Electrical Connections
High Voltage Power Connections
The Evergreen EM is designed for continuous un-switched connection to
its rated high voltage power supply. Motor operation is controlled by low
voltage signal inputs.
Always confirm the rating on the motor matches the power supply of the
system it is applied to and/or the motor it is replacing.
If a door safety switch is present, wire after the switch so power will be
disconnected when the door is removed for maintenance or service.
1. Using 3/16” Female Quick Connect Terminals and 18 AWG wire, connect
the (L) and (N) terminals on the motor to any un-switched line voltage L1
and L2, Nameplate Voltage power supply.
2. Using a 3/16” Female Quick Connect Terminal and 18 AWG wire,
connect the (G) terminal on the motor to the system ground.
Always disconnect the main power from the unit being serviced before
making any wiring connections to the Evergreen EM. It is also a good
practice to confirm that the power is off with a meter.
®
EM