background image

Safety 

 

 

 

6 —  English  

Reflex ex separator — 21.11.2016 

 

 

 
 

1.5

 

Inadmissible operating conditions 

 

The device is not suited for the following conditions. 

 

In drinking water systems 

 

Outdoor operation 

 

Usage with mineral oils 

 

Usage with flammable media 

 

For the use with distilled water 

 

For use with foam-forming substances because this may compromise operation of the vent and result in leaks. 

 

For use with additives in a concentration above the permissible dosing quantity 

 

For use with chemical substances, for which no compatibility tests have been performed for all materials present in the system 

 

For use with water with a glycol content of greater than 50% 

 

 

1.6

 

Residual risks 

 

This device has been manufactured to the current state of the art. However, some residual risk cannot be excluded. 

 

 

 

WARNING

 

 

Risk of injury due to heavy weight 

The devices are heavy. Consequently, there is a risk of physical injury and accidents. 
–   Use suitable lifting equipment for transportation and installation. 

 

 

 

 

 

CAUTION

 

 

Risk of burns 

High media and surface temperatures in heating systems can cause burns to the skin. 

 

Allow the system to cool before working on the device. 

 

Maintain a sufficient distance from escaping medium. 

 

Wear suitable personal protective equipment (safety gloves and goggles). 

 

Please place appropriate warning signs in the vicinity of the device. 

 

 

 

 

CAUTION

 

 

Risk of injury due to pressurised liquid 

If installation, removal or maintenance work is not carried out correctly, there is a risk of burns and other injuries at the connection 
points, if pressurised hot water or hot steam suddenly escapes. 

 

Ensure proper installation, removal or maintenance work. 

 

Ensure that the system is de-pressurised before performing installation, removal or maintenance work at the connection points. 

 

 

 

 

Cooke Industries - Phone: +64 9 579 2185    Email: [email protected]    Web: www.cookeindustries.co.nz

Summary of Contents for Exdirt

Page 1: ...separator 21 11 2016 Exvoid Exvoid HC HiCap Exdirt Exdirt HC HiCap Extwin Extwin HC HiCap GB Operating manual Cooke Industries Phone 64 9 579 2185 Email sales cookeindustries co nz Web www cookeindust...

Page 2: ...Cooke Industries Phone 64 9 579 2185 Email sales cookeindustries co nz Web www cookeindustries co nz...

Page 3: ...7 2 2 Optional equipment 7 2 2 1 Sludge separator 7 2 3 Identification 8 3 Technical data 8 4 Installation and assembly 9 4 1 Notes 9 4 2 Space requirements 9 4 3 Exvoid 10 4 4 Exdirt 10 4 5 Extwin 10...

Page 4: ...ies CAUTION Damage to health The sign in combination with the signal word Caution indicates danger failure to observe the safety information can result in minor reversible injuries ATTENTION Damage to...

Page 5: ...nual and the safety information in particular may cause the destruction and defects of the equipment endanger persons and adversely affect the functioning Any contravention voids the guarantee and lia...

Page 6: ...vices are heavy Consequently there is a risk of physical injury and accidents Use suitable lifting equipment for transportation and installation CAUTION Risk of burns High media and surface temperatur...

Page 7: ...dge particles The device is available in the following variants No Variant 1 Welded connection 2 Flange connection 1 3 Welded connection and service flange 2 3 Flange connection and service flange 2 1...

Page 8: ...cturing Serial no Serial number Art No Article number 3 Technical data Note The following values apply for all standard separators Max temperature 0 110 C Max pressure 10 bar Special versions accordin...

Page 9: ...ice is not a load bearing structural element By default the calculation of the vessels does not take lateral acceleration forces into account Avoid alternating stresses such as pressure shocks abrupt...

Page 10: ...y valve bottom part on the top side of the separator Maintain the large vent freely opened Installation of the Exferro magnetic insert on the bottom side of the separator First insert the Exferro comp...

Page 11: ...eople enter the sphere of influence of magnets The time intervals for maintenance work depend on the specific operating conditions 5 1 Pressure test During a hydraulic pressure test the pressure must...

Page 12: ...diagonally and step by step as per the state of the art 5 2 3 Sludge separator with magnet insert CAUTION Restriction during operation in respect of medical devices due to magnetic field The device co...

Page 13: ...of the product described above with the provisions of the applied Directive s is demonstrated by compliance with the following standards regulations Pressure Equipment Directive AD 2000 according to n...

Page 14: ...Cooke Industries Phone 64 9 579 2185 Email sales cookeindustries co nz Web www cookeindustries co nz...

Page 15: ...1000 2580 671 A 600 DN600 PN16 1530 1630 1200 3020 832 Exvoid HiCap 1 mm m3 h L mm 2 mm H mm HM mm A 60 3 HC 60 3 25 260 132 810 153 A 76 1 HC 76 1 40 260 132 810 163 A 88 9 HC 88 9 54 370 206 965 159...

Page 16: ...6 1530 1630 1200 2960 840 1 mm m3 h L mm 2 mm H mm HM mm D 60 3 R 16 0 60 3 12 5 260 132 521 165 D 76 1 R 23 0 76 1 20 260 132 521 175 D 88 9 R 32 0 88 9 27 370 206 636 170 D 114 3 R 37 0 114 3 47 370...

Page 17: ...600 PN16 3000 1630 1200 3250 840 1 mm m3 h L mm 2 mm H mm HM mm D 60 3 R HC 60 3 25 260 132 706 165 D 76 1 R HC 76 1 40 260 132 706 175 D 88 9 R HC 88 9 54 370 206 861 170 D 114 3 R HC 114 3 94 370 20...

Page 18: ...0 1630 1200 4100 2007 2093 1 mm m3 h L mm 2 mm H mm HM1 mm HM2 mm TW 60 3 R 13 0 60 3 12 5 260 132 785 335 450 TW 76 1 R 13 0 76 1 20 260 132 785 335 450 TW 88 9 R 46 0 88 9 27 370 206 940 413 527 TW...

Page 19: ...16 3000 1630 1200 5800 2857 2943 1 mm m3 h L mm 2 mm H mm HM1 mm HM2 mm TW 60 3 R HC 60 3 25 260 132 1050 468 582 TW 76 1 R HC 76 1 40 260 132 1050 468 582 TW 88 9 R HC 88 9 54 370 206 1285 585 700 TW...

Page 20: ...00 600 700 Exdirt R Exdirt R HC Extwin R Extwin R HC 82522xx 82524xx 82532xx 82534xx mm HiCap mm mm HiCap mm DN 50 DN 65 60 3 76 1 300 570 370 640 DN 80 DN 100 88 9 114 3 400 660 550 900 DN 125 DN 150...

Page 21: ...Cooke Industries Phone 64 9 579 2185 Email sales cookeindustries co nz Web www cookeindustries co nz...

Page 22: ...eflex Winkelmann GmbH Gersteinstra e 19 59227 Ahlen Germany Telephone 49 0 2382 7069 0 Fax 49 0 2382 7069 588 www reflex de Cooke Industries Phone 64 9 579 2185 Email sales cookeindustries co nz Web w...

Reviews: