ONE OF THE FOLLOWING COMPATIBLE CHIMNEY SYSTEMS 

SECURITY MODEL S2100 OR MODEL ASHT, SELKIRK MODEL SSII, OLIVER MACLEOD PRO JET 3103, SIMPSON DURA PLUS, GSW MODEL SC OR 

METAL-FAB TEMP/GUARD, AMERI-TEC HS,  ICC EXCEL 2100 .  USE CHIMNEY COMPONENTS AS SPECIFIED IN INSTALLATION INSTRUCTIONS.

AUTEUR MINIMALE DU PLAFOND DE L’ALCÔVE : 2.15 M / 7 PL   PROFONDEUR MAXIMALE DE L’ALCÔVE : 915 MM / 36 PO

DÉGAGEMENT MINIMAL DU PLAFOND POUR UN CONNECTEUR HORIZONTAL : 455 MM / 18 PO.

L’ESPACE AU-DESSOUS DU POÊLE NE DOIT PAS ÊTRE OBSTRUÉ. UTILISER SEULEMENT AVEC LES BRIQUES RÉFRACTAIRES EN PLACE.

POUR UTILISATION AVEC BOIS SOLIDE SEULEMENT. L’UTILISATION D’AUTRES COMBUSTIBLES PEUT ENDOMMAGER LE POÊLE ET CRÉER UNE CONDITION DANGEREUSE. 

NE PAS OBSTRUER LES OUVERTURES D’AIR DE COMBUSTION. UTILISER SEULEMENT AVEC LA PORTE FERMÉE – OUVRIR LA PORTE DE CHARGEMENT POUR ALIMENTER 

LE FEU SEULEMENT. NE PAS UTILISER DE GRILLE À BÛCHES NI SURÉLEVER LE FEU. MONTER LE FEU DE BOIS DIRECTEMENT SUR L’ÂTRE. NE PAS SURCHAUFFER – SI 

LE POÊLE OU LE CONNECTEUR DE CHEMINÉE SE MET À ROUGIR, VOUS SURCHAUFFEZ. INSPECTEZ ET NETTOYEZ FRÉQUEMMENT LA CHEMINÉE ET LE CONNECTEUREN 

CERTAINES CONDITIONS D’UTILISATION, UN DÉPÔT DE CRÉOSOTE PEUT SE FORMER RAPIDEMENT. GARDEZ LES MEUBLES ET AUTRES MATÉRIAUX COMBUSTIBLES 

ÉLOIGNÉS DU POÊLE. REMPLACEZ LA VITRE SEULEMENT PAR DU VERRE EN NEOCERAM. LE PLANCHER COMBUSTIBLE DOIT ÊTRE PROTÉGÉ PAR DES MATÉRIAUX NON 

COMBUSTIBLES DÉPASSANT DU DESSOUS, DU DEVANT ET DES CÔTÉS DU POÊLE, TEL QU’INDIQUÉ, OU JUSQU’AU MATÉRIAU COMBUSTIBLE LE PLUS PRÈS PERMIS.

COMPOSANTS EN OPTION : VENTILATEUR, ALIMENTATION ÉLECTRIQUE : 115 VOLTS, 60 HZ, 2 AMP.

DANGER : RISQUE D’ÉLECTROCUTION. DÉCONNECTER L’ALIMENTATION ÉLECTRIQUE AVANT DE FAIRE L’ENTRETIEN DU POÊLE. NE PAS INSTALLER LE CORDON 

ÉLECTRIQUE SOUS OU DEVANT L’APPAREIL.

COMPOSANTS EXIGÉS POUR INSTALLATION DANS UNE MAISON MOBILE : KIT DE PRISE D’AIR EXTÉRIEUR ET L’UN DES CONNECTEURS DE CHEMINÉE À DOUBLE PAROI 

SUIVANTS :

AU CANADA : CONNECTEURS DE CHEMINÉE HOMOLOGUÉS À DOUBLE PAROI : SECURITY MODÈLE DP, OU OLIVER MACLEOD PRO-VENT PV, AVEC SYSTÈME DE CHEMINÉE 

HOMOLOGUÉ : SECURITY MODÈLE S2100, ICC EXCEL 2100, SUPER VENT 2100.

AUX ÉTATS-UNIS : CONNECTEURS DE CHEMINÉE HOMOLOGUÉS À DOUBLE PAROI : SECURITY MODÈLE DP, SELKIRK MODEL DS, OLIVER MACLEOD PRO VENT PV, 

SIMPSON DURA VENT MODÈLE DVL, GSW SUPER PIPE 6, METAL-FAB À DOUBLE PAROI. CONNECTÉ À L’UN DES SYSTÈMES DE CHEMINÉE COMPATIBLES SUIVANTS : 

SECURITY MODÈLE S2100 OU MODÈLE ASHT, SELKIRK MODÈLE SSII, OLIVER MACLEOD PRO JET 3103, SIMPSON DURA PLUS, GSW MODÈLE SC OU METAL-FAB TEMP/

GUARD, AMERI-TECHS, ICC EXCEL 2100, SIMPSON DURA PLUS HTC. UTILISER LES COMPOSANTS DE CHEMINÉE SPÉCIFIÉS DANS LES INSTRUCTIONS D’INSTALLATION.

100

 CAUTION

HOT WHILE IN OPERATION DO NOT TOUCH.  KEEP CHILDREN,

CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSE

SKIN BURNS. READ NAMEPLATE AND INSTRUCTIONS.

ATTENTION

CHAUD DURANT LE FONCTIONNEMENT. NE TOUCHEZ PAS. 

ÉLOIGNEZ LES ENFANTS, LES VÊTEMENTS ET LES MEUBLES. 

LE CONTACT PEUT CAUSER DES BRÛLURES DE LA PEAU.

LISEZ LA PLAQUE SIGNALÉTIQUE ET LES INSTRUCTIONS

MADE IN CANADA / FAIT AU CANADA

MANUFACTURED BY/ FABRIQUÉ PAR:

FPI FIREPLACE PRODUCTS INTERNATIONAL LTD.

6988 VENTURE ST.

DELTA, BC  V4G 1H4

LISTED SPACE HEATER, SOLID FUEL TYPE,  ALSO 

SUITABLE FOR MOBILE HOME INSTALLATION / 

APPAREIL DE CHAUFFAGE AMBIANT HOMOLOGUÉ 

À COMBUSTIBLE SOLIDE, CONVENANT AUSSI

POUR INSTALLATION DANS UNE MAISON MOBILE 

FLOOR PROTECTION*

PROTECTION DE PLANCHER*

Au Canada, la protection de plancher doit dépasser de 

18 po (457 mm) à l’avant et de 8 po (200 mm) de chaque 
côté du poêle et derrière le 

poêle.

* In Canada, fl oor protection must extend 18" (450mm) 

to the front and 8" (200mm) to each side and back of 

the stove.

DO NOT REMOVE THIS LABEL/

 NE RETIREZ PAS CETTE ÉTIQUETTE

100

INSTALL AND USE ONLY IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION AND OPERATING INSTRUCTIONS.  

CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION IN YOUR AREA.  

USE 150 MM (6 IN.) DIAMETER MINIMUM 24 MSG BLACK OR 26 MSG BLUED STEEL CONNECTOR WITH LISTED UL103 HT 

FACTORY-BUILT CHIMNEY SUITABLE FOR USE WITH SOLID FUELS OR MASONRY CHIMNEY.  

SEE LOCAL BUILDING CODE AND MANUFACTURER'S INSTRUCTIONS FOR PRECAUTIONS REQUIRED FOR PASSING A 

CHIMNEY THROUGH A COMBUSTIBLE WALL OR CEILING.  DO NOT PASS CHIMNEY CONNECTOR THROUGH COMBUSTIBLE 

WALL OR CEILING.  DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.

INSTALLER ET UTILISER SEULEMENT SELON LES INSTRUCTIONS D’INSTALLATION ET D’UTILISATION DU FABRICANT. 

CONTACTER LES RESPONSABLES DU BÂTIMENT OU DU SERVICE-INCENDIE DE VOTRE RÉGION POUR CONNAÎTRE 

LES RESTRICTIONS ET EXIGENCES D’INSPECTION DANS VOTRE RÉGION. UTILISER UN CONNECTEUR D’UN DIAMÈTRE 

MINIMAL DE 150 MM (6 PO) 24 MSG EN ACIER NOIR OU 26 MSG EN ACIER BRONZÉ AVEC CHEMINÉE PRÉFABRIQUÉE 

HOMOLOGUÉE UL103 HT CONÇUE POUR UTILISATION AVEC COMBUSTIBLES SOLIDES OU UNE CHEMINÉE DE MAÇON-

NERIE.

VOIR LE CODE DU BÂTIMENT LOCAL ET LES INSTRUCTIONS DU FABRICANT CONCERNANT LES PRÉCAUTIONS  

EXIGÉES POUR INSTALLER UNE CHEMINÉE TRAVERSANT UN MUR OU PLAFOND EN MATÉRIAUX COMBUSTIBLES. 

NE FAITES PAS TRAVERSER LE CONNECTEUR DE CHEMINÉE DANS UN MUR OU PLAFOND EN MATÉRIAUX COMBUS-

TIBLES. NE RACCORDEZ PAS CE POÊLE À BOIS À UN CONDUIT DE CHEMINÉE DESSERVANT UN AUTRE APPAREIL.

908-281c

MODEL:  

REGENCY  SMALL  FREESTANDING STOVE -  F1100S

TESTED TO:  ULC S627-00 / UL 1482-2011 / UL 737    REPORT NO.6621

MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS 

DÉGAGEMENTS MINIMUMS AUX MATÉRIAUX COMBUSTIBLES

F1100S

 WITH AIRMATE SHIELD

F1100S

  WITHOUT AIRMATE SHIELD

RESIDENTIAL INSTALLATION USING

 SINGLE WALL  CONNECTOR

MEASURE     

 

 

       FLUE

FROM  

         HEATER   

         CENTER-LINE

RESIDENTIAL INSTALLATION USING

 SINGLE WALL  CONNECTOR

SIDEWALL  A 380  mm  /15  in  D 685  mm / 27  in

BACKWALL  B 265  mm / 10.5in  E  430  mm / 17  in

CORNER 

C 280  mm / 11  in  F  585  mm / 23  in

INSTALLATION USING LISTED DOUBLE WALL 

CONNECTOR -  MOBILE HOME 

SIDEWALL  A 330  mm / 13 in  D 635   mm / 25  in

BACKWALL  B 125  mm / 5  in  E  290  mm / 11.5in

CORNER 

C 230  mm / 9  in  F  535  mm / 21  in

INSTALLATION USING LISTED DOUBLE WALL 

CONNECTOR - RESIDENTIAL CLOSE CLEARANCE

SIDEWALL  A 345  mm / 13.5in  D 650 mm / 25.5 in

BACKWALL  B 125  mm / 5  in  E  290  mm / 11.5in

CORNER 

C 125  mm / 5  in  F  430  mm / 17  in

INSTALLATION USING LISTED DOUBLE WALL 

CONNECTOR - ALCOVE

SIDEWALL  A 330  mm / 13 in  D 635  mm / 25  in

BACKWALL  B 280  mm / 11 in  E  445  mm / 17.5 in

CORNER 

C 205  mm / 8  in  F  510  mm / 20  in

INSTALLATION USING LISTED DOUBLE WALL 

CONNECTOR -  MOBILE HOME 

SIDEWALL  A 280  mm / 11 in  D 585  mm / 23  in

BACKWALL  B 150  mm / 6  in  E  320  mm / 12.5 in

CORNER 

C 150  mm / 6  in  F  460  mm / 18  in 

SIDEWALL  A 230  mm / 9  in  D 535  mm / 21   in

BACKWALL  B 125  mm / 5  in  E  290  mm / 11.5in

CORNER 

C 75  mm / 3  in  F  380  mm / 15  in

INSTALLATION USING LISTED DOUBLE WALL 

CONNECTOR - RESIDENTIAL CLOSE CLEARANCE

SIDEWALL  G 280  mm / 11 in  I  585  mm / 23   in

BACKWALL  H 180  mm / 7  in  J  345  mm / 13.5 in

INSTALLATION USING LISTED DOUBLE WALL 

CONNECTOR - ALCOVE

SIDEWALL  G 330  mm / 13 in  I  635  mm / 25  in

BACKWALL  H 125  mm / 5  in  J  290  mm / 11.5in

MEASURE     

 

 

      FLUE

FROM  

       HEATER   

       CENTER-LINE

K  405 mm / 16 in

L  200 mm / 8 in

M  200 mm / 8 in

 JAN    FEB    MAR     

APR     MA

Y

   JUN     JUL

    

AUG    SEPT   OCT   NOV     DEC

DA

TE OF MANUF

ACTURE

2015

2017

2016

Summary of Contents for Classic F1100

Page 1: ...F1100S F3100L Classic F1100S F3100L Freestanding Woodstoves 09 14 15 Owners Installation Manual Tested by Installer Please complete the details on the back cover and leave this manual with the homeowner Homeowner Please keep these instructions for future reference www regency fire com F1100 Video ...

Page 2: ... test conditions this heater has been shown to deliver heat at rates ranging from 11 900 BTU hr to 42 900 BTU hr This unit has been tested using 5G series and generates the best efficiency when operated using well seasoned wood and installed in the main living areas where the majority of the chimney is within the building envelope and fully lined It is against federal regulation to operate this wo...

Page 3: ...Regency F1100 F3100 Freestanding Woodstove 3 3 F1100 Video Modular Parts ...

Page 4: ...ome Installation 16 Listed Components For Mobile Home Installation 17 Stainless steel smoke deflector adjustment replacement 18 Brick Flue Baffle Secondary Air Tube Installation 19 Screen Door 20 Contemporary Door Handle 20 Brick Installation 20 Classic Door Handle 20 Glass Installation 20 Optional Accessories 20 OPERATING INSTRUCTIONS Seasoned wood 22 Draft Control 23 Operating Instructions 23 Fi...

Page 5: ...S2100 ICC EXCEL 2100 SUPER VENT 2100 AUX ÉTATS UNIS CONNECTEURS DE CHEMINÉE HOMOLOGUÉS À DOUBLE PAROI SECURITY MODÈLE DP SELKIRK MODEL DS OLIVER MACLEOD PRO VENT PV SIMPSON DURA VENT MODÈLE DVL GSW SUPER PIPE 6 METAL FAB À DOUBLE PAROI CONNECTÉ À L UN DES SYSTÈMES DE CHEMINÉE COMPATIBLES SUIVANTS SECURITY MODÈLE S2100 OU MODÈLE ASHT SELKIRK MODÈLE SSII OLIVER MACLEOD PRO JET 3103 SIMPSON DURA PLUS...

Page 6: ...NÉEHOMOLOGUÉSÀDOUBLEPAROI SECURITYMODÈLEDP OUOLIVERMACLEODPRO VENTPV AVECSYSTÈMEDECHEMINÉE HOMOLOGUÉ SECURITY MODÈLE S2100 ICC EXCEL 2100 SUPER VENT 2100 AUX ÉTATS UNIS CONNECTEURS DE CHEMINÉE HOMOLOGUÉS À DOUBLE PAROI SECURITY MODÈLE DP SELKIRK MODEL DS OLIVER MACLEOD PRO VENT PV SIMPSON DURA VENT MODÈLE DVL GSW SUPER PIPE 6 METAL FAB À DOUBLE PAROI CONNECTÉ À L UN DES SYSTÈMES DE CHEMINÉE COMPAT...

Page 7: ...Regency F1100 F3100 Freestanding Woodstove 7 7 dimensions F1100S UNIT DIMENSIONS Contemporary Door Classic Door ...

Page 8: ...8 Regency F1100 F3100 Freestanding Woodstove 8 installation F3100L UNIT DIMENSIONS Contemporary Door Classic Door ...

Page 9: ...11 Do not connect this unit to a chimney serving another appliance unless approved by your local building authority 12 A chimney connector cannot pass through an attic or roof space closet or similar concealed space or a floor ceiling wall or partition of combustible construction In Canada if pas sage through a wall or partition of combustible construction is desired the installation shall conform...

Page 10: ...0 34 18 5 23 5 NOTE Be aware that local Codes and Regulations may override some clearances listed in this manual Check with your local inspector Residential Installation C Vent Single Wall Unit From Unit From Corner From Flue Center line A B C D E F Small F1100S with Airmate 13 11 8 25 17 5 20 with Rear Deflector 15 10 5 11 27 17 23 Large F3100L with Airmate 18 12 8 5 32 18 5 22 with Rear Deflecto...

Page 11: ... concrete board or certified to UL 1618 or as defined by local codes extend ing beneath the heater and a minimum of 8 from each side and minimum 16 from the front face of the stove and minimum 6 or the rear clearance to NOTE In Canada floor protection must extend 18 to the front and 8 to each side of the stove From From Flue Min Min Hearth Unit Unit Center line Width to Rear Wall G H I J K L Small...

Page 12: ...or F1100 F3100 Small 815 557 Large 815 558 Therearheatdeflectorissuppliedwiththestove andmustbeinstalledunlesstheoptionalairmate has been selected It stops the heat radiated from the flue collar from overheating the rear wall The rear heat deflector is installed on top of the rear heat shield as shown in Diagram 4 Pedestal Assembly Small 073 925 Large 063 925 1 For easier assembly tip the stove on...

Page 13: ...o initiallytrywiththeminimumrequired height and then if problems do arise add additional height at a later date 4 Slide the roof flashing over your chimney and seal the flashing to the roof with roofing compound Secure the flashing to your roof with nails or screws 5 Place the storm collar over the flashing sealing the joints with a silicone caulking 6 Fasten the raincap with spark screens if requ...

Page 14: ...gns of deterioration and blockage Have the chimney cleaned before the stove is installed and operated When connecting the stove through a combustible wall to a masonry chimney special methods are needed Ensure that an effective vapour barrier at the location where the chimney or other component penetrates to the exterior of the structure MASONRY FIREPLACE There are listed kits available to connect...

Page 15: ...himney clearance to brick and combustibles 2 in 50 8mm Minimum clearance 12 in 304 8mm of brick Chimney connector Fire clay liner Method C 6 152 4 mm Clearance to Combustible Wall Member Starting with a minimum 24 gage 024 61 mm 6 152 4 mm metal chimney connector and a minimum 24 gage ventilated wall thimble which has two air channels of 1 25 4 mm each construct a wall pass through Thereshallbeami...

Page 16: ... Residential Installation items 1 through 8 a supply of fresh air has to be supplied to your unit Cut a minimum 4 inch diameter hole through your floor protector and the floor directly under your pedestal base to the outside Use 4 duct pipe with a mesh grill to pipe fresh air into the pedestal area Block off the hole in the back of the pedestal with the square plate and the two 1 2 screws provided...

Page 17: ...ATION The Regency Small and Large Freestanding pedestal units are approved for installation in a Mobile Home if one of the following pipe systems is used U S Installation METALBESTOS SSII Qty Part Description 1 6DS VK Connector Kit 1 6TMH Shield Support 1 6TAF 6 Flashing 1 6T 36 Chimney Length 1 6T 18 Chimney Length 1 6T CT Rain Cap PRO JET 3103 Qty Part Description 1 PV06 TK Connector 1 CSB Shiel...

Page 18: ...red with 2 hand tightened bolts To replace the deflector loosen off both bolts and slide defector upward and out Install new defector and hand tighten bolts Ensure positive location of the defector prior to hand tightening WARNING Operation of the unit with out proper installation of smoke deflector will void warranty Smoke deflector is installed through the door opening in location shown in diagr...

Page 19: ...nd draft problems may occur if the bafflesareimproperlypositioned Checkthe position of the brick baffles on a regular basis as they can be dislodged if too much fuel is forced into the firebox The Large Stoves F3100L and S3100L are shipped with one of the secondary air tubes loose inside the firebox It needs to be installed after the brick baffle are installed Follow the directions below Small Sto...

Page 20: ...break OPTIONAL ACCESSORIES Freestanding Small F1100 BRICK INSTALLATION Firebrick is included to extend the life of your stoveandradiateheatmoreevenly Checktosee thatallfirebricksareintheircorrectpositionsand have not become misaligned during shipping The AD brick in the drawings above is the brick covering the Ash Dump hole that is used when the Ash Drawer Kit is installed refer to the Listed Comp...

Page 21: ... the Ash Drawer Operating section Bottom Shield Ash Drawer Kit 850 101 1 Remove the bricks from the floor of the firebox 2 Remove and discard the cover plate by removing the two screws on the front of the Bottom Shield 3 Remove the ash dump cover plates one inside the firebox and one on the underside of the firebox by removing the two nuts and bolts holding the 2 plates together from inside the fi...

Page 22: ...he sides Softer woods like pine spruce and poplar aspen that is cut split and stacked properly in the early spring maybe be ready for burning in the fall Extremely hard woods like oak and maple and large pieces of firewood may take a minimum of a full year to dry enough Drying may also take longer in damp climates There are a few ways to tell if wood is dry enough to burn efficiently Use as many i...

Page 23: ...ors fully closed If doors are left partly open gas and flame may be drawn out of the fireplace stove opening creating risks from both fire and smoke When operated with doors open the manufacturer supplied screen must be used DRAFT CONTROL Boththeprimaryandairwashdraftsarecontrol led by the control rod located on the left side of the unit when facing the unit To increase your draft pull open and to...

Page 24: ...AND WARNINGS 1 Never use gasoline gasoline type lantern fuels kerosene charcoal lighter fuel or similar liquids to start or freshen up a fire in your heater Keep all such liquids well away from the heater while it is in use 2 Keep the door closed during operation and maintain all seals in good condition 3 Donotburnanyquantitiesofpaper garbage and never burn flammable fluids such as gasoline naptha...

Page 25: ...ee your Regency Dealer GLASS MAINTENANCE Your Regency stove is supplied with 5 mm Neoce ram ceramic glass that will withstand the highest heat that your unit will produce In the event that you break your glass by impact purchase your replacement from an authorized Regency dealer only and follow our step by step instructions for replacement Allow the stove to cool down before cleaning the glass do ...

Page 26: ...olt 1 4 20 x 1 2 Hex Head 14 820 376 Retainer Plate Ash Dump Top 15 Nut 1 4 20 Hex 16 846 570 7 8 Door Gasket Repair Kit 17 948 079 bn Hinge Cap Nickel each 19 948 135 Spring Handle Large Nickel 20 948 136 Spring Handle Small Nickel 846 515 Complete Fan Blower Assy 120 V 25 910 684 Power Cord 120 V 27 910 142 Thermodisc Fan AutoON OFF 28 910 138 Manual Auto Switch 2 way 29 910 140 Fan Speed Switch...

Page 27: ...241 Cast Handle 20 948 144 Spring Handle Small Black 846 515 Complete Fan Blower Assy 120 V 25 910 684 Power Cord 120 V 27 910 142 Thermodisc Fan Auto ON OFF 28 910 138 Manual Auto Switch 2 way 29 910 140 Fan Speed Switch HI OFF LOW 3 way 30 910 157 P Fan Blower Motor 120 V 35 063 954 Air Tube 1 F3100 Qty 1 F1100 F3100 STOVE MAIN ASSEMBLY WITH CONTEMPORARY DOOR Part Description Part Description 07...

Page 28: ...Assy 58 942 110 Ash Plug 59 820 249 Ash Plug Tool Handle 56 850 121 Bottom Shield Small 850 321 Bottom Shield Large 57 Blanking Plate Btm Shield 850 101 Ashdrawer Kit Btm Shield 55 Ashdrawer Bottom Shield 58 942 110 Ash Plug 59 820 249 Ash Plug Tool Handle 140 850 126 Legs Cast Black 850 128 Legs Cast Brush Nickel 948 223 Regency Logo Nickel Not available as a replacement part PEDESTAL BOTTOM SHIE...

Page 29: ... 3 4 x 9 74 Brick Partial 1 1 4 x 4 1 2 x 3 1 2 76 Brick Partial 1 1 4 x 2 x 9 77 Brick Partial 1 1 4 x 3 1 4 x 9 78 Brick Partial 1 1 4 x 4 1 2 x 3 1 4 79 Brick Partial 1 1 4 x 4 1 2 x 2 1 4 80 Brick Partial 1 1 4 x 6 1 2 x 2 1 4 81 Brick Partial 1 1 4 x 1 1 4 x 9 82 Brick Partial 1 1 4 x 3 1 8 x 4 1 2 83 Brick Partial 1 1 4 x 3 3 8 x 9 84 Brick Partial 1 1 4 x 4 1 2 x 8 85 Brick Partial 1 1 4 x ...

Page 30: ...30 Regency F1100 F3100 Freestanding Woodstove 30 notes ...

Page 31: ...tion the warranty will be invalid Exclusions This limited Lifetime Warranty does not extend to or include paint door or glass gasketing firebrick back sides bottom or trim It does not cover installation and operational related problems such as over firing use of corrosive driftwood wood preservatives metal foils coal plastic garbage sulphur mill ends oils solvents petroleum products railroad ties pa...

Page 32: ...____________________________________________________ Phone ____________________________________________________________ Date Installed _______________________________________________________ Serial No ___________________________________________________________ Register your Regency warranty online www regency fire com Reasons to register your product online today View and modify a list of all your...

Reviews: