40
Regency B36XTCE Gas Fireplace
INSTALLATION
CONVERSION KIT #576-972 FROM NG TO LP
for B36XTCE using SIT 886 NOVA Gas Valve
THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER
IF IN DOUBT DO NOT DO THIS CONVERSION !!
1)
Shut off the gas and electrical supply.
2)
Remove the louvers (and Arch screen
doors if they are installed).
3)
Open the fl ush door and remove the
door.
4)
Remove the logs and embers (if already
installed).
5)
Loosen the 2 screws holding the Burner
Assembly to the fi rebox base. Slide the
Burner Assembly to the left to release it
from the orifi ce and lift out.
Remove the 2 screws, push Burner Assembly
to the left and lift out.
9)
Unscrew the pilot orifi ce with the allen
key; then replace with the LPG pilot
orifi ce, provided in the kit.
7)
Remove the wire clip below the pilot cap.
10)
Re-install pilot cap and pilot shield.
11)
Remove burner orifi ce with a 1/2"
wrench. Use another wrench to hold on
to the elbow behind the orifi ce. Discard
orifi ce.
12)
Reinstall new burner orifi ce LPG
stamped #51 and tighten.
Each Kit contains one LP
Conversion Kit # 576-972
Conversion Kit Contains:
Qty. Part #
Description
1
904-645
Burner Orifi ce #51
1
904-529 5/32"
Allen
Key
1
918-590 Decal
"Converted
to
LPG"
1
908-528
Red "LP" label
1
910-037
LP Injector (Pilot
Orifi ce)
1
918-961 Instruction
Sheet
8)
Pull off the pilot cap to expose the pilot
orifi ce.
6)
Remove the pilot shield by removing 2
screws.
Installation of LP
Conversion Kit:
13)
Reinstall burner assembly.
14)
Adjust aeration accordingly.- see
manual for details.