The glow plug’s coil must be pulled down(use a straight pin to pull the coils out) and exposed to install
into the engine.
3.8 Gas & fuel solenoid valves (full auto)
Connect fuel solenoid valve to the fuel line in between the engine and fuel pump. Connect
gas solenoid valve to gas line in between the engine and the propane source.
4. Programming of the FADEC.
The programming of the FADEC can be done from the terminal of hand or the PC. In any case the
parameters to program are such and with such values.
FADEC programming parameters
Parameter
Function
Thrust 10-14 lbs
Thrust 18-22 lbs
Full throttle
RPM
Fits the maximum rpm that will reach the engine with the
throttle control to 100%
160000 rpm
115000 rpm
Idle RPM
Fits the rpm in idle.
42000 rpm
32000 rpm
Stop RPM
Fits the minimum rpm to which the motor can work. If the
rpm is lower, the FADEC will stop the engine.
24000 rpm
20000 rpm
Start/Min.
Temperature
Minimum temperature to which the engine can work. In
phase of starting, the FADEC will begin to provide fuel. In
phase of running, it will stop the engine if the read
temperature is inferior to this.
0-999 ºC
100ºC
0-999 ºC
100ºC
Max.
Temperature
Maximum Temperature of operation of the engine. The
FADEC will try to maintain the temperature below this
value, arriving to stop the motor in case of not obtaining .
0-999 ºC
860ºC
0-999 ºC
900ºC
Acceleration
delay
This parameter allows to fit the time of acceleration of the
engine. To greater value, more slowly it will respond the
engine. The time of total acceleration is not fixed, since it
depends on other parameters as they are the
temperature and the present rpm.
0-255
20
0-255
20
Deceleration
delay
Just as the acceleration delay, this parameter allows to
define the time of deceleration. This parameter must be
increased if the motor tends to extinguish itself when
going abruptly from maximum power to the idle.
0-255
15
0-255
15
Stability delay This parameter allows to stabilize the power once this
has arrived at the value set with the throttle control. The
value must be increased if the power is not stable
0-255
50
0-255
43
Pump start
point
The values of “pump start point” from 0-8 in a auto mode
Will adjust itself pump power start it slowly.
0-255
Auto+2
0-255
Auto+2
Start Ramp
Fits the increase of fuel flow during the start phase. To
greater value, more quickly the motor will accelerate until
the idle
0-255
002
0-255
002