background image

Regency Albany Freestanding Wood Fire

3

table of  

contents

Compliance Plate ..................................................................4

Unit Dimensions ....................................................................5

INSTALLATION

Residential Installation ...........................................................6

Safety Guidelines and Warnings ...........................................6

Cast Plate Installation ............................................................6

Clearance to Combustibles ....................................................7

Floor Protection .....................................................................7

 

OPERATING INSTRUCTIONS

Operating Instructions ...........................................................8
Air Slide Control.....................................................................8

First Fire

 ................................................................................8

3 speed fan operation ............................................................8

MAINTENANCE

Maintenance ..........................................................................9
Creosote ................................................................................9

 

- Ways to Prevent & Keep Units Free of Creosote

 .........9

Glass Maintenance ................................................................9
Door Latch Adjustment ..........................................................9
Wood Storage ........................................................................9
3 speed fan wiring diagram .................................................10

PARTS LIST

Heater Assembly .................................................................11
 

WARRANTY

Warranty ..............................................................................12

Summary of Contents for Albany

Page 1: ...tance or additional information consult an authorised installer service agency or the distributor FOR YOUR SAFETY Do not store or use petrol or other flammable vapours and liquids in the vicinity of this or any other appliance Installation and service must be performed by an authorised installer or service agency Model F200B 2 Albany F200B 2 Freestanding Wood Fire FPI FIREPLACE PRODUCTS AUSTRALIA ...

Page 2: ...wood fire is not properly installed a house fire may result For your safety follow the installation instructions contact local building fire officials or authority having jurisdiction about restrictions and installation inspection requirements in your area The authority having jurisdiction should be consulted before installation to determine the need to obtain a permit ONLY CLEAN APPLIANCE WITH A ...

Page 3: ...allation 6 Clearance to Combustibles 7 Floor Protection 7 OPERATING INSTRUCTIONS Operating Instructions 8 Air Slide Control 8 First Fire 8 3 speed fan operation 8 MAINTENANCE Maintenance 9 Creosote 9 Ways to Prevent Keep Units Free of Creosote 9 Glass Maintenance 9 Door Latch Adjustment 9 Wood Storage 9 3 speed fan wiring diagram 10 PARTS LIST Heater Assembly 11 WARRANTY Warranty 12 ...

Page 4: ...B 2 JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC 2017 2018 2019 2020 2021 TESTED BY HRL TECHNOLOGY PTY LTD TRAMWAY ROAD MORWELL VICTORIA 3840 May 2015 MAXIMUM AVERAGE HEAT OUTPUT BURNING HARDWOOD 11kW OVERALL AVERAGE EFFICIENCY BURNING HARDWOOD 70 Date of Manufacture Serial Number 918 796d 348 WHEN TESTED IN ACCORDANCE WITH AS NZS 4012 2014 AS NZS 4013 2014 PARTICULATE EMISSION FACTOR 0 5g kg C...

Page 5: ...Regency Albany Freestanding Wood Fire 5 DIMENSIONS dimensions ...

Page 6: ...tivity Regency recommends that your unit is secured to the floor by using the bolt down holes inside the pedestal 11 Do not connect this unit to a flue serving another appliance SAFETY GUIDELINES AND WARNINGS 1 Never use petrol petrol type lantern fuels kerosene charcoal lighter fuel or similar liquids to start or freshen up a fire in your heater Keep all such liquids well away from the heater whi...

Page 7: ...8m2 k w for 4mm sheets of cement fibre sheet The flue pipe shall extend not less than 4 6m above the top of the floor protector NOTE Installation must be carried out by a licensed installer in accordance with AS NZS 2918 2001 IMPORTANT 1 The Hawkwind Standard flue kit requires one 130o x 900mm stainless reflective shield between the decromesh casing and ac tive flue 2 The AHD Special Insulated flu...

Page 8: ...tant that you fully understand the operation of your draft control CAUTION THIS APPLIANCE MUST BE MAINTAINEDANDOPERATEDATALLTIMES IN ACCORDANCE WITH THESE INSTRUC TIONS CAUTION THE USE OF SOME TYPES OF PRESERVATIVE TREATEDWOODASAFUEL CAN BE HAZARDOUS WARNING ANY MODIFICATION OF THE AP PLIANCE THAT HAS NOT BEEN APPROVED IN WRITING BY THE TESTING AUTHORITY IS CONSIDERED AS BREACHING AS NZS 4013 WARN...

Page 9: ...ut 10 15 minutes every morning during burning season 2 Burn heater with draft control wide open for about 10 15 minutes every time you apply fresh wood This allows the wood to achieve the charcoal stage faster and burns up any unburned gas vapours which might otherwise be deposited within the system 3 Only burn seasoned wood Avoid burning wet or green wood Seasoned wood has been dried at least one...

Page 10: ...10 Regency Albany Freestanding Wood Fire maintenance Note Thermodisc temp switch in the fan control circuit Heater Thermodisc must come up to operating temperature for fan to operate See page 8 ...

Page 11: ...mbly 12 8010609 Ash Lip Panel 13 6150223 Fan Assembly fan only 14 1141400 Metal lip inside firebox 15 8010115 Glass Retainer Bracket 16 3720101 Door rope seal 5 ft 17 1141004 Rear Baffle Brick Support Bar 18 1211500 Latch Bracket 19 8010614 Hinge Bracket 20 1211201 Inner Back Shield 21 1151700B Air Slide Fasteners 3 pcs 22 8010611 Steel baffie 23 7510206 Cast Plate Set 24 1141704B Friebrick Retain...

Page 12: ...Drawer Heatshields Pedestal 1 All Baffles Steel Ceramic Vermiculite 1 All castings firebox surrounds doors panels etc 1 All Electrical Fans wiring switches etc Fan only 1 Glass Crazing 1 Catalyst Assembly see below for specific details 6 Years Prorated 3 Flue components 1 Firebricks Nil Nil After the original warranty coverage for any of the parts above have expired any repair and or replacement p...

Page 13: ...for results or costs of workmanship of unauthorised FPI dealers or agents in the negligence of their service work Additional service fees may apply if you are seeking warranty service from a dealer other than the dealer from whom you originally purchased the product At all times FPI reserves the right to inspect reported complaints on location in the field claimed to be defective and determine whe...

Page 14: ...ng appliances Any unit showing signs of neglect or misuse will not be covered under the terms of this warranty policy and may void this warranty This includes units with rusted or corroded fireboxes which have not been reported as rusted or corroded within three 3 months of installation purchase Any alteration to the unit which causes sooting or carboning that results in damage to the exterior fas...

Page 15: ...ed to at the option of the supplier one or more of the following i replacement of the goods or the supply of equivalent goods ii the repair of the goods iii the payment of the cost of replacing the goods or of acquiring equivalent goods or iv equivalent goods or v the payment of the cost of having the goods repaired b To the extent that services supplied by the supplier are services other than ser...

Page 16: ...place Products Australia Pty Ltd does not provide installation services Fireplace Products Australia Pty Ltd 1 3 Conquest Way Hallam VIC Australia 3803 Phone 61 3 9799 7277 Fax 61 3 9799 7822 To obtain warranty service in Western Australia and or New Zealand please contact one of our authorised distributors in those areas Western Australia Air Group Australia 28 30 Division St Welshpool WA Austral...

Page 17: ...elow in order for us to serve you better Warranty Registration Form or Register online immediately at the above Web Site Warranty Details Serial Number required Purchase Date required mm dd yyyy Product Details Product Model required Dealer Details Dealer Name required Dealer Address Dealer Phone Installer Date Installed mm dd yyyy Your Contact Details required Name Address Phone Email For purchas...

Page 18: ...18 Regency Albany Freestanding Wood Fire ...

Page 19: ...Regency Albany Freestanding Wood Fire 19 ...

Page 20: ..._________________________ ___________________________________________________________________ Installer ____________________________________________________________ Phone ____________________________________________________________ Date Installed _______________________________________________________ Serial No ___________________________________________________________ ...

Reviews: