Adjustment of limit positions:
Position switch S3 is adjusted to specified stroke.
Limit position switches are adjusted with accuracy ± 0,5 mm referring to lower position and stroke.
Additional position switches are adjusted 1mm before end positions.
Setting of thrust switches
Switching thrust is set to the rated thrust with tolerance of
±
10 %.
Switching thrust is not adjustable.
1.8.2 Mechanical connection:
•
flange (DIN 3358)
•
pillars
Basic and connecting dimensions are given in dimensional drawings.
1.8.3 Electric connection
with terminal board (X):
•
max. 12 terminals, nominal connecting cable size 1,5 mm
2
, max. 2,5 mm
2
(for
ST
)
•
12 terminals, nominal connecting cable size 1.5 mm
2
, max. 2,5 mm
2
+ 5 terminals, connection
size max. 0.5 mm
2
(for
STR
)
•
3 cable glands - cable diameter from 6 up to 10,5 mm
When using two types of extended cable glands - cable diameter from 9 up to 13 mm (max for 2
positions, without combination with cable glands from 14 to 18 mm) resp. from 14 to 18 mm (just for
one position).
with protection terminal:
external and internal, mutually connected and marked with protection earthling mark
Electric connection - according to wiring diagrams.
1.9 Conservation, packing, transport, storing and unpacking
Surfaces without surface treatment are treated by conservation preparation MOGUL LV 2-3
before packaging .
Conservation is not necessary if the following storage conditions are complied with:
• Storage temperature: -10 to +50 °C
• Relative air humidity max.80 %
• Electric actuators and their accessories must be stored in dry, well ventilated covered spaces,
protected against impurities, dust, soil humidity (by placement to racks, or on palettes), chemicals
and foreign interventions
• There shall be no corrosive gases present in the storage areas.
The EA are delivered in solid packages guaranteeing resistance in accordance with EN 60 654
(IEC 60 654-1 and IEC 60 654-3).
Package is a box. Products in boxes is possible to load on the pallets (pallet is returnable). On
the outer side of the package is stated:
•
manufacturer label,
•
name and type of product,
•
number of pieces,
•
other data – notices and stickers.
The forwarder is obliged to secure packed products, loaded on transportation means, against
self-motion; if open transportation means are used, to secure their protection against atmospheric
precipitations and splashing water. Displacement and securing of products in transportation means
must provide their stable position, exclude the possibility of their inter-collision and their collision with
the vehicle walls.
They can be transported in unheated and not airtight areas of transport means with effects in range:
Summary of Contents for ST 0
Page 26: ...24 ST 0 STR 0 6 Enclosures 6 1 Wiring diagrams Wiring diagrams for EA ST...
Page 29: ...ST 0 STR 0 27 Flange DIN 3358...
Page 30: ...28 ST 0 STR 0 Pillars...
Page 31: ...ST 0 STR 0 29 Flange...
Page 32: ...30 ST 0 STR 0 Flange...
Page 33: ...ST 0 STR 0 31 Flange...
Page 34: ...32 ST 0 STR 0 Pillars...
Page 35: ...ST 0 STR 0 33 Flange...
Page 36: ...34 ST 0 STR 0 Pillars...
Page 37: ...ST 0 STR 0 35 Flange...
Page 38: ...36 ST 0 STR 0 Flange...
Page 39: ...ST 0 STR 0 37...
Page 40: ...38 ST 0 STR 0...