72
|
Bellavista® B36XTE-10 Gas Fireplace
|
72
maintenance
3. Check for evidences of excessive condensation,
such as water droplets forming in the inner
liner, and subsequently dripping out the joints,
Continuous condensation can cause corrosion
of caps, pipe, and fittings. It may be caused
by having excessive lateral runs, too many
elbows, and exterior portions of the system
being exposed to cold weather.
4. Inspect joints, to verify that no pipe sections or
fittings have been disturbed, and consequently
loosened. Also check mechanical supports such
as Wall Straps, or plumbers' tape for rigidity.
LOG REPLACEMENT
The unit should never be used with broken logs. Turn
off the gas valve and allow the unit to cool before
opening door and carefully remove the logs. (The
pilot light generates enough heat to burn someone.)
If for any reason a log should need replacement, you
must use the proper replacement log. The position
of these logs must be as shown in the Diagrams
under Log Installation.
Note: Improper positioning of logs may create
carbon build-up and will severely alter the
unit's performance which is not covered
under warranty.
GLASS GASKET
If the glass gasket requires replacement use a
tadpole glass gasket (Part # 936-155).
DOOR GLASS
Your Regency
®
fireplace is supplied with high
temperature 5mm-Ceramic glass. If your glass
requires cleaning, we recommend using an
approved glass cleaner available at all authorized
dealers. Do not use abrasive materials.
CAUTION & WARNINGS:
* Do not clean when the glass is hot.
* The use of substitute glass will void all
product warranties.
* Care must be taken to avoid breakage of
the glass.
* Do not strike or abuse the glass.
* Do not operate this fireplace without the
glass front or with a cracked or broken
glass front.
* Wear gloves when removing damaged or
broken glass.
* Replacement of the glass panels should be
done by a licensed or qualified service per
son.
GLASS REPLACEMENT
In the event that you break your glass by impact,
purchase your replacement from an authorized
Regency dealer only. Replacement glass (Part
#940-357/P) is shipped already installed into
the door frame. Reinstall as per Glass Door
Installation in the "Glass Door Removal" section.
MAINTENANCE INSTRUCTIONS
1. Always turn off the gas valve before cleaning.
For relighting, refer to lighting instructions. Keep
the burner and control compartment clean
by brushing and vacuuming at least once a
year. When cleaning the logs, use a soft clean
paint brush as the logs are fragile and easily
damaged.
2. Clean appliance and door with a damp cloth
(never when unit is hot). Never use an abrasive
cleaner. The glass should be cleaned with a gas
fireplace glass cleaner.
The glass should be
cleaned when it starts looking cloudy.
3. The heater is finished in a heat resistant
paint and should only be refinished with heat
resistant paint. Regency
®
uses StoveBright
Paint - Metallic Black #6309.
4. Make a periodic check of burner for proper
position and condition. Visually check the flame
of the burner periodically, making sure the
flames are steady; not lifting or floating. If there
is a problem, call a qualified service person.
5. The appliance and venting system must be
inspected before use, and at least annually,
by a qualified field service person, to ensure
that the flow of combustion and ventilation air
is not obstructed.
Note: Never operate the appliance without the
glass properly secured in place.
6. Do not use this appliance if any part has been
under water. Immediately call a qualified service
technician to inspect the appliance and to
replace any part of the control system and any
gas control which has been under water.
7. In the event this appliance has been serviced
check that the vent-air system has been properly
resealed & reinstalled in accordance with the
manufacturer's instructions.
8. Verify operation after servicing.
General Vent Maintenance
Conduct an inspection of the venting system
semi-annually. Recommended areas to inspect
as follows:
1. Check the Venting System for corrosion in areas
that are exposed to the elements. These will
appear as rust spots or streaks, and in extreme
cases, holes. These components should be
replaced immediately.
2. Remove the Cap, and shine a flashlight down
the Vent. Remove any bird nests, or other foreign
material.
1. Follow steps 1- 4 in Optional Light Install sec
-
tion in this manual.
2. Remove 2 screws to remove light diffuser
plus gasket.
3. Replace the bulb - do not touch bulb with
bare hands, use gloves or bulb packaging
to protect bulb.
4. Reverse steps.
BULB REPLACEMENT