1. Introduction 

We would like to congratulate you on the purchase of our compressor. We appreciate your trust. That's why functional 
security and operational safety comes for us first. 
 

2. In general 

Please, follow before you start running the compressor  

1. 

On the upper side of the compressor, you find a white plastic-locking stopper which is inserted in the oil filter 
opening. Remove the locking stopper and substitute it with the red oil filter plug (provided - accessories bag).  

2. 

With the oil stand display in the lower front area of the compressor (directly behind the regulator), the oil stand 
can be controlled. For normal use the oil stand must be at least half fill 

1. 

on the Oil stand display. For re-filling you can use any Compressor oil. 

2. 

On the regulator there are two pressure hose connections. Air amount for one pressure hose connection is used 
by turning the regulator lever handle. The other is a free flow directly from the tank. Screw either a metal cap or 
a quick coupling (not included) on the pressure hose connection with free flow, before you start the compressor. 
To prevent running out, you can use a nylon thread tape. 

 
Operators are on their own responsible for:

 

• 

Following and respecting  the local, regional and national regulations. 

• 

The regulations defined in the operating instructions and tips (laws, orders, directives follow etc.) for a sure and safe 
use and maintenance. 

• 

Make sure that the operating instructions are available to the service and maintenance staff and the tips and warnings 
as well as the safety regulations are obeyed in all details. 

 

3. Ranges of application 

On grounds of their regulation purposes they are set in and used where condensed Air with the normal atmospherical 
compositions are required: 

• 

Working air 

• 

Wind air 

• 

Pumped air 

 
If necessary the generated air pressure is to be processed according to its regulations (filtering, drying): 

• 

Breathing air 

• 

Air in food industry 

• 

Air for ventilating fishponds 

 
The Profi-Air Tec compressors are not allowed to use any other gases except air with the normal atmospherical compositions 

 
4. Preparation and statring  

1. 

The place to set the compressor should be clean, dry and ventilated 

2. 

Keep the use voltage within ± 5% of rated. 

3. 

Keep the oil level in the red circle lever. 

4. 

Recommend compressor oil use SAE30 or L-DAB100 when the indoor temperature is over 10°C and use 
SAE10 or L-DAB68 below 10°C. 

5. 

Open the outlet valve. Set the knob of pressure switch in position on, let the compressore run 10 minutes with 
no load to ensure lubricating the moving parts before regular service. 

6. 

Cheking the tension of V-belt. It is correct when the belt can be depressed downard 10~15mm with fingers by 
the middle of the belt. 

 
5. Operation 

Before using the compressor follow the security tips: 
The compressor may only be started without pressure! 
Please, check before every use the electrical connections as well as the cable for intactness. 
Please, check before the installation whether the electrical connections are earthed according with the legal regulations and 
are installed. 
 
Turning on:     Turn the counter on I 
                        by versions with a pressure switch put the switch toggle on I. 
 
Switch off:      Turn the counter on 0 
                        by versions with a pressure switch put the switch toggle on 0. 
 
 

 

 
1. 

The compressor is controlled by pressure switch when normal working. It can be stopped automatically as pressure 
increasing to the maximum and restart as pressure decreasing to the mnimum. The rated pressure has been adjusted 
when produced. Don’t change it carelessly. As soon as motor switched off the compressed air in the dicharge pipe 
should be released through the release valve under the switch. This is the necessary condition for restart otherwise the 
motor will be damaged. The rated pressure can be adjusted by turning the adjusting bolt of the switch. 

2. 

The output pressure of compressed air can be adjusted by regulating valve. 

3. 

When the running compressor needs be stopped, only set the knob of pressure switch in position off. 

 
A safe use with Profi-AirTec compressors are guaranteed only, when the compressors are used according to their designated 
defined purposes, the relevant security tips are respected and in the operating instructions provided information are applied 
according to the instructions.  
 

ATTENTION: 

Too frequent turning on and off should be absolutely avoided, 

because otherwise, the condensers and the engine winding will be damaged. 
 

6. Security tips 

1. 

Absolutely follow and obey valid regulations on the electrical security  

2. 

The compressors may not be used nearby ignitable liquids. 

3. 

The compressors may not be used in sprinkle water areas. 

4. 

Always use protective glasses. 

5. 

Before each work on the compressor, it must be switched off and be taken from the electricity source (To be done only 
from a professional!) 

6. 

Before working on the commpressor it has to be free/empty of pressure! 

7. 

It may not suck in dust or overspray. 

8. 

The suction filters are regularly to be clean (when necessary) to avoid damages on the compressor. 

9. 

Never use the compressor without a suction filter. 

10. 

It is to be avoided that the air sucked in by the compressor does not have contact with explosion-threatened gases or 
dust 

11. 

The compressor may not be used in humid rooms. 

12. 

Sluggish fuse protection must be used. 

13. 

The changing of filters and O rings are to be carried out as instructed or possibly in a service center 

14. 

The compressors stand under overpressure,  injury danger exists by air pressure exhaustion. 

15. 

The compressor may only be started without pressure. 

16. 

The surrounding temperature should be max. 35°C and min 10°C. 

 
The Manufacturer explains: 

• 

To take over no responsibility in case of accidents or damages on the basis of carelessness or disregard to the 
instructions in this book 

• 

to reject every responsibility for damages which originate from the improper use of the compressors 

 

7. Cautions 

1. 

Put the cover off first and put on the breath pipe and air filter before the compressor run. 

2. 

Never unscrew any connecting part when the tanks is in pressure condition. 

3. 

Never disassemble any electrical part before disconnecting the plug. 

4. 

Never adjust the safety valve carelessly. 

5. 

Never use the compressor in place where voltage is too low or too high. 

6. 

Never use electric wire which is longer than 5 m. 

7. 

Never disconnect the plug to stop compressor, set the switch knob in position off instead. 

8. 

If the release valve doesn’t work as motor stopped, find the cause immediately so as not to damage motor. 

9. 

Lubricating oil must be clean, oil level should be kept in the red circle of leveler 

10. 

Disconnect the plug to cut off power supply and open the outlet valve. 

 
 
 
 
 
 
 

 

ENGLISH

ENGLISH 

Summary of Contents for Profi-AirTec 128-8-1.1

Page 1: ... 5 Profi AirTec 670 8 5 3 P AT380 8 2 5 P AT670 8 5 3 Profi AirTec 1050 12 7 0 P AT1050 12 7 0 Contents English 1 6 Deutsch 7 11 1 Introduction 2 2 In general 2 3 Ranges of application 2 4 Preparation and statring 2 5 Operation 2 3 6 Security tips 3 7 Cautions 3 8 Maintance 4 9 Electric principle wiring diagram 4 10 Guarantee regulations 5 11 Troubleshooting 5 12 Technical Data 6 ENGLISH 1 ...

Page 2: ...ggle on 0 1 The compressor is controlled by pressure switch when normal working It can be stopped automatically as pressure increasing to the maximum and restart as pressure decreasing to the mnimum The rated pressure has been adjusted when produced Don t change it carelessly As soon as motor switched off the compressed air in the dicharge pipe should be released through the release valve under th...

Page 3: ...ly informed service staff By use of not original spare parts The operator has to provide on his own responsibility for The security regulations are kept A not designated use as well as a faulty installation or inadmissible usage are excluded and that a designated use is guaranteed when the compressor is used according to the by contract agreed application terms Moreover we perform no compensation ...

Page 4: ...stung Anzahl Zylinder Motordrehzahl Spannung Stromstärke Schutzart Isolationsklasse Schallleistungspegel Kabellänge English Engine power Tank size Max pressure Max air pressure output Number of cylinders Engine speed rpm Tension Amperage Protective class Isolation class Noise level Cable length Engine power Tank size Max pressure Max air pressure output Number of cylinders Engine speed Tension Amp...

Page 5: ...chalter schaltet den Motor automatisch aus wenn der maximaler Druck erreicht wird und startet den Motor neu wenn der minimaler Druck erreicht wird Der Nenndruck wurde in Produktionsprozess angepasst Verändern Sie die Einstellung nicht nachlässig Sobald der Motor abgeschaltet wird sollte die Druckluft in die Druckleitung durch das Ventil freigegeben werden Dies ist die notwendige Voraussetzung für ...

Page 6: ...satzteilen Der Betreiber hat in eigener Verantwortung dafür zu sorgen dass die entsprechenden Sicherheitsbestimmungen eingehalten werden dass eine nicht bestimmungsgemäße Verwendung sowie eine fehlerhafte Aufstellung oder Inbetriebnahme und ein unzulässiger Betrieb ausgeschlossen sind und dass darüber hinaus eine bestimmungsgemäße Verwendung gewährleistet und der Kompressor entsprechend den vertra...

Reviews: