SAFETY RELAY 

AD SR0 

INSTALLATION USE AND MAINTENANCE 

 

 

This symbol indicates an important personal safety warning. Failure to comply with the 
warning may result in very high risk for exposed personnel. 

 

INTRODUCTION 

The AD SR0 is an accessory device for the interconnection of a photoelectric light 
curtain in a safety circuit. See details below about light curtain models, wiring, etc. 

 

 

When deciding on the safety category to be adopted, carefully consider  the risks analysis 
of the machine. 

 

The module has been designed in particular for use with the R

EE

R light curtains of the 

Admiral AX (category 4), Vision VX and Vision VXL/MXL (category 2) series. Consult R

EE

before using the interface with other light curtain models or safety devices. 

 

For safe use of the device, it is essential to read and understand the contents of this 
handbook.  

 

Failure to comply with the prescriptions indicated in this notice may result in very high 
risks for the operating personnel of the protected machine. 

 

INSTALLATION AND ELECTRICAL CONNECTIONS 

 

Install the AD 

SR0 safety 

relay in an environment with a protection rating of at 

 

least IP54. 

 

The AD SR0 safety relay must be supplied with a 24Vdc 

±

20% power supply. 

 

The external power supply must comply with the standard EN 60204-1. 

 

ELECTRICAL CONNECTIONS 

The safety relay is equipped with three terminal boards for the connections to the light 
curtain and to the machine. 

 

 CJ3 

CJ2 

CJ1 

Figure 1 

 

Summary of Contents for AD SR0

Page 1: ...ory 4 Vision VX and Vision VXL MXL category 2 series Consult REER before using the interface with other light curtain models or safety devices For safe use of the device it is essential to read and un...

Page 2: ...3 0VDC 0Vdc Power Supply 4 IN2 Light curtain static output 5 IN1 Light curtain static output CJ2 CJ3 PIN NOME PIN NOME 6 N O contact 9 N O contact 7 N O contact 10 N O contact 8 N C contact 11 N C con...

Page 3: ...ht curtain in AUTOMATIC operatione mode Example of connection of the AD SR0 module with AX VX VXL safety light curtain in MANUAL operatione mode Connection of VXL Emitter modification of the above sch...

Page 4: ...2011 Rev 10 11 Example of connection of the AD SR0 module with MXL safety light curtain in AUTOMATIC operatione mode Example of connection of the AD SR0 module with MXL safety light curtain in MANUAL...

Page 5: ...20 Aprile 2011 Rev 10 Example of connection of the AD SR0 module with EOS4X safety light curtain in AUTOMATIC operatione mode Further details regarding connections can be found on each curtain techni...

Page 6: ...tions of more than 50m cables with a cross section of at least 1mm2 must be used It is good practice to separate the power supply of the safety relay from that of other electrical equipment electrical...

Page 7: ...aintenance Repairs modifications adaptations not carried out by REER personnel tampering etc Accidents or impacts also due to transportation or causes of force majeure Other causes not to be ascribed...

Page 8: ...seguenti Direttive Europee declares that the AD SR0 and AD SR0A Safety Interfaces comply with the following European Directives 2006 42 CE Direttiva Macchine Machine Directive 2004 108 CE Direttiva Co...

Page 9: ...16 8540554 20 Aprile 2011 Rev 10 REER S p A 32 via Carcano 10153 Torino Italia Tel 39 0112482215 r a Fax 39 011859867 Internet www reer it e mail info reer it...