Rev 3.1
33 | P a g e
5
Handling & Storage
5.1
Stock Inspections
Before entering service your new FROG-XT4 needs to be inspected to ensure that fit for use
and to make sure that there is as much time as possible available on the certification. These
guidelines are
NOT
applicable to units and parts that have already been put into service.
Storage Actions
i.
Remove lifting assembly from unit
ii.
Place all items into clean dry storage
iii.
Remove any lifting assembly covers
iv.
Chock up unit to prevent foot damage
In Stock Inspections
–
You should follow the below table for any carriers or replacement
parts that are held in storage.
Type
In Stock Visual Inspection
Shelf Life
Transfer capsules
1 Year
5 Years
Wire Rope Lifting
Assembly
6 months
2 Years
Other replacement
Parts (not lifting
assemblies)
None
NA
Prior to First Use
- You should follow the below table before using your equipment for the
first time.
Type
Transfer carriers
Wire Rope Lifting
Assembly
Replacement
Parts
Visual Inspection
Yes
Yes
Yes
Load Test & Post
Load Test Visual
Inspection
<2year old = No
>2year old = Yes
No
No
Update Data Plate
Yes
NA
NA
Update Certificates
Yes
Yes
No
Certificate of
Thorough
Examination
No
Yes
No
Stamp Entry into
Service Date
Yes
No
No